| 90-0010-10 |
3600
Single Shelf or 3600 multi-shelf system peripheral unit is compatible with
either AC power supplies (90-9524-01) and trays (90-3669-11 single feed, or
90-3669-12 dual feed) or DC power supply (90-9524-02) and trays (90-3669-03).
The shelf has 8 universal card slots for various resource and line cards,
plus the capacity to support redundant power and control.. |
REQUEST QUOTE |
| 90-0010-13 |
3600 Single Shelf or 3600 multi shelf with rear access to all
shelf connections and compatible only with the -48/60V DC Power supply
(90-9524-02) and tray (90-3669-03). Provides backplane access to a total of
eight Universal Card Slots. Includes backplane, cardfile and GFC filler
plate. Requires new Balanced Transceiver Cards and Cables (90-0090-06 and
90-0090-07) when configured for dual shelf and/or control redundancy
operation. Meets Class B EMC requ irements. This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0010-14 |
3600 Single shelf or 3600 multi shelf with rear access to all
shelf connections and compatible only with the AC power supply (90-9524-01)
and tray (90-3669-11). Provides backplane access to a total of eight
Universal Card Slots. Includes backplane, cardfile an GFC filler plate.
Requires new Balanced Transceiver Cards and Cables (90-0090-06 and
90-0090-07) when configured for dual shelf and/or control redundancy
operation. Meets Class B EMC requirements |
REQUEST QUOTE |
| 90-0029-01 |
This card consists of 12 individual Loop Start, Ground Start or
Private Line Automatic Ringdown (PLAR) circuits designed to interface with
PBX trunk ccts or standard telephones. FXS, DPO, and MFO signalling is
supported. Provides A law companding on all circuits for the UK and
international m arkets. Transmit gain range is 4 to -3 dBm and receive gain
range is 1 to -6 dBm. |
REQUEST QUOTE |
| 90-0029-05 |
This card consists of 12 individual Loop Start, Ground Start or
Private Line Automatic Ringdown (PLAR) circuits designed to interface with
PBX trunk ccts or standard telephones. FXS, DPO, and MFO signalling is
supported. Provides A law companding on all circuits for the UK and
international m arkets. Transmit gain range is 4 to -3 dBm and receive gain
range is 1 to -6 dBm. Designed for International Markets with 600½ resistive
interface. |
REQUEST QUOTE |
| 90-0030-01 |
This card consists of 12 individual Loop Start, Ground Start or
Private Line Automatic Ringdown (PLAR) circuits designed to interface with
PBX trunk ccts or standard telephones. FXS, DPO, and MFO signalling is
supported. Provides A law companding on all circuits for the UK and
international m arkets. Transmit gain range is 4 to -3 dBm and receive gain
range is 1 to -6 dBm. Provides for Mu Law voice companding. Designed for the
North American market requirements. |
REQUEST QUOTE |
| 90-0030-03 |
This card consists of 6 individual Loop Start, Ground Start or
Private Line Automatic Ringdown (PLAR) circuits designed to interface with
PBX trunk ccts or standard telephones. FXS, DPO, and MFO signaling is
supported. Provides Mu-law companding on all circuits for the North American
market. Allows for transmit and receive gain ranges of 0 to -7 dBm. The input
impedance presented is 900 ohms + 2.16uF. BC-Tel special design. |
REQUEST QUOTE |
| 90-0031-04 |
This data card provides six CCITT X.21 interfaces. Two of the
six interfaces are presented on the faceplate of the card via a 25 pair AMP
CHAMP connector. The remaining four interfaces are available at the backplane
connectors. This card also supports a subset of RS-449. |
REQUEST QUOTE |
| 90-0032-06 |
This card offers six CCITT V.35 interfaces. Three of the
circuits are available at the backplane connector and three others are
available on the card's faceplate connector (AMP CHAMP). This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0035-05 |
System expansion card, allows for a 6 UCS single shelf system to
expand to a 16 slot double shelf system capable of 3.840 Mb/s (60 DS0) of
bandwidth per card slot. Requires a second shelf, second power supply and the
appropriate intershelf cabling to complete the expansion. This card is
supported by Generic 1113 or greater. (Includes 90-0075-02) Expander Module
(16+). |
REQUEST QUOTE |
| 90-0038-09 |
Special applications card which consists of 6 Digital Signal
Processor (DSP) circuits (4 of which reside on the 90-0294-04 module
included). 8 and 16 KBPS HCV voice compression and DDS/X.50 sub-rate
multiplexing are some of the applications supported by this card. |
REQUEST QUOTE |
| 90-0038-11 |
Special applications card which consists of 6 Digital Signal
Processor circuits (DSP). This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0038-19 |
DSP Resource card
supporting 20 HCV resources, 10 LD-CELP channels or 20 A-CELP(G.729 and
G.729A) channels as well as fax and V.32/V.32bis modem speeds up to 14.4kb/s.
The card also supports VoFR, and is software upgradeable to support future
algorithms as developed. |
REQUEST QUOTE |
| 90-0043-03 |
This card consists of 6 individual RS232/CCITT V.24 compatible
interfaces. Three of the interfaces are available from the backplane with the
remaining three available at the front panel 25 pair connector (AMP CHAMP). |
REQUEST QUOTE |
| 90-0060-01 |
This package includes six card slot filler plates. These are
used to maintain cooling requirements for partially filled 3600 shelves or
3645 peripheral shelves. |
REQUEST QUOTE |
| 90-0060-03 |
This package includes six slot filler plates for the 3600
Switching Shelf (90-0662-01/03). These are used to maintain cooling
requirements for partially filled Switching Shelves. |
REQUEST QUOTE |
| 90-0060-08 |
This package contains eight full height and eight half height
slot-filler plates for the 3600 High Speed Peripheral Shelf-2 (90-0652-02).
These are used to maintain cooling requirements for partially filled High
Speed Peripheral Shelf-2's. |
REQUEST QUOTE |
| 90-0060-09 |
This filler plate is intended for use in Single Shelf Redundant
applications and is to be installed in Slot 10. |
REQUEST QUOTE |
| 90-0060-10 |
A single filler plate used in place of the GFC-2 card in slot
12. This filler plate is used to maintain cooling requirements for partially
filled 3600 shelves. This plate can be used for either EMC or non-EMC
shelves. |
REQUEST QUOTE |
| 90-0075-02 |
Expansion module required by the Expander Card (90-0035-0x) when
card slot bandwidth greater than 1.920 Mb/s (30 DS0) is required. This module
will allow Generic 1113 or greater systems equipped with Control Card 2
(90-0050-04), an expansion capability of up to 16 slots, each capable of
providing 3.830 Mb/s (60DS0) of bandwidth. |
REQUEST QUOTE |
| 90-0077-04 |
This General Facilities card allows for order wire access,
diagnostics, and alarming. Order wire facility offers A-Law companding, and
alarming facility is according to BT TEP-1E. Offers a reduced width faceplate
with card extraction levers. |
REQUEST QUOTE |
| 90-0077-05 |
This assembly is a variant of the 90-0077-06 providing enhanced
alarm I/0 capabilities (Alarm Module 2). Meets Class B EMC. |
REQUEST QUOTE |
| 90-0077-07 |
Similar to 90-0077-05, but tailored for Siemens. |
REQUEST QUOTE |
| 90-0078-04 |
This General Facilities card supports the same functionality as
90-0078-03 but offers a reduced width faceplate with card extraction levers.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-0078-06 |
Identical to 90-0078-04, but with enhanced alarm I/O
capabilities (Alarm Module 2). |
REQUEST QUOTE |
| 90-0079-03 |
This card consists of six E<(>&<)>M interface
circuits software configurable for 2 wire (ZCO) or 4 wire (600 ohms)
transmission. Type V signalling and A-law voice companding are supported.
This card also includes modified gain selections supported by generic 1113 or
greater. |
REQUEST QUOTE |
| 90-0079-04 |
This card consists of six E<(>&<)>M interface
circuits for 2 or 4-wire transmission. Type V signalling and A-Law voice
companding are supported. A line impedance of 600is supported for both 2-wire
and 4-wire operation. This card also includes modified gain selections
supported by generic 1113 or greater. |
REQUEST QUOTE |
| 90-0079-05 |
This card consists of six E<(>&<)>M interface
circuits for 2 or 4-wire transmission. Type V signalling and A-Law voice
companding are supported. The line impedance is 600+ 2.16uF for 2-wire and
600for 4-wire operation. This card also includes modified gain selections
supported by generic 1113 or greater. |
REQUEST QUOTE |
| 90-0079-06 |
This card consists of six E<(>&<)>M interface
circuits for 2 or 4-wire transmission. Type V signalling and Mu-Law voice
companding are supported. The line impedance is 600+ 2.16uF for 2-wire and
600for 4-wire operation. This card also includes modified gain selections
supported by generic 1113 or greater. Intended for the Japanese market. |
REQUEST QUOTE |
| 90-0090-02 |
Included in this kit are one Upper Balance Transceiver Card, one
Lower Balance Transceiver Card and two inter-shelf cables. When using
90-0010-04/05/07/10 Single Shelves, two 90-0090-02 kits are used to provide
redundancy in dual shelf redundant systems. |
REQUEST QUOTE |
| 90-0090-05 |
This assembly includes all the components required to
interconnect two 8 UCS Single Shelves (90-0010-04/05/07/10) in a redundant
capacity (i.e. two sets of Upper and Lower Balance Transceiver cards and four
intershelf cables). This assembly can also be used for 6 UCS Single Shelf
applications when the Dual Shelf Cable Assy Adaptor (90-1064-01) is also
used. The 90-0090- 02 assembly can be used in non-redundant 8 UCS
applications or as replacement parts for the 90-0090-05 assembly. |
REQUEST QUOTE |
| 90-0090-06 |
Included in this kit are one Upper Balanced Transceiver-2 Card,
one Lower Balanced Transceiver-2 Card and one intershelf cable. To be used
with the BT-2 Carrier Assy (90-0090-07) and the 90-0010-13/14/15 EMC/23 inch
Single Shelves. One kit provides non-redundant dual shelf capability while
two kits provide redundant capability. |
REQUEST QUOTE |
| 90-0090-07 |
Included in this kit are two BT-2 Carrier cards and two
half-height filler plates (one Upper and one Lower). Required for the
installation of either one (for non-redundant, dual shelf) or two (for
redundant, dual shelf) BT-2 Card/Cable Kit (90-0090-06) in 90-0010-13/14/15
EMC/23 inch Single Shelves. |
REQUEST QUOTE |
| 90-0091-06 |
This card consists of six E&M interface circuits software
configureable for 2 wire (600 ohm + 2.16 uF) or 4 wire (600) transmission.
Type I, II, or III signalling and Mu-law voice companding are supported. This
card includes modified gain selections. |
REQUEST QUOTE |
| 90-0093-05 |
This product is used with the 3600 Mainstreet. Provides a single
T1 interface conforming to PUB 43801 and 62411. Requires LIM Module
(90-0567-01) for DSX-1 interface or CSU module (90-0161-02) for direct
connection to T1 circuit. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0156-02 |
Single FXS(LGS) module for end-to-end or corporate network
connections interfacing to North American voice terminal equipment with TLP's
for receive and transmit of 0 to -7DB; module operates as FXS or PLAR
circuit. |
REQUEST QUOTE |
| 90-0156-05 |
Single FXS (LGS) module for general applications interfacing to
European and International voice terminal equipment with TLP's for receive
and transmit of 0 to -7DB; module provides line reversal capability. |
REQUEST QUOTE |
| 90-0156-06 |
Single FXS (LGS) module for termination of North American public
network services such as UltraWATS, SDN, Megacom and VPN series offering
TLP's of -3 to -10DB for receive and +4 to -3DB for transmit. Module operates
as FXS or PLAR circuit. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0156-07 |
Single FXS (LGS) module for termination of North American public
network services such as UltraWATS, SDN, Megacom and VPN series offering
TLP's of -3 to -10DB for receive and +4 to -3DB for transmit; this module
provides line reversal capability and increased loop performance. Module
operates as FXS, PLAR or DPO circuits. Recommended for all new installations. |
REQUEST QUOTE |
| 90-0156-08 |
Single FXS module for termination of North American public
network services such as UltraWATS, SDN, Megacom and VPN series offering
TLP's of -3 to -10DB for receive and +4 to -3DB for transmit; this module
provides line reversal capability and increased loop performance. Module
operates as FXS, PLAR or DPO circuits. Module offers complex impedance of 600
+2.15 microfarad and supports on-hook calling line ID. Recommened for new
installations. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-0157-01 |
Single E<(>&<)>M module for end-to-end or
corporate network connections interfacing to North American voice terminal
equipment with TLP's for receive and transmit of +4.0 to -3.5DB. Extended
TLP'S are available in 4 wire mode; receive: +11 to +3.5DB, transmit: -12 to
-19.5 DB, module employs Type 1 or Type 2 signalling. |
REQUEST QUOTE |
| 90-0157-02 |
Single E<(>&<)> M module for general
applications interfacing to European and International voice terminal
equipment with TLP's for receive and transmit of +4.0 to -3.5 DB. Extended
TLP'S are available in 4 wire mode; receive: +11 to +3.5DB, transmit: -12 to
-19.5 DB, module employs Type 1 or Type 2 signalling. (Type 2 signalling is
supported by a special wiring configuration that requires separate external
48VDC source). |
REQUEST QUOTE |
| 90-0157-03 |
Single E&M module for termination of North American public
network services such as UltraWATS, SDN, Megacom and VPN series offering
TLP's of -3 to -10.5DB for receive and +4 to -3.5DB for transmit. Extended
TLP'S are available in 4 wire mode; receive: +11 to +3.5DB, transmit: -12 to
-19.5 DB. Module employs Type 1 or Type 2 signalling. This assembly contains
a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0157-04 |
Single E<(>&<)> M module for general
applications interfacing to European and International voice terminal
equipment with TLP's for receive and transmit of +3.5DB to -3.5DB; module
employs Type 5 signalling. |
REQUEST QUOTE |
| 90-0160-01 |
One per system required for DDS DS0A rate adaption of data
channels connected over 275x MainStreet Data Termination Units; OCU modules
(90-0693-01) do not require this module; module also generates ringback tone
for Megacom800 applications; module is mutually exclusive with the Tone
module (90-0512-01 and 90-0512-02) and any DSP module. |
REQUEST QUOTE |
| 90-0161-02 |
Required for compliance to PUB-62411. Required to connect direct
to T-1 lines from carrier; powered from system only; no wetting current;
includes circuitry for bypass switching; does not include circuitry for
redundancy switching. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0161-02 |
Required for compliance to PUB-62411. Required to connect direct
to T-1 lines from carrier; powered from system only; no wetting current;
includes circuitry for bypass switching; does not include circuitry for
redundancy switching. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0338-04 |
A pair of brackets that will allow a 3612, 3624,or 3630 system
(90-0575-68, 90-0411-57,90-0411-58, 90-0412-52,90-0412-58, 90-2002-04, and
90-2003-03) to be wall mounted. |
REQUEST QUOTE |
| 90-0343-03 |
This card consists of six loop or ground start exchange circuits
designed to interface to central office subscriber trunks or PBX lines.
Compatible with FXO circuits and A-law voice companding. Provides for gain
selection in 1/2 dB steps and software selectable interface impedances of
complex or 600½ when used in generic 1113 or greater. |
REQUEST QUOTE |
| 90-0343-05 |
This card consists of six loop or ground start exchange circuits
designed to interface to central office subscriber trunks or PBX lines.
Compatible with FXO circuits and Mu-law voice companding. All ows for a
transmit gain range of 0.5 to -7 dBm and a receive gain range of 1 to 14.5
dBm selectable in 1/2 dB steps. Voice encoding is Mu-law and input impedance
is 900 ohms + 2.16uF. BC-Tel special design. |
REQUEST QUOTE |
| 90-0348-01 |
19 inch rack mountable assembly which provides backplane access
to eight X.21 circuits via DB-15 connectors. Included are two 25 pair cables
required to connect the distribution panel to the system. |
REQUEST QUOTE |
| 90-0348-03 |
Mainstreet X.21 Distribution panel comes complete with shielded
AMP Champ cable, for installation in other environments including Telecom
Centres. |
REQUEST QUOTE |
| 90-0349-01 |
19 inch rack mountable assembly which provides backplane access
to six V.35 circuits via six DB-25 connectors. Included are two 25 pair
cables required to connect the distribution panel to the system. |
REQUEST QUOTE |
| 90-0349-04 |
V.35 Distribution panel comes complete with shielded AMP Champ
cable and DB25 connectors, for installation in other environments including
Telecom Centres. |
REQUEST QUOTE |
| 90-0350-01 |
19 inch rack mountable assembly which provides backplane access
to six RS-232 circuits via six DB-25 connectors. Included are two 25 pair
cables required to connect the distribution panel to the system. |
REQUEST QUOTE |
| 90-0350-04 |
Mainstreet RS232 Distribution panel comes complete with shielded
AMP Champ cable, for installation in other environments including Telecom
Centres. |
REQUEST QUOTE |
| 90-0369-01 |
Daughter card for the single T1 interface card (90-0093-05) or
the single E1 interface card (90-0371-02). Provides for A law to Mu law
conversion. |
REQUEST QUOTE |
| 90-0371-02 |
Mother card for single 2.048 Mbps E1 electrical interfaces.
Conforms to CCITT G.703 and G.732. Requires the E1 LIM (90-0568-01) daughter
card to complete the interface. The Superrate Adaptor Module (90-0469-01) for
E1/T1 rate conversion or the Companding Conversion Module (90-0369-01) for
A-law, Mu-law conversion are also supported. |
REQUEST QUOTE |
| 90-0371-06 |
Similar to 90-0371-02 but tailored for 120 OHM application.
Supports rear AMP CHAMP signal access only. Requires one 90-0568-02 (120 ohm)
E1 LIM. |
REQUEST QUOTE |
| 90-0411-57 |
Desktop, wall-mount, 19
rack-mount system. Does not require 36SM SHELF ASSY (90-1313-02). Provides
two E-1(2.048 Mb/s) links. Includes internal power supply (100-240VAC) with
integral ringing generator (factory set to 25Hz, user configurable to 20Hz),
common control, Universal card, display assembly and software 91X5. Optional
slide assembly (90-9084-01), optional wall mount bracket (90-0338-04), and
customer documentation (90-0433-03) to be ordered separately. |
REQUEST QUOTE |
| 90-0411-58 |
Desktop, wallmountable, 19 rackmountable system. Does not
require 36SM SHELF ASSY (90-1313-02). Provides two E-1 (2.048 Mb/s) links.
Includes internal 48VDC power supply with integral 25Hz ringing generator,
common control, Universal card, display assembly and software 91X5. Optional
slide drawer (90-9084-01), optional wall mount bracket (90-0338-04), and
customer documentation (90-0433-03) to be ordered separately |
REQUEST QUOTE |
| 90-0411-67 |
This is the 3630 19 rack-mount system complete with sliders
attached for easy installation. Does not require 36SM SHELF ASSY
(90-1313-02). Provides two E-1(2.048 Mb/s) links. Includes internal power
supply(100-240VAC) with integral ringing generator (factory set to 25Hz, user
configurable to 20Hz), common control,Universal card, display assembly and
software 91X5. |
REQUEST QUOTE |
| 90-0411-68 |
This is the 3630 19 rack-mount system complete with sliders
attached for easy installation. Does not require 36SM SHELF ASSY
(90-1313-02). Provides two E-1 (2.048 Mb/s) links. Includes internal 48VDC
power supply with integral 25Hz ringing generator, common control, Universal
card, display assembly and software 91X5. |
REQUEST QUOTE |
| 90-0412-52 |
Desktop, wall-mount, 19
rack-mount system. Does not require 36SM SHELF ASSY (90-1313-02). Provides
two T-1(1.544 Mb/s) links. Includes internal power supply (100-240VAC) with
integral ringing generator (factory configured to 20Hz, user configurable to
25Hz), common control, Universal card, display assembly and software 91X5.
Optional slide assembly (90-9084-01), optional wall mount bracket
(90-0338-04), and customer documentation (90-0433-03) to be ordered separately. |
REQUEST QUOTE |
| 90-0412-58 |
Desktop, wallmountable, 19 rackmountable system. Does not
require 36SM SHELF ASSY (90-1313-02). Provides two T-1 (1.544 Mb/s) links.
Includes internal 48VDC power supply with integral 20Hz ringing generator
20Hz, common control, Universal card, display assembly and software 91X5.
Optional slide drawer (90-9084-01), optional wall mount bracket
(90-0338-04),and customer documentation (90-0433-03) to be ordered separately |
REQUEST QUOTE |
| 90-0412-62 |
This is the 3630 19 rack-mount system complete with sliders
attached for easy installation.Does not require 36SM SHELF ASSY (90-1313-02).
Provides two T-1(1.544 Mb/s) links. Includes internal power
supply(100-240VAC) with integral ringing generator (factory configured to
20Hz,user configurable to 25Hz), common control, Universal card, display
assembly and software 91X5. |
REQUEST QUOTE |
| 90-0412-68 |
This is the 3630 19 rack-mount system complete with sliders
attached for easy installation. Does not require 36SM SHELF ASSY
(90-1313-02). Provides two T-1 (1.544 Mb/s) links. Includes internal 48VDC
power supply with integral 20Hz ringing generator 20Hz, common control,
Universal card,display assembly and software 91X5. |
REQUEST QUOTE |
| 90-0425-01 |
Single FXS (LGS) module for general applications interfacing to
voice terminal equipment certified to connect to public networks in the
United Kingdom; module provides line reversal and third-wire capability; does
not apply to 3624 MainStreet. Offers TLP's of +1/-6 for receive and +4/-3 for
transmit. |
REQUEST QUOTE |
| 90-0432-01 |
Supports both DTE and DCE operation. Supports both HCM and
Transparent rate adaption. Two control leads supported: C/I. Supports NX56/64
super-rate operation. ***This module cannot be used as a source for system
synchronization.*** |
REQUEST QUOTE |
| 90-0433-03 |
A set of manuals for the 3630 at Release 5. Includes
Installation, Configuration, Maintenance manuals as well as a Quick Reference
Guide. Manuals are assembled in a binder. |
REQUEST QUOTE |
| 90-0433-04 |
A set of manuals for the 3630 at Release 5.3. Includes
Installation, Configuration, Maintenance manuals as well as a Quick Reference
Guide. Manuals are assembled in a binder. |
REQUEST QUOTE |
| 90-0466-01 |
One per 3612 or 3630 required, if 48V signalling is required
with LGS interfaces, or Vbat feed for E<(>&<)>M type 2
interfaces. |
REQUEST QUOTE |
| 90-0470-04 |
This circuit card consists of 4 circuits which comply to the
CCITT G.703 standard at a bit rate of 64 kb/s. E1 signalling is also
supported by this card as well as the AIS capability by Generic 1115 or
greater. |
REQUEST QUOTE |
| 90-0512-01 |
One per system required for Megacom800 and PLAR applications,
where the CPE does not send ringback tone to the network; module is mutually
exclusive with DDS Module (90-0160-01 or 90-0160-02) or any of the DSP
modules. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-0523-01 |
Single V.35 module providing for a single V.35 compatible
interface (DTE or DCE) per module. Three control leads are supported;
DCD/RTS/ALB when configured as DCE. These modules cannot be used to derive a
clock for system synchronization. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0526-01 |
Single FXO (LGE) module for end-to-end or corporate network
connections interfacing to North American voice terminal equipment with TLP's
for receive and transmit of 0 to -7 DB; module operates as FXO or DPT
circuits. |
REQUEST QUOTE |
| 90-0526-02 |
Single FXO (LGE) module for general applications interfacing to
European and International voice terminal equipment with TLP's for receive
and transmit of 0 to -7 DB. |
REQUEST QUOTE |
| 90-0526-03 |
Single FXO (LGE) module for termination of North American public
network services such as UltraWATS, SDN, Megacom and VPN series offering
TLP's of -3 to -10 DB for receive and +3 to -4 DB for transmit; module
operates as FXO or DPT circuits. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0530-11 |
Contains DB25 to RJ45 cable adaptors, RJ45 cables, anti-static
strap, miscellaneous tools and mounting hardware required to install one
2902, 3612, 3620, 3624, or 3630 wall mount system. |
REQUEST QUOTE |
| 90-0555-16 |
Straight through male to female ampchamp cable with 180 deg.
headshell. |
REQUEST QUOTE |
| 90-0562-07 |
System software for 3630 T1 and E1 systems. Includes a frotn
panel label (new alarm LED designators) required when upgrading from Release
2, 3, 4, or existing release 5. |
REQUEST QUOTE |
| 90-0564-01 |
This card provides two 1.544 Mbps T1 digital trunk interfaces.
Used to compress 44 voice channels to a single T1 link when equipped with the
Voice Compression Module (90-0566-01). Requires one T1 LIM (90-0567-01) for
each T1 interface connection to a T1 channel service unit. Also supports one
CSU-2 Module (90-0161-02) for each T1 interface connection directly to a
carrier's T-1 lines when using Generic 1115 or greater. Supports one Timeslot
24 Signalling Module (90-1668-01) to provide a dedicated timeslot for passing
signalling when using Generic 1115 or greater. This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0566-04 |
Daughter card used on the Dual T1 (90-0564-01) and Dual E1
(90-9244-01, 90-9244-02) mother cards to provide up to 44 ANSI compatible or
55 CCITT compatible ADPCM compressed voice channels using bundled (delta
channel) signalling. When using 3600/45 Release 5.2 or greater, transitional
signalling is also available. |
REQUEST QUOTE |
| 90-0567-01 |
One per T-1 circuit required for operation with external CSU or
for systems requiring a DSX-1 electrical interface; provides enhanced
loop-back capabilities and circuitry for bypass switching and interface
redundancy. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0567-01 |
One per T-1 circuit required for operation with external CSU or
for systems requiring a DSX-1 electrical interface; provides enhanced
loop-back capabilities and circuitry for bypass switching and interface
redundancy. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0568-01 |
One per E-1 circuit required to interface to G.703 75 ohm
asymmetrical; includes enhanced loop-back capabilities and circuitry for
bypass switching and interface redundancy. This assembly contains a Telcordia
CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0568-01 |
One per E-1 circuit required to interface to G.703 75 ohm
asymmetrical; includes enhanced loop-back capabilities and circuitry for
bypass switching and interface redundancy. This assembly contains a Telcordia
CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0568-02 |
Variant of the E1 LIM (90-0568-01) which only supports 120 ohm
interface. All other features of the E1 LIM are supported. |
REQUEST QUOTE |
| 90-0568-02 |
Variant of the E1 LIM (90-0568-01) which only supports 120 ohm
interface. All other features of the E1 LIM are supported. |
REQUEST QUOTE |
| 90-0569-03 |
This card presents a 30 channel, X.21/V.11 interface. Allows for
faceplate (DB-15) or backplane (50 pin Champ) access. Configured as a Data
Termination Unit (DTE). Supported bit rates are from 64 Kbps to 1920 Kbps.
Also supported by this card in generic 1113 or greater is reduced framing
overhead allowing for additional HCM data. |
REQUEST QUOTE |
| 90-0569-06 |
This card is similar to 90-0569-03 but is modified to support
Krypto Gear-81 crypto units (encryption NTUs). Supported by Generic 1116 or
greater. |
REQUEST QUOTE |
| 90-0571-01 |
Adaptor plate required to mount 90-0348-01, 90-0349-01,
90-1066-01 and 90-0350-01 distribution panels in 23 inch equipment racks.
Only one required. |
REQUEST QUOTE |
| 90-0571-02 |
Adaptor plate required to mount 90-0010-02, 90-0010-04, and
90-0010-10 3600 shelves to 23 equipment racks. Only one required. |
REQUEST QUOTE |
| 90-0571-03 |
Adaptor plate required to mount the 90-0890-01, 90-0890-02, and
90-1236-01 assemblies or any other 19 inch rack mount assemblies of two
vertical units, to a 23 inch rack. |
REQUEST QUOTE |
| 90-0571-04 |
Adapter plate required to mount 90-1637-01 FASTBUS Interconnect
Panels in 23 equipment rack. Only one required. |
REQUEST QUOTE |
| 90-0571-05 |
Adaptor plate required to mount one 3600/3600+ Ext R/G Assy
(90-5945-01) into a 23 equipment rack. Only one required per ringer assembly. |
REQUEST QUOTE |
| 90-0611-01 |
Single RS232 module providing for dual RS-232/V.24 interfaces
per module. Most common synchronous and asynchronous speeds are supported up
to 64KBPS. Both HCM and transparent framing formats are supported. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-0616-01 |
The Digital Processor Module-2 is a daughter card to the 27LC2
mother card (90-1184-05). Provides DDS or X.50 sub rate multiplexing
functinality. One DPM2 module per 27LC2 card. This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0627-01 |
Single manual ringdown module for end-to-end network connections
interfacing to North American voice terminal equipment with TLP's for receive
and transmit of 0 to -15DB; module operates as end station interface using
manually controlled ringing. |
REQUEST QUOTE |
| 90-0627-10 |
Manual Ringdown A-LAW Module with 600 Ohm resistive impedance.
Tailored for Gen/Gen use only. |
REQUEST QUOTE |
| 90-0628-04 |
Identical to 90-0628-02 except the cable is 6 meteres in length. |
REQUEST QUOTE |
| 90-0639-03 |
This card is required in each 3600 Peripheral Shelf pair (1 or 2
depending on Peripheral redundancy). For upgrade of a 3600 to a 3600
Peripheral Shelf, each 3600 Expander card is replaced by a Switching
Interface Card. This assembly is similar to 90-0639-01 but allows for rear
panel connectivity. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0640-03 |
This card is a full replacement for the Switching Card
(90-0640-01). It must be used with 3600 Switching Shelf Generic C111-07-00 or
greater. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-0641-01 |
This card is used in the 3600 Switching Shelf to provide the
system clocking (Stratum-3) for the 3600 Multi Shelf System. One Clock Card
is required per 3600 Switching Shelf. |
REQUEST QUOTE |
| 90-0641-04 |
Identical to 90-0641-01 but provides enhanced alarm I/O
capabilities (AM-2). This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0652-02 |
This shelf consists of a card cage and backplane and
accommodates up to eight E-3 Cards (90-1224-01/02) and eight Fibre Interface
Cards (90-1616-01). Uses up to two 90-0899-04 DC power supplies. Inc ludes
EMC front cover. Meets EMC class B requirements when EMC front cover is
installed correctly. |
REQUEST QUOTE |
| 90-0654-01 |
This cable assembly is required to link the 3600 Switching
Shelves (90-0662-01/03) to the 3600 Peripheral Shelves. For each Switching
Shelf, one cable assembly is required for each Switching Interface card in
the system. |
REQUEST QUOTE |
| 90-0654-04 |
Same as 90-0654-01 but with a total length of 18 feet. |
REQUEST QUOTE |
| 90-0654-06 |
Same as 90-0654-01 but with a total length of 25 feet. |
REQUEST QUOTE |
| 90-0654-09 |
Same as 90-0654-08 but with a total length of 18 feet. |
REQUEST QUOTE |
| 90-0654-10 |
Same as 90-0654-08 but with a total length of 25 feet. |
REQUEST QUOTE |
| 90-0654-12 |
This cable assembly is required to link the 3600 Switching
Shelves (90-0662-01/03) using PMX Switching Card (90-0640-03) only to
Peripheral Shelves (90-0010-05/09/10) equipped with PMX Switching Interface
Card (90-0639-03), front panel connection. |
REQUEST QUOTE |
| 90-0661-01 |
This module is required on the Switching Card (PMX)
(90-0640-03). It provides additional circuitry for 64MB/s throughput. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-0662-03 |
This is a 19 inch shelf assembly for use with either an AC or DC
power shelf. This assembly allows for dual DC power input applications when
used with the 90-0664-01/02 DC Power Shelves. This shelf is required for each
3600 Multi Shelf System and accomodates up to eight Switching Cards
(90-0640-XX). Two shelves are required if the 3600 Multi Shelf System is
configured for redundant switching operation. Consists of a cardfile and
backplane. (Previously called Switching Shelf Dual DC I/P). |
REQUEST QUOTE |
| 90-0662-04 |
This shelf is required for each 3600 Multi Shelf System and
accomodates up to eight Switching Cards (90-0640-XX). Two shelves are
required if the 3600 Multi Shelf System is configured for redundant switching
operation. Consists of a cardfile and backplane. To be used only with the DC
Power supply and tray (-48/60V)(90-9524-02/90-3669-03). Meets Class B EMC and
Bellcore TR-1089 requirements when configured appropriately. |
REQUEST QUOTE |
| 90-0662-05 |
This shelf is required for each 3600 Multi Shelf System and
accomodates up to eight Switching Cards (90-0640-XX). Two shelves are
required if the 3600 Multi Shelf System is configured for redundant switching
operation. Consists of a cardfile and backplane. To be used only with the AC
Power supply and tray (120V) (90-9524-01/90-3669-01/90-3669-02) or the AC
Power supply and tray (240V) (90-9524-01/90-3669-01/90-3669-05). Meets Class
B EMC and Bellcore TR-1089 requirements when configured appropriately. |
REQUEST QUOTE |
| 90-0667-01 |
This card is required for each 3600 shelf (90-0010-10,
90-0010-13, and 90-0010-14). The card supports releases 7.1, and 8.0. The
downloadable memory module is not included but required for proper operation.
This card also requires an expander card (90-0035-05) in most applications
requiring double bandwidth. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0667-05 |
This card is required for each 3600 shelf (90-0010-10,
90-0010-13, and 90-0010-14). The card supports releases 7.1, and 8.0. The
downloadable memory module is not included but required for proper operation.
This card has an integral exapander module and can operate in single shelf
double bandwidth for 8 slots. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0668-01 |
This cabinet is for customer premises applications and houses up
to three Switching, Peripheral and High Speed Peripheral shelves. Three
shelves are accommodated from the front. The side panels are rem ovable and a
glass front door is included. |
REQUEST QUOTE |
| 90-0669-01 |
This card presents a 30 channel, V.35 interface. Allows for
faceplate (DB-25) or backplane (50 pin Champ) access. Configured as a Data
Termination Unit (DTE). Supported bit rates are from 64 Kbps to 1920 Kbps.
This card is supported by Generic 1113 or greater, and also offers reduced
framing overhead allowing for additional HCM data. For use with V.35
DB25M-M34M DCE Cables (90-0360-0X). |
REQUEST QUOTE |
| 90-0669-03 |
This card presents a 56 kbps V.35 interface. Supported by
Generic 1114 or above. Based on the (90-0669-01) V.35 PRI Card platform. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-0670-01 |
The Data Communication Processor card provides for increased
CPSS throughput. This card is supported by Generic 1113 or greater. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-0697-01 |
This cable assembly is required when configuring redundant
Switching Shelves. Included is one cable assembly (4 ft). |
REQUEST QUOTE |
| 90-0697-03 |
Identical to 90-0697-01-01 but tailored for EMC Class B
applications. |
REQUEST QUOTE |
| 90-0890-01 |
This assembly consists of a 19 inch rackmount fan tray equipped
with two fans. Power for this assembly is provided by the 90-0010-04/10
Single Shelves. The assembly requires 2 units ( 3 1/2 inches) of vertical
space in a 19 inch rack. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0890-02 |
This assembly consists of a 19 inch rackmount fan tray equipped
with three fans. Power for this assembly is provided by the 90-0662-01/03
Switching Shelves. |
REQUEST QUOTE |
| 90-0890-03 |
This assembly consists of a 19 inch rackmount fan tray equipped
with three fans. Power for the assembly is provided by the 90-0662-04/05 EMC
Switching Shelves or 90-0010-13/14 EMC Peripheral Shelves. The assembly
requires 2 units (3 1/2 inches) of vertical space in a 19 inch rack. |
REQUEST QUOTE |
| 90-0890-05 |
Similar to 90-0890-03, but tailored for Siemens. |
REQUEST QUOTE |
| 90-0899-03 |
For use in 23 inch DC 8UCS (90-0010-15) or 23 inch DC Switching
Shelf (90-0662-06). This power supply is also used in the 3600+ 19 shelf
(90-2671-02) and 23 shelf (90-2672-02). Two power supplies can be installed
in the 90-0010-15 or 90-0662-06 for redundancy or load sharing. In a 3600+
shelf, power supply redundancy is met in a 2+1 configuration. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-0899-04 |
DC plug-in power supply for High Speed Peripheral Shelf-2
(90-0652-02). Two power supplies can be installed for redundancy or load
sharing. |
REQUEST QUOTE |
| 90-1043-01 |
G.703 Co-directional DCM's. Two interfaces provided without
signalling, one interface with ABCD signalling (software selectable). Either
interface can provide system sync. |
REQUEST QUOTE |
| 90-1066-01 |
19 inch rack mountable assembly which provides backplane access
to six V.35 circuits via six M34 female connectors. Included are two 25 pair
cables required to connect the distribution panel to the system. |
REQUEST QUOTE |
| 90-1066-04 |
Mainstreet V.35 Distribution panel comes complete with shielded
AMP Champ cable and M34 connectorsm, for installation in other environments
including Telecom Centres. |
REQUEST QUOTE |
| 90-1184-05 |
This card provides six 2B1Q interfaces to 270X Extended Range
Data Termination Units (DTU's). Data Format for each circuit is 2B+D, with an
effective throughput of 144KBPS. This card is for use in 360 0/3645 systems,
and is the mother card for the DPM1 (90-0297-02) and DPM2 (90-0616-01). |
REQUEST QUOTE |
| 90-1224-11 |
This card supports one E-3 (34Mb/s) interface. It is located in
the High Speed Periheral Shelf-2 (90-0652-02). It may be configured in
non-redundant and redundant configurations (ie. with another card). Provides
electrical (metallic) E-3 interface or an optional fibre optic interface
using the Fibre Interface Card-2 (90-2866-01). Requires a 3600 Switching
Shelf Generic C117.1 equipped with a High Speed Peripheral Shelf-2
(90-0652-02). |
REQUEST QUOTE |
| 90-1224-12 |
This card supports two E-3 (34Mb/s) interfaces. It is located in
the High Speed Periheral Shelf-2 (90-0652-02). It may be configured in
non-redundant and redundant configurations (ie. with another card). Provides
electrical (metallic) E-3 interfaces. Requires a 3600 Switching Shelf Generic
C117.1 equipped with a High Speed Peripheral Shelf-2 (90-0652-02). |
REQUEST QUOTE |
| 90-1224-13 |
This card supports one E-3 (34Mb/s) interface. It is located in
the High Speed Periheral Shelf-2 (90-0652-02). It may be configured in
non-redundant and redundant configurations (ie. with another card). Provides
electrical (metallic) E-3 interface or an optional fibre optic interface
using the Fibre Interface Card-2 (90-2866-01). Requires a 3600 Switching
Shelf Generic C118.0 equipped with a High Speed Peripheral Shelf-2
(90-0652-02). |
REQUEST QUOTE |
| 90-1224-14 |
This card supports two E-3 (34Mb/s) interfaces. It is located in
the High Speed Periheral Shelf-2 (90-0652-02). It may be configured in
non-redundant and redundant configurations (ie. with another card). Provides
electrical (metallic) E-3 interfaces. Requires a 3600 Switching Shelf Generic
C118.0 equipped with a High Speed Peripheral Shelf-2 (90-0652-02). |
REQUEST QUOTE |
| 90-1228-02 |
The LGS Channel Unit provides an interface of 600 or 900 ohms to
the 3600/45 system and the station end of 2-wire special service circuits.
Provides FXS, DPO and GT functionality. Attenuation range in 0.1 dB steps. TX
TLP levels of 0 to -12 dB and RX TLP levels of +6 to -10 d_B. Requires 3600
equipped with common carrier card (90-1234-01). This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-1229-02 |
The LGE Channel Unit provides an interface to the 3600/45 system
and the Central Office end of 2-wire special service circuits. Provides FXS,
DPO and GT functionality. Attenuation range in 0.1 dB steps. TX TLP levels of
0 to -12 dB and RX TLP levels of +6 to -10 dB. Requires 3600 equipped
with common carrier card (90-1234-01). Identical to 90-1229-01 but tailored
for Canadian Telco applications. |
REQUEST QUOTE |
| 90-1230-02 |
The E<(>&<)> M, 2/4W Channel Unit provides an
interface of 600 ohms or 900 ohms to the 3600/3645 system and 2 and 4-wire
E<(>&<)>M special service circuits. Operates as Type I, II
and III signalling and Pulse Link Repeater (PLR). Attenuation range in 0.1dB
steps. 4W Tx/Rx levels +7 to -16dBm, 2W Tx TLP levels of 0 to -12dB and Rx
TLP levels of +6 to -10 dB. Requires 3600 equipped with Common Carrier Card
(90-1234-01). Similar to 90-1230-01 but features revised. Tip and ring
pinouts (while operating in 2-wire mode) and revised signalling pair access
through the Test Card (90-1235-01-xx). |
REQUEST QUOTE |
| 90-1231-02 |
The OCU-DP Channel Unit provides an interface to the 3600/3645
system and 4 wire special service data circuits. DDSI/II compatible. Error
correction and secondary channel. Data rates of 2.4, 4.8, 9.6, 19.2 and 56
kb/s. Min 40dB insertion loss. Requires 3600 equipped with Common Carrier
card (90-1234-01). This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-1231-03 |
This product is used with the 3600 and 3600+ Mainstreet. The
OCU-DP channel unit provides a special service data circuit for the 3600
Mainstreet. DDS I and II compatible. Error correction and secondary channel.
Data rates of 2.4, 4.8, 9.6, 19.2, and 56kbs. |
REQUEST QUOTE |
| 90-1232-01 |
The 2B1Q Channel Unit provides an interface to the 3600/3645
system and 2 wire ISDN subscriber circuits. Line code is North American
Standard 2B1Q. Line format is 2B+D, range is 5km. Requires 3600 equipped with
Common Carrier Card (90-1234-01). Supported by Generic 1116 or greater. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-1233-01 |
The DS0-DP Channel Unit provides an interface to the 3600/3645
system and central office DSX-0 signals. DDS I/II compatible. Error
correction and secondary channel. Data rates of 2.4, 4.8, 9.6, 19.2 and 56
and 64 Kb/s. Requires 3600 equipped with Common Carrier Card (90-1234-01).
Supported by Generic 1116.1 or greater. This assembly contains a Telcordia
CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-1234-01 |
The Common Carrier card allows up to four channel units to
interface to a 3600. Plugs into any UCS. Provides metallic test access relays
for customer loop testing. A front cover (90-3647-01) is required when this
card is used in Class B or EU application. This assembly contains a Telcordia
CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-1235-01 |
The Test Card provides metallic test access (Monitor
<(>&<)> Split) to the customer loop on 3600 channel units.
Test ac cess jacks are provided for the metallic test bus. Contains a DS0
interface for OCU-DP testing, with test access jacks and 5 pin connectors
clock for Tx/Rx. Plugs into any UCS. |
REQUEST QUOTE |
| 90-1236-01 |
This assembly is used to deflect a hot air source away from an
assembled 3600 or 3645 shelf (90-0010-05/10, 90-0662-03). The assembly
requires 2 units ( 3 1/2 inches) of vertical space in a 19 inch rack. The 23
Adaptor (90-0571-03) is required for 23 inch rackmounting. |
REQUEST QUOTE |
| 90-1236-03 |
This assembly is used to deflect a hot air source away from an
assembled 3600 or 3645 23 inch shelf (90-0010-15, 90-0662-06). The assembly
requires 1 unit (1 3/4 inches) of vertical space in a 23 inch rack. |
REQUEST QUOTE |
| 90-1319-01 |
This daughter module provides six individual circuits which
allow Group 3 FAX demodulation or HCV compression from an analog interface to
an aggregate interface when used with the 90-0038-11/15 DSP-4 m othercard. |
REQUEST QUOTE |
| 90-1374-01 |
This module is used to fill in module slot positions whose
bandwidth is used for superrate operations, to prevent other modules from
being plugged in. Package of 3. |
REQUEST QUOTE |
| 90-1452-01 |
The 4WTO Channel Unit provides an interface of 600 ohms to the
3600 and 4-wire Transmission only (TO) circuits. Tx TLP levels +13 to -17dB
and Rx TLP levels of +8 to -16dB. Attenuation range is 0.1dB steps. Requires
3600 equipped with Common Carrier card (90-1234-01). Sealing current 6mA min. |
REQUEST QUOTE |
| 90-1458-01 |
This package includes six channel unit filler plates. These are
used to protect unused channel unit positions on a 3600 common carrier card
(90-1234-01). |
REQUEST QUOTE |
| 90-1549-01 |
This assembly consists of four RS-422/CCITT V.11 interfaces,
each independently programmable for V.35, X.21, V.36, RS-449 or RS-530.
Individual circuit clocking for data rates of 1200 b/s to 1920 kb/s is
provided by this assembly. This part is supported by Generic 1115 or greater. |
REQUEST QUOTE |
| 90-1579-01 |
Module required to support X.21 <(>&<)> V.35 DCM
speeds above 64 kb/s (n * 64K). For E1 3630's this module is required to
support one or more super-rate ports. For T1 3630's the module is only
required where more than one super-rate port is needed. This module is
mutually exclusive with any other 36SMCP module (including Tone, DSP and VCB
modules). For both E1 and T1 systems this module is required for 4602/46020
GUI support. |
REQUEST QUOTE |
| 90-1583-01 |
This cable is required to interconnect the 90-0662-01/03
Switching Shelf interface cards to the 90-0652-02 High Speed Peripheral
Shelf-2 interface cards. (Previously called DIN to DB37M 10FT) |
REQUEST QUOTE |
| 90-1583-02 |
Identical to 90-1583-01 but 18 ft in length. (Previously called
DIN to DB37M 18FT). |
REQUEST QUOTE |
| 90-1583-03 |
Identical to 90-1583-01 but 25ft in length. (Previously called
DIN to DB37M 25FT). |
REQUEST QUOTE |
| 90-1584-04 |
This cable assembly has two applications. 1. This cable assembly
is required to link the 3600 EMC Switching Shelves (90-0662-04/05) equipped
with EMC PMX Switching Card (90-0640-04) to EMC Peripheral Shelves
(90-0010-13/14) equipped with EMC PMX Switching Interface Cards (90-0639-05),
rear panel connection. 2. This cable assembly is required to link the 3600
Switching Shelves (90-0662-04/05) equipped with EMC PMX Switching Card
(90-0640-04) to High Speed Peripheral Shelf-2 (90-0652-02) equipped with E-3/Dual
E-3 Interface Card (90-1224-01,90-1224-02), rear panel connection. MD
Effectivity Date=March-01-2000 as per PDN#1288A. |
REQUEST QUOTE |
| 90-1585-01 |
Digital voice conference bridge module with a maximum capacity
of eight bridges. The eight bridges are partitioned into two groups of four,
each group has a pool of 12 inputs which can be allocated as desired across
the four bridges. This module is installed in the DSP slot of the 3630 and is
mutually exclusive with Tone or DDS modules (90-0512-01, 90-0160-01). |
REQUEST QUOTE |
| 90-1610-02 |
Identical to 90-1610-01, but tailored for Class A Operation.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-1615-01 |
19 inch rack mountable assembly which provides backplane access
to four circuits from the RS-422 DCC (90-1549-01) via four adaptor modules
(90-1642-01/02/03/04/05/06/07/08). Each module position can be independently
provisioned with a different interface module to correspond to the type of
interface each RS-422 DCC port has been configured as (ie. RS-530,
RS-449/V.36, X.21 or V.35). Included are two 25 pair cables required to
connect the distribution panel to the system. |
REQUEST QUOTE |
| 90-1615-02 |
This assembly which is tailored for EMC Class B applications is
a 19 inch rack mountable assembly which provides backplane access to four
circuits from the RS-422 DCC (90-1549-01) via four adaptor modules
(90-1642-01/02/03/05/06/07/08). Each module position can be independently
provisioned with a different interface module to correspond to the type of
interface each RS-422 DCC port has been c onfigured as (ie. RS-530,
RS-449/V.36, X.21 or V.35). Included are two 25 pair cables required to
connect the distribution panel to the system. |
REQUEST QUOTE |
| 90-1637-01 |
Panel that terminates up to 12 STP modules (90-1832-01) and
optionally, 2 cascade modules; either STP (90-1651-01) or fibre (90-1653-01).
Unused positions must be stuffed with bypass modules (90-1652-01). Includes
backplane, card file, 2 STP modules (90-1832-01) and 13 bypass modules
(90-1652-01) |
REQUEST QUOTE |
| 90-1638-28 |
FRE R4.3 FRE card with Release 4.3 frame relay software, which
includes the DLCI multiplexing features. This card requires software generic
P414-XX-XX. For software upgrades, order 90-7609-03 FRE S/W DNLOAD KEY
P414-H3. |
REQUEST QUOTE |
| 90-1642-01 |
RS530 Interface adaptor configured as a DTE port for use with
the 90-1615-01 Universal Distribution Panel. |
REQUEST QUOTE |
| 90-1642-02 |
RS530 Interface adaptor configured as a DCE port for use with
the 90-1615-01 Universal Distribution Panel. |
REQUEST QUOTE |
| 90-1642-03 |
Single Port DB37 RS449/V.36 DTE Adaptor Module for use with
Universal Distribution Panel (90-1615-01). |
REQUEST QUOTE |
| 90-1642-04 |
Single Port DB37, RS449/V.36 DCE Adaptor Module for use with
Universal Distribution Panel (90-1615-01). |
REQUEST QUOTE |
| 90-1642-05 |
Single Port M34, V.35 DTE Adaptor Module for use with Universal
Distribution Panel (90-1615-01). |
REQUEST QUOTE |
| 90-1642-06 |
Single Port M34 V.35 DCE Adaptor Module for use with Universal
Distribution Panel (90-1615-01). |
REQUEST QUOTE |
| 90-1642-07 |
Single Port DB15, X.21 DTE Adaptor Module for use with Universal
Distribution Panel (90-1615-01). |
REQUEST QUOTE |
| 90-1642-08 |
Single Port DB15, X.21 DCE Adaptor Module for use with Universal
Distribution Panel (90-1615-01). |
REQUEST QUOTE |
| 90-1644-01 |
Optional module for use with RS422 DCC (4CCT) P/N 90-1549-01.
Provides programmable slip buffers operating on a per port basis. |
REQUEST QUOTE |
| 90-1645-04 |
This Kit upgrades FRS Dual 1Mb Flash Cards (90-1459-04) and FRS
Dual 1Mb Flash Cards (EMC) (90-1459-03) to support the latest Release 4.0
functionality for HDLC & X.25 encapsulation and frame relay services.
Minimum flash memory requirements for the FRS card to support this upgrade
kit is 1 MEG. Includes 3.5 diskette. |
REQUEST QUOTE |
| 90-1651-01 |
Cascade Module for FASTBUS Interconnect Panel (90-1637-01).
Provides STP interface. This package includes two modules. |
REQUEST QUOTE |
| 90-1652-01 |
Bypass Module for FASTBUS Interconnect Panel (90-1637-01). This
package includes a single module. |
REQUEST QUOTE |
| 90-1653-01 |
Cascade module for FASTBUS Interconnect Panel (90-1637-01).
Provides fibre optic interface. This package includes two modules. |
REQUEST QUOTE |
| 90-1654-01 |
This cable is required to connect Frame Relay Engine
(90-1638-xx) and Packet Engine cards (90-2311-xx) to the FASTbus Interconnect
Panel (90-1637-01). One cable is required per FRE/PE card. Total length of 3
meters. |
REQUEST QUOTE |
| 90-1654-02 |
Identical to 90-1654-01 but with a total length of 10 meters. |
REQUEST QUOTE |
| 90-1654-04 |
Identical to 90-1654-01 but with a total length of 1.5 meters. |
REQUEST QUOTE |
| 90-1654-05 |
Identical to 90-1654-01 but with a total length of 2.5 meters. |
REQUEST QUOTE |
| 90-1655-01 |
This cable is required to connect two FASTBUS Interconnect
Panels (90-1637-01) over STP. To be used with STP cascade modules
(90-1651-01). |
REQUEST QUOTE |
| 90-1655-02 |
Identical to 90-1655-01 but with a total length of 10 meters. |
REQUEST QUOTE |
| 90-1667-01 |
Wire wrap adaptor modules. Allows for wire wrap connections to
3600/3645 systems. Package contains one set of adaptor modules for one 3600
or 3645 shelf (PU or SU). Includes two T1 (AMP CHAMP), two ALARM I/O (DB25)
and two composite clock (DB25) adaptor modules. For 90-0010-13/14/15, and
90-0662-04/05/06. Alarm I/O adapters are compatible with GFC-2 equipped with
Alarm Module-2 (90-0077-05, 90-0078-06) and Clock card equipped with Alarm
Module-2 (90-0641-03/04). |
REQUEST QUOTE |
| 90-1673-08 |
This kit upgrades existing Frame Relay Engine Cards to Release
4.3 functionality. Includes 3.5 diskettes. |
REQUEST QUOTE |
| 90-1831-01 |
Wire wrap adaptor modules. Allows for wire wrap connections to
3600/45 systems. Package contains 16 T1 AMP CHAMP modules. |
REQUEST QUOTE |
| 90-1832-01 |
STP Module installed in the FASTbus Interconnect Panel
(90-1637-01) to connect one FRE or PE card to the FASTbus. Note that each FIP
(90-1637-01) is supplied with two 90-1832-01 modules pre-installed. |
REQUEST QUOTE |
| 90-2099-01 |
The Subrate Interface (SRI) Module is added to the Frame Relay
Switch Card (90-1459-0X-XX) to enable the support of subrate speeds which are
not multiples of 8K. The module also supports X.50 BIS @ 48kbps, X.50 DIV
2,3, <(>&<)> 5, HCM and DDS. |
REQUEST QUOTE |
| 90-2180-01 |
The Termination Card is used to terminate the high speed signals
on the backplane of the Switching Shelf Cardfile. One Termination Card is
required per Switching Shelf Cardfile and is mandatory for proper operation.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-2181-01 |
The Switching Shelf Cardfile is a 19 rackmount shelf which is
composed of 8 Dual Switching Card slots, 8 Dual Receiver Card slots, and one
Termination Card slot. The minimum configuration is one Termination, one Dual
Receiver, and one Dual Switching Card. The Dual Receiver and Dual Switching
Card slots are associated and always go in pairs. The shelf is scalable from
one Dual Receiver/Switching Card to 8 Dual Receiver/Switching Cards in
increments of one. One Switching Shelf Cardfile implements a complete 36170
ATM switching matrix (12.8 Gbps): if fabric redundancy is required a second
Switching Shelf Cardfile is required. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-2183-02 |
The Dual Receiver Card can terminate the received interface of
up to two 800 Mbps ISL links. One to eight Dual Receiver Cards can be
installed in the Switching Shelf Cardfile for a total throughput of 12.8Gbps.
This card is identical to the 90-2183-01 except with 1310 Nm optics. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-2183-04 |
The Extended ISL (X-ISL) Dual Receiver Card can terminate the
receive interface of two 800 Mbps X-ISL links. One to eight Dual Reciever
Cards can be installed in the switching shelf for a total throughput of 12.8
Gps. X-ISL reach is 15km over customer supplied Single Mode Fiber. SMF cable
requirements are 9/125 micron core/cladding, 0.35 dB/Km attenuation at
1310nm, flat polish SC/SC connector. |
REQUEST QUOTE |
| 90-2197-01 |
This card provides eight Basic Rate Interfaces (BRI) interfaces
for use at either the S or T reference points. This card is supported by
Generic 1116 or greater. |
REQUEST QUOTE |
| 90-2197-02 |
This card provides four Basic Rate Interface BRI interfaces for
use at either the S or T reference points. This card is supported by Generic
1116 or greater. |
REQUEST QUOTE |
| 90-2254-01 |
Mounting bracket used for mounting two 3620 Distribution Panels
(90-2255-01) or two 3612/24 Base Distribution Panels (90-2256-01) or one 3630
Base Distribution Panel (90-2257-01) into a 19 rackmount c onfiguration.
Personality modules and Base Distribution Panels ordered separately. |
REQUEST QUOTE |
| 90-2257-03 |
Base distribution panel for use with 3630 systems. It will allow
installation of up to eight 36SM personality modules. Includes an extended
cover (90-2303-01) which allows for installation of the V.35/M34 personality
module (90-2258-04). (90-234X-XX) cables hat connect the Basic System to the
Universal Distribution Panel are sold separately. Requires 36SM Distribution
Panel rackmount bracket for rackmount installation (90-2254-01). |
REQUEST QUOTE |
| 90-2258-01 |
Dual port DB25, V.24 DCE adaptor module for use with the 36SM
Base Distribution Panel (90-2256-03 or 90-2257-03). |
REQUEST QUOTE |
| 90-2258-02 |
Single port DB15 X.21 DCE adaptor module for use with the 36SM
Base Distribution Panel (90-2256-03 or 90-2257-03). |
REQUEST QUOTE |
| 90-2258-03 |
Single port DB25, V.35
DCE adaptor module for use with the 36SM Base Distribution Panel (90-2256-03
or 90-2257-03). |
REQUEST QUOTE |
| 90-2258-04 |
Single port M34, V.35 DCE adaptor module for use with the 36SM
Base Distribution Panel (90-2256-03 or 90-2257-03). |
REQUEST QUOTE |
| 90-2258-05 |
Four port voice distribution module which provides pass through
connection from input to output AmpChamp connectors. For use with the 36SM
Base Distribution Panel (90-2256-03 or 90-2257-03). Passes termination to the
auxiliary connection for use with an external punchdown block. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-2258-09 |
Voice Direct Adaptor Module for use with the 36SM Base
Distribution Panel (90-2256-03, 90-2257-03). Used with the tributary T1, OCU,
4WTO, 2WTO, LGS, LGE, MRD and E&M Modules. |
REQUEST QUOTE |
| 90-2289-01 |
This package includes seven (7) Filler Plate Cards for the PBX
slots of the Switching Shelf. The Switching Shelf has a total of eight (8)
DRX card slots. |
REQUEST QUOTE |
| 90-2290-03 |
The Dual Fabric Interface Card (FIC) for the OC12-2 provides
interconnection of high speed interface cards installed in a High Speed
Peripheral Shelf (HSPS) to a 7470 Switching Shelf through standard 1310 Nm
Inter-shelf Links (ISLs). Each FIC terminates up to two ISLs and is used to
interface to one of the redundant switching fabrics. This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-2291-01 |
Cardfile designed for 19 rack. It is used for high speed
interface cards and Dual Fabric Interface Cards (FIC). Each High Speed
Peripheral Shelf is functionally divided into four sub-units, each comprised
of two full height interface card slots and two 1/2 height FIC slots. Each
sub-unit can support the two interface slots as either independent cards or
as a redundant pair, with redundant fabric operation in both cases. Each FIC
terminates up to two ISLs and is used to interface to one of the redundant switching
fabrics. Two FICs must be installed in each independent sub-unit of the HSPS
to provide fabric redundancy. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-2293-01 |
This package includes six (6) Filler Plate Cards for the UCS
slots of the Peripheral Shelf. The Peripheral Shelf has a total of twelve
(12) UCS Card slots. |
REQUEST QUOTE |
| 90-2295-01 |
The Control Card I/O Panel provides connectorization for both
the active and standby Control Cards. The interfaces provided are: Ethernet,
10BaseT, RS-232, and BITS clock inputs. (Wire wrap posts 1.544 meg). 1VU
brackets for mid-mounting shipped with this assembly for mid-mounting. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-2295-02 |
The Control Card I/O Panel provides connectorization for both
the active and standby Control Cards. The interfaces provided are: Ethernet
10BaseT, RS-232, and External clock inputs/outputs via BNC co nnectors
(2meg). |
REQUEST QUOTE |
| 90-2296-03 |
This part contains the Up and Down ISL cabling required to
interconnect a Dual Peripheral Shelf to the Switching Shelf, or one subunit
of a High Speed Peripheral Shelf to the Switching Shelf. This part number is
a multi-mode 3 meter duplex fiber cable with staggered ends. The part
includes two dual ISLs, where each dual ISL consists of two bundled 800 Mb/s
strands that together create an Up or Down ISL at 1.6 Gb/s. |
REQUEST QUOTE |
| 90-2296-04 |
This part contains the Up and Down ISL cabling required to
interconnect a Dual Peripheral Shelf to the Switching Shelf, or one subunit
of a High Speed Peripheral Shelf to the Switching Shelf. This part number is
a multi-mode 10 meter duplex fiber cable with staggered ends. The part
includes two dual ISLs, where each dual ISL consists of two bundled 800 Mb/s
strands that together create an Up or Down ISL at 1.6 Gb/s. |
REQUEST QUOTE |
| 90-2296-05 |
This part contains the Up and Down ISL cabling required to
interconnect a Dual Peripheral Shelf to the Switching Shelf, or one subunit
of a High Speed Peripheral Shelf to the Switching Shelf. This part number is
a multi-mode 6 meter single fiber cable with staggered ends. The part
includes two dual ISLs, where each dual ISL consists of two bundle 800 Mb/s
strands that together create an Up or Down ISL at 1.6 Gb/s. |
REQUEST QUOTE |
| 90-2297-01 |
Filler plate card for the Hub slot of the Peripheral shelf. The
Peripheral shelf has a total of 2 Hub card slots. |
REQUEST QUOTE |
| 90-2298-01 |
This package contains seven filler plates for the DSC slots in a
Switching Shelf or the High Speed Line Card slots in a High Speed Peripheral
shelf. |
REQUEST QUOTE |
| 90-2311-02 |
A 3600/3600+ UCS card
that functions as an integrated mulitprocessor, high performance frame relay
and/or X.25 switch. Supports either frame relay or X.25 protocols, or both
concurrently, depending on network and customer requirements. A total of
3.968 Mbps (2 x 1.984 Mb/s) of bandwidth is available between the card and
the switching matrix. The card supports an interface to the FASTbus via the
FIP (90-1637-01). The PE card is optimized for X.25 and supports up to 512
logical X.25 user ports per card. Minimum node software release of 6.1 is
required. Requires a fan tray to operate. Maximum three PE cards per 3600
shelf. |
REQUEST QUOTE |
| 90-2322-01 |
The Coax Adaptor provides two coaxial connectors for the OC3 and
STM1 Electrical Interface Cards. The Coax Adaptor attaches to the rear I/O
connectors of the Peripheral Shelf. |
REQUEST QUOTE |
| 90-2322-02 |
The Coax Adaptor provides six coaxial connectors for the Triple
DS3 and Triple E3 Interface Cards. The Coax Adaptor attaches to the rear I/O
connectors of the Peripheral Shelf. |
REQUEST QUOTE |
| 90-2341-01 |
Non shielded 1.5 meter in length small mux panel cable for
connecting to small mux distribution panels (90-2255/6/7-01). |
REQUEST QUOTE |
| 90-2341-02 |
Identical to 90-2341-01, but 3 meters in length. |
REQUEST QUOTE |
| 90-2341-03 |
Identical to 90-2341-01, but 6 meters in length. |
REQUEST QUOTE |
| 90-2341-04 |
Non shielded, 180 deg. headshell, 1.5 meter in length small mux
panel cable for connecting to small mux distribution panels (90-2255/6/7-03). |
REQUEST QUOTE |
| 90-2341-05 |
Non shielded, 180 deg. headshell, 3 meter in length small mux
panel cable for connecting to small mux distribution panels (90-2255/6/7-03). |
REQUEST QUOTE |
| 90-2342-01 |
Shielded 1.5 meter in length small mux panel cable for
connecting to small mux distribution panels (90-2255/6/7-01). |
REQUEST QUOTE |
| 90-2342-02 |
Identical to 90-2342-01, but 3 meters in length. |
REQUEST QUOTE |
| 90-2374-01 |
The CPC is a UCS card intended to provide support for all D
channels (BRI or PRI) terminated within a dual shelf 3600/64. It combines
with various physical interface cards to provide an ISDN-compatible
interface. It supports basic rate interfaces using the S/T BRI Card and
primary rate interfaces using the DT1-2, Dual T-1 Card and the DE1-2 Dual E-1
Card. |
REQUEST QUOTE |
| 90-2375-01 |
This assembly is a UCS resource card for inverse multiplexing
applications. Based on the Bonding standard, the application supports
n*64Kbit/s and n*56Kbit/s channels where n=15 for mode 1 and n=14 for mode 3
between 3600/45/64 nodes. Each IMC supports a total of 30
network-sidechannels (includes mode 3 monitor channels). Supoorted by Generic
1116 or greater. |
REQUEST QUOTE |
| 90-2480-91 |
7470 Release 4.3
Documentation Package. Includes Technical Info rmation Installation
Configuration and Maintenance Informati on. |
REQUEST QUOTE |
| 90-2480-92 |
7470 Release 5.0
Documentation Package. Includes Technical Info rmation Installation
Configuration and Maintenance Informati on. Manuals are assembled in a
binder. |
REQUEST QUOTE |
| 90-2480-93 |
' 7470 Release 6.0 Documentation Package. Includes Technical
Information Installation Configuration and Maintenance Informati on. Manuals
are assembled in a binder. |
REQUEST QUOTE |
| 90-2517-51 |
The 8 Port T1 Circuit Emulation Card multiplexes/ demultiplexes
the circuits carried over a TDM channelized link and performs the necessary
operations to allow the transport of these circuits through an ATM network.
This card supports both structured and unstructured service as defined by the
ATM Forum. Fits: 7470 or 7670 RSP ESE For 7670 RSP ESE, required adapter card
is 90-7272-01 This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-2517-53 |
The 8 Port E1 Circuit
Emulation Card with 75 ohm interface impedance multiplexes and demultiplexes
the circuits carried over a TDM channelized link and performs the necessary
operations to allow the transport of these circuits through an ATM network.
This card supports both structured and unstructured service as defined by the
ATM Forum. This card is not certified for use with the CE-EC echo
cancellation modules. Use the 120 ohm 8-port CE card with the CE-EC modules. |
REQUEST QUOTE |
| 90-2517-61 |
The 8 Port T1 Circuit Emulation Card multiplexes/ demultiplexes
the circuits carried over a TDM channelized link and performs the necessary
operations to allow the transport of these circuits through an ATM network.
This card supports both structured and unstructured service as defined by the
ATM Forum. Fits: 7470 or 7670 RSP ESE For 7670 RSP ESE, required adapter card
is 90-7272-01. |
REQUEST QUOTE |
| 90-2517-62 |
The 8 Port E1 Circuit Emulation Card multiplexes/demultiplexes
the circuits over a TDM channelized link and performs the necessary
operations to allow the transport of these circuits through an ATM network.
This card supports both structured and unstructured service as defined by the
ATM Forum. Fits: 7470 or 7670 RSP ESE For 7670 RSP ESE, required adapter card
is 90-7272-01 |
REQUEST QUOTE |
| 90-2517-72 |
The 8 Port E1 Circuit Emulation Card multiplexes/demultiplexes
the circuits over a TDM channelized link and performs the necessary
operations to allow the transport of these circuits through an ATM network.
This card supports both structured and unstructured service as defined by the
ATM Forum. Fits: 7470 or 7670 RSP ESE For 7670 RSP ESE, required adapter card
is 90-7272-01. |
REQUEST QUOTE |
| 90-2542-01 |
The PRI AMP/CHAMP MAU
provides a 50 pin connector for the 7470 multi-port PRI cards. It attaches to
the rear I/O connectors of the Peripheral Shelf. |
REQUEST QUOTE |
| 90-2542-02 |
The PRI Wire Wrap MAU
provides a wire wrap connector for the 74 70 multi-port PRI cards. It
attaches to the rear I/O connectors of the Peripheral Shelf. As of August 1
2003 the WW MAU will be RESTRICTED to NON EU customers only because it does
not meet Class A EU2003 for Conducted emissions on I/O Lines. The recommended
replacement part is the AMP Champ MAU: 90-2542-01 MAU,PRI AMP/CHAMP and
90-2542-04 MAU, PRI AMP/CHAMP. |
REQUEST QUOTE |
| 90-2542-03 |
The PRI Wire Wrap MAU provides a wire wrap connector (66 posts)
for the 7470 16 port PRI cards. It attaches to the rear I/O connectors of the
Peripheral Shelf (DB78). As of August 1 2003 the WW MAU will be RESTRICTED to
NON EU customers only because it does not meet Class A EU2003 for Conducted
emissions on I/O Lines. The recommended replacement part is the AMP Champ
MAU: 90-2542-01 MAU, PRI AMP/CHAMP and 90-2542-04 MAU, PRI AMP/CHAMP. |
REQUEST QUOTE |
| 90-2542-04 |
The PRI AMP/CHAMP MAU provides a 64 pin connector for the 7470
16 port PRI cards. It attaches to the rear I/O connectors of the Peripheral
Shelf (DB78). |
REQUEST QUOTE |
| 90-2542-05 |
The PRI Wire Wrap MAU provides a wire wrap connector (66 posts)
for the 16 port and 8 port PRI cards. It attaches to the rear I/O connectors
of the 7670 ESE & 7350 Shelf (2 AMP/CHAMP 64 posts). This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-2543-01 |
The PRI RJ45 Distribution Panel provides 8 external RJ45
interfaces to the 100 ohm T1 or 120 ohm E1 twisted pair ports of a PRI card.
It may be used with PRI cards 90-4671-x1/x2, 90-2541-x1/x2, 90-2517-x1,
90-2544-x1/x2, and 90-7277-xx. The panel is a 1 vertical unit (VU) high
rack-mountable device. For PRI CE cards (90-2517-x2), use the 90-5930-x1 E1
RJ45 ISDN D.PNL. This panel is shipped with 1VU mid-mount brackets. |
REQUEST QUOTE |
| 90-2543-02 |
The PRI Coax Distribution Panel provides 8 external BNC
interfaces to the 75 ohm E1 coaxial ports of a PRI card. It may be used with
any of the PRI cards (90-2541-x3 or 90-2544-x3). A D.78 cable connects the
PRI card to the panel which provides a BNC connector for each port TX and one
for each port RX. The panel is a 1 vertical unit (VU) high rack-mountable
device. Grounding switches allow the service personnel to independantly
ground any of the coaxial shields. This panel is shipped with 1VU mid-mount brackets. |
REQUEST QUOTE |
| 90-2543-03 |
The PRI Coax Distribution Panel provides 8 front mounted
external BNC interfaces to the 75 ohm E1 coaxial ports of a PRI card. It may
be used with any of the PRI cards (90-2541-x3 or 90-2544-x3). A D.78 cable
connects the PRI card to the panel which provides a BNC connector for each
port TX and one for each port RX. The panel is a 1 vertical unit (VU) high
rack-mountable device. Grounding switches allow the service personnel to
independantly ground any of the coaxial shields. This panel is shipped with 1VU
mid-mount brackets. With the exception of offering front mounted BNC
connectors, this assembly is identical to the 90-2543-02 . |
REQUEST QUOTE |
| 90-2634-01 |
ISDN Basic Rate Distribution Panel |
REQUEST QUOTE |
| 90-2635-01 |
ISDN Primary Rate Distribution Panel |
REQUEST QUOTE |
| 90-2635-02 |
This is the RJ45 distribution panel designed for use with the
Dual E1 Card 3. This distribution panel can support two Dual E1 Card 3 blades
for a total of 4 E1 ports. The cable required for this distribution panel is
part number 90-2693-01 Dual E1 Card 3 Cable. |
REQUEST QUOTE |
| 90-2636-01 |
Daughter card used on the Dual 2.048 MBPS E1 Card
(90-0565-01/08) for ISDN applications where conformance to interim CTR-4
layer one is required. This module is mutually exclusive with the Voice Compr
ession Module (90-0566-01) and the Voice Compression Module-3 (90-0566-04).
Supported by Generic 1116 or greater. |
REQUEST QUOTE |
| 90-2687-01 |
This is a 12 port Four wire transmission only (4WTO) line card.
It is compatible with the existing 4WTO CU on the network connection side.
The 12 circuit 4WTO card is designed for on-premise, 600 Ohm, 4-Wire
applications only where there is no requirement for signaling leads. |
REQUEST QUOTE |
| 90-2693-01 |
This cable assembly is used to connect 90-9244-01 DUAL E1 CARD 3
(75 OHM), and 90-9244-02 DUAL E1 CARD 3 (120 OHM) with the distribution
panel. The part number for the distribution panel is; 90-2635-02 DUAL E1 CARD
3 DISTRIBUTION PANEL. The cable and distribution panel together provide a
means to connect the Dual E1 card circuits to external equipment. |
REQUEST QUOTE |
| 90-2694-01 |
ISDN Dual T1-2 CBL 6FT. |
REQUEST QUOTE |
| 90-2766-01 |
This 1 meter cable connects a 7470 E1 75 PRI CFR QUAD
(90-2544-X3)to a PRI Coax Distribution Panel (90-2543-02). This cable may
also be used to connect a 7470 E1 120 PRI CFR QUAD (90-2544-X2) or E1 PRI VSC
QUAD(90-6757-X2)to a PRI BAL/UNBAL BNC Distribution Panel (90-6398-X1). |
REQUEST QUOTE |
| 90-2766-02 |
This 1 meter cable connects a 7470 E1 75 PRI UFR OCT
(90-2541-X3) E1 75 PRI CR OCT(90-4671-X3) or E1 75 PRI CE OCT (90-2517-X3) to
the PRI Coax Distribution Panel (90-2543-02). This cable may also be used to
connect a 7470 E1 120 PRI UFR OCT (90-2541-X2)E1 CR 120 ATM
CARD(90-4671-X2)or E1 CE 120 8 PORT (90- 2517-X2) to a PRI BAL/UNBAL BNC
Distribution Panel (90-6398-X1) or one side of a 16 port T1/E1 Distribution
Panel (90-8307-X1). |
REQUEST QUOTE |
| 90-2766-21 |
This 3 meter cable connects a 7470 E1 120 PRI CFR QUAD
(90-2544-X2)or E1 PRI VSC QUAD (90-6757-X2) to a PRI BAL/UNBAL BNC
Distribution Panel(90-6398-X1). |
REQUEST QUOTE |
| 90-2766-22 |
This 3 meter cable connects a 7470 E1 120 PRI UFR OCT
(90-2541-X2)E1 CR 120 ATM CARD (90-4671-X2)or E1 CE 120 8 PORT (90-2517-X2)
to a PRI BAL/UNBAL BNC Distribution Panel (90-6398-X1) or one side of a 16
port T1/E1 Distribution Panel (90-8307-X1). |
REQUEST QUOTE |
| 90-2766-31 |
This 10 meter cable connects a 7470 E1 120 PRI CFR QUAD
(90-2544-X2)or E1 PRI VSC QUAD (90-6757-X2) to a PRI BAL/UNBAL BNC
Distribution Panel(90-6398-X1). |
REQUEST QUOTE |
| 90-2766-32 |
This 10 meter cable connects a 7470 E1 120 PRI UFR OCT
(90-2541-X2) E1 CR 120 ATM CARD (90-4671-X2) or E1 CE 120 8 PORT (90
-2517-X2) to a PRI BAL/UNBAL BNC Distribution Panel (90-6398-X1) or one side
of a 16 port T1/E1 Distribution Panel (90-8307-X1). |
REQUEST QUOTE |
| 90-2767-01 |
This 1 meter cable connects a 7470 T1 PRI CFR QUAD (90-2544-X1)
E1 120 PRI CFR QUAD(90-2544-X2) T1 PRI VSC QUAD (90-6757-X1) or E1 PRI VSC
QUAD(90-6757-X2) to a PRI RJ45 Distribution Panel (90-2543-X1). |
REQUEST QUOTE |
| 90-2767-02 |
This 1 meter cable connects a 7470 T1 PRI UFR OCTAL (90-2541-X1)
E1 120 PRI UFR OCT(90-2541-X2)T1 CR ATM CARD (90-4671-X1)E1 CR 120 ATM
CARD(90-4671-X2)T1 CE 8 PORT (90-2517-X1) or E1 CE 120 8 PORT(90-2517-X2) to
a PRI RJ45 D.PNL (90-2543-X1) . |
REQUEST QUOTE |
| 90-2767-11 |
This 3 meter cable connects a 7470 T1 PRI CFR QUAD (90-2544-X1)
E1 120 PRI CFR QUAD(90-2544-X2) T1 PRI VSC QUAD (90-6757-X1) or E1 PRI VSC
QUAD(90-6757-X2) to a PRI RJ45 Distribution Panel (90-2543-X1). |
REQUEST QUOTE |
| 90-2767-12 |
This 3 meter cable
connects a 7470 T1 PRI UFR OCTAL (90-2541-X1 ) E1 120 PRI UFR OCT
(90-2541-X2) T1 CR ATM CARD (90-4671-X1 ) E1 CR 120 ATM CARD (90-4671-X2) T1
CE 8 PORT (90-2517-X1) or E1 CE 120 8 PORT (90-2517-X2) to a PRI RJ45 D.PNL
(90-2543- X1). |
REQUEST QUOTE |
| 90-2767-21 |
This 10 meter cable connects a 7470 T1 PRI CFR QUAD (90-2544-X1
) E1 120 PRI CFR QUAD(90-2544-X2) T1 PRI VSC QUAD (90-6757-X1) or E1 PRI VSC
QUAD(90-6757-X2) to a PRI RJ45 Distribution Panel (90-2543-X1). |
REQUEST QUOTE |
| 90-2767-22 |
This 10 meter cable
connects a 7470 T1 PRI UFR OCTAL (90-2541-X 1) E1 120 PRI UFR OCT
(90-2541-X2) T1 CR ATM CARD (90-4671-X 1) E1 CR 120 ATM CARD (90-4671-X2) T1
CE 8 PORT (90-2517-X1) or E1 CE 120 8 PORT(90-2517-X2) to a PRI RJ45 D.PNL
(90-2543- X1). |
REQUEST QUOTE |
| 90-2843-01 |
Rack containing one 1100W, 100/120 VAC nominal to 48 VDC
rectifier with mounting hardware, power cord and termination hardware for two
rectifiers, as the rack can accomodate two rectifiers for a redundant
configuration. A second rectifier is available by ordering an upgrade kit
(90-2843-02). The rectifier rack is 3 rack units tall (5.25 ) and fits a
standard 19 rack. |
REQUEST QUOTE |
| 90-2843-02 |
A single 1100W 100/120
VAC nominal to 48 VDC rectifier with p ower cord. This rectifier plugs into
the 7470 100/120 VAC to 48 VDC Rectifier rack (90-2843-01). |
REQUEST QUOTE |
| 90-2844-01 |
Rack containing one 1680W, 220/240 VAC nominal to 48 VDC
rectifier with mounting hardware, power cord and termination hardware for two
rectifiers, as the rack can accomodate two rectifiers for a redundant
configuration. A second rectifier is available by ordering an upgrade kit
(90-2844-02). The rectifier rack is 3 rack units tall (5.25 ) and fits a
standard 19 rack. |
REQUEST QUOTE |
| 90-2844-02 |
A single 1680W 220/240
VAC nominal to 48 VDC rectifier with p ower cord. This rectifier plugs into
the 7470 220/240 VAC to 48 VDC Rectifier rack (90-2844-01). |
REQUEST QUOTE |
| 90-2857-01 |
The Test Module is an add on module for the existing Test Card
(90-1235-01) providing these functions: Analog and Digital Tone Test, Bit
Error Rate Test, Bit Errors Insertion, Round Trip Delay Measur ement and DDS
Signaling Test. |
REQUEST QUOTE |
| 90-2865-01 |
The 10BaseT MAU provides an RJ45 8 position modular connector
for the Service Card, providing access to the card's Ethernet port. The
10BaseT MAU attaches to the rear I/O connectors of the Peripheral Shelf. |
REQUEST QUOTE |
| 90-2866-01 |
The Fibre Interface Card (FIC) provides the interface between a
High Speed Peripheral Shelf 2 (HSPS2) Single E3 (SE3) and a fibre E3 trunk.
The FIC provides both the transmit and receive optical paths for one SE3. |
REQUEST QUOTE |
| 90-2892-01 |
Single 2B1Q Module connecting any of the following data
termination units: 2751 RS-232/V.24 DTU, 2752 X.21 DTU, and 2753 V.35 DTU
providing the node S/W supports the DTU. |
REQUEST QUOTE |
| 90-2918-01 |
Identical to 90-2918-01 except tailored for MCI applications. |
REQUEST QUOTE |
| 90-3060-01 |
Oneac Part Number: Order by Description. The 10-DP-1 Single
Series provides lightning protection for 1 two wire copper circuit. The Oneac
single way lightning protector is designed for use with Krone 237A
(90-0080-01/02). To be used in conjunction with the Ground Bar Kit
(90-3061-01). NOTE: Lightning protection is strongly recommended in use with
the LIM Module (HDSL) (90-2380-01/02). |
REQUEST QUOTE |
| 90-3061-01 |
Oneac Part Number: Order by Description. The Oneac Ground Bar
Kit is to be used in conjuction with 10-DP-1 Ten Series TLC (Transmission
Line Cond) (90-3060-01) to provide the required earthing on the Krone Block
(237A) (90-0080-01/02) NOTE: Not required for (90-3059-01). |
REQUEST QUOTE |
| 90-3075-02 |
3600 Release 7.1 S/W Download Key. |
REQUEST QUOTE |
| 90-3076-02 |
3600 Switching Unit Release 7.1 S/W Download Key. |
REQUEST QUOTE |
| 90-3077-02 |
3600 Multi Shelf System Peripheral unit Release 7.1 S/W Download
Key. |
REQUEST QUOTE |
| 90-3078-02 |
3600 E-3 Interface Release 7.1 S/W Download Key. |
REQUEST QUOTE |
| 90-3079-02 |
3600 DS-3 Interface Release 7.1 S/W Download Key. |
REQUEST QUOTE |
| 90-3081-03 |
Downloadable Memory Module Daughter Card, includes software for
NA, UK and International 3600 Release 7.1 products. Requires System Control
Card 3(90-0667-01 or 90-0667-05) mother card. Supports software downloading. |
REQUEST QUOTE |
| 90-3082-03 |
Downloadable Memory Module Daughter Card, includes software for
NA, UK and International 3600 Release 7.1 products. Requires System Control
Card 3(90-0667-01 or 90-0667-05) mother card. Supports software downloading. |
REQUEST QUOTE |
| 90-3083-03 |
Downloadable Memory Module Daughter Card, includes software for
NA, UK and International 3600 Release 7.1 products. Requires System Control
Card 3(90-0667-01 or 90-0667-05) mother card. Supports software downloading. |
REQUEST QUOTE |
| 90-3085-02 |
The GFC3 provides a wide range of maintenance functions. Typical
GFC3 applications include monitoring quality of digital data links, and
troubleshooting of data or voice circuits and cabling problems. |
REQUEST QUOTE |
| 90-3085-04 |
The GFC3 provides a wide range of maintenance functions. Typical
GFC3 applications include monitoring quality of digital data links, and
troubleshooting of data or voice circuits and cabling problems. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-3086-03 |
Complete customer documentation package for Generic 1117.1 of
the 3600 MainStreet Bandwidth Manager; Generic C/D/E/H117.1 of the 3645
MainStreet High Speed Bandwidth Manager; Generic Q116.1 of the 3664
MainStreet Fractional Access Multiplexer; and Release 3 of the 36120
MainStreet Packet Transfer Exchange in an 8 1/2 x 11 format. |
REQUEST QUOTE |
| 90-3086-04 |
Complete customer documentation package for Generic 1117.1 of
the 3600 Mainstreet Bandwidth Manager; Generic C/D/E/H117.1 of the 3645
Mainstreet High Speed Bandwidth Manager; Generic Q117.1 of the 3664
Mainstreet Fractional Access Multiplexer; and Release 3.0 of the 36120
Mainstreet Packet Transfer Exchange in a CD ROM format. |
REQUEST QUOTE |
| 90-3152-01 |
An adaptor which physically converts dual BNC to RJ45.
Conversion is physical only, no impedance adaptation. The BNC connections are
male, the RJ45 connection is female. |
REQUEST QUOTE |
| 90-3160-02 |
This kit upgrades FRE and X.25 FRE cards (90-1638-04 and higher)
to support the latest X.25 Release 1.2 functionality. Includes 3.5 diskette. |
REQUEST QUOTE |
| 90-3162-05 |
The 7470 800M Hub Card can be used in place of a DHUB card in
the Peripheral Shelf Cardfile. The 800M Hub card handles one bi-d irectional
800M ISL link which supports all 12 UCS slots in the shelf. The 800M hub card
is suited for use in peripheral shelves where the total bandwidth of all
interfaces is less than the bandwidth of one ISL. Two 800M Hub Cards are
required per peripheral shelf (for fabric reduncancy) in multi-shelf systems.
This card is delivered with R4.2 application software. This assembly contains
a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-3162-15 |
The 7470 800M Hub Card can be used in place of a DHUB card in
the Peripheral Shelf Cardfile. The 800M Hub card handles one bi-d irectional
800M ISL link which supports all 12 UCS slots in the shelf. The 800M hub card
is suited for use in peripheral shelves where the total bandwidth of all
interfaces is less than the bandwidth of one ISL. Two 800M Hub Cards are
required per peripheral shelf (for fabric reduncancy) in multi-shelf systems. |
REQUEST QUOTE |
| 90-3162-24 |
The Extended ISL (X-ISL) 800M Hub card provides one
bi-directional 800M ISL link supporting all 12 UCS slots in a peripheral
shelf. Two 800M Hub Cards are required per peripheral shelf for fabric
redundancy in multi-shelf systems. This card is delivered with R4.2
application software. X-ISL reach is 15km over customer supplied Single Mode
Fiber. SMF cable requirements are: 9/125 micron core/cladding, 0.35 dB/Km
attenuation at 1310nm, flat polish SC/SC connector. |
REQUEST QUOTE |
| 90-3259-02 |
An integral frame relay switch that plugs into any universal
card slot on the 3600 or 3600+ Mainstreet. A total of 1.92 Mbps of bandwidth
is available between the card and the switching matrix which can be
subdivided into up to 30 channels. The Subrate Interface Module (90-2099-01)
is included and supports subrate speeds that are not multiples of 8 kb/s and
also supports X.50 BIS @ 48 k/bs, X.50 DIV 2,3 and 5, HCM and DDS. |
REQUEST QUOTE |
| 90-3290-32 |
The E3 Unchannelized Frame Relay Card provides a single standar
ds-compliant E3 interface to the 7470 system. This interface terminates one
unchannelized frame relay stream and will perform standards-based frame
switching network-interworking or serv ice-interworking. This card is
delivered with R4.2 software. |
REQUEST QUOTE |
| 90-3290-41 |
The DS3 Unchannelized
Frame Relay Card provides a single standa rds-compliant DS3 interface to the
7470 system. This interface t erminates one unchannelized frame relay stream
and will perfor m standards-based frame switching network-interworking or se
rvice-interworking. This card is deliver ed with R4.2 software. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-3290-42 |
The E3 Unchannelized Frame Relay Card provides a single standar
ds-compliant E3 interface to the 7470 system. This interface terminates one
unchannelized frame relay stream and will perform standards-based frame
switching network-interworking or serv ice-interworking. |
REQUEST QUOTE |
| 90-3290-51 |
The DS3 Unchannelized Frame Relay Card provides a single standa
rds-compliant DS3 interface to the 7470 system. This interface t erminates
one unchannelized frame relay stream and will perfor m standards-based frame
switching network-interworking or se rvice-interworking. |
REQUEST QUOTE |
| 90-3346-07 |
The Control Card 2 implements the control complex functions for
the node. The Control Card 2 provides two RS-232 ports node management (local
and/or remote NMTI), and one Ethernet 10BaseT interface port for network
management system access. One Control Card is required for non-redundant
control complex and two for control complex redundancy per 36170 system. Node
management, alarm, and timing termination require a control card interconnect
panel (CCIP). One CCIP serves both active and redundant control cards. There
are two variants of CCIP for US Telco (90-2295-x1) and International
(90-2295-x2) requirements. This card is delivered with R4.3 software, and
with an enhanced Processor Module (ePM), and with a NAND-based 256MB memory
card. Note that previous to this note, all control cards were shipped wih
NOR-based memory cards. The software loadset required for this card is
documented in Field Notice FN1867. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-3346-17 |
The Control Card 2 implements the control complex functions for
the node. The Control Card 2 provides two RS-232 ports node management (local
and/or remote NMTI), and one Ethernet 10BaseT interface port for network
management system access. One Control Card is required for non-redundant
control complex and two for control complex redundancy per 7470 system. Node
management, alarm, and timing termination require a control card interconnect
panel (CCIP). One CCIP serves both active and redundant control cards. There
are two variants of CCIP for US Telco (90-2295-x1) and International
(90-2295-x2)requirements. This card is delivered with R5.0 software and with
an enhanced Processor. |
REQUEST QUOTE |
| 90-3346-27 |
CONTROL CARD-2 W/EPM |
REQUEST QUOTE |
| 90-3346-41 |
The Control Card 2 implements the control complex functions for
the node. The Control Card 2 provides two RS-232 ports node management (local
and/or remote NMTI), and one Ethernet 10BaseT interface port for network
management system access. One Control Card is required for a non-redundant
control complex and two for control complex redundancy per 36170 system. Node
management, alarm, and timing termination require a control card interconnect
panel (CCIP). One CCIP serves both active and redundant control cards. There
are two variants of CCIP for US Telco (90-2295-x1) and International
(90-2295-x2) requirements. This card is delivered with R4.3 software. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-3347-01 |
The Stratum 3 SSU-2
Module provides Stratum 3 timing synchroniz ation to an incoming timing
signal for the 7470 system. The Stra tum 3 SSU-2 Module is an optional module
for the Control Card 2 (90-3346-01) INTEG CALLP/PNNI CARD-2 R3.1 (90-6226-X1)
and INTEG CALLP CARD-2/R3.1 (90-6226-X2). This assembly contains a Telcordia
CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-3553-11 |
The DS3 Channelized Frame
Relay Card provides a single standard s-compliant DS3 interface to the 7470
system. This interface ter minates 256 frame relay streams and will perform
standards-bas ed frame switching network-interworking or service-interwork
ing. This card requires Release 4.2 for operational support and is delivered
with R4.2 application software. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-3553-21 |
The DS3 Channelized Frame Relay Card provides a single standard
s-compliant DS3 interface to the 7470 system. This interface ter minates 256
frame relay streams and will perform standards-bas ed frame switching
network-interworking or service-interwork ing. |
REQUEST QUOTE |
| 90-3598-34 |
The Extended ISL (X-ISL) Dual Switching Card is a scalable cell
switching fabric card which provides the transmit interface for two 800 Mbps
X-ISL links. The X-ISL Dual Receiver Card terminates the two corresponding
X-ISL link receive interfaces. One to eight Dual Switching shelf to support
from 1.6 Gbps to 12.8 Gbps fabric capacity. This card is delivered with R4.2
application software. X-ISL reach is 15km over customer supplied Single Mode
Fiber. SMF cable requirements are: 9/125 micron core/claddind, 0.35 dB/Km
attenunation at 1310nm, flat polish SC/SC connector. |
REQUEST QUOTE |
| 90-3598-35 |
The Dual Switching Card is a scalable cell switching fabric card
which can terminate the transmit interface of up to two 800 Mbps ISL links.
The associated Dual Receiver Card terminates the ISL link received interface.
One to eight Dual Switching Cards can be installed in the Switching Shelf
Cardfile to create cell fabrics of 1.6 Gbps to 12.8 Gbps. This card is
delivered with R4.2 software. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-3598-45 |
The Dual Switching Card is a scalable cell switching fabric card
which can terminate the transmit interface of up to two 800 Mbps ISL links.
The associated Dual Receiver Card terminates the ISL link received interface.
One to eight Dual Switching Cards can be installed in the Switching Shelf
Cardfile to create cell fabrics of 1.6 Gbps to 12.8 Gbps. |
REQUEST QUOTE |
| 90-3623-02 |
This kit provides node software for the current maintenance
version of 36LG Rel 7.1. Includes CD ROM. |
REQUEST QUOTE |
| 90-3669-03 |
DC dual input power shelf with front panel indicators displaying
power supply status and alarms. Does not contain a power supply. Can
accomodate one or two PWR SUPPLY -48/60VDC (90-9524-02) or one power supply
and one Mainstreet RINGER PSU (90-5946-01). Power Tray includes NA power
cord. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-3669-11 |
87 to 264 VAC single input power shelf with front panel
indicators displaying power supply status and alarms. Does not contain a
power supply. Can accomodate one or two 87/264 VAC power supplies(90-9524-01)
or one power supply and one Mainstreet RINGER PSU(90-5946-01). This part
replaces 90-3669-01 and 90-3669-05. Power Tray includes NA power cord and
EU(pig tail) power cord. |
REQUEST QUOTE |
| 90-3669-12 |
87 to 264 VAC dual input power shelf with front panel indicators
displaying power supply status and alarms. Does not contain a power supply.
Can accomodate one or two 87/264 VAC power supplies (90-9524-01) or one power
supply and one Mainstreet RINGER PSU (90-5946-01). this part replaces
90-3669-02 and 90-3669-06. Power Tray includes NA power cord and EU (pig
tail) power cord. |
REQUEST QUOTE |
| 90-3674-01 |
A front cover assembly for the 19 36LG shelf that is required
for EMC compliance when high power cards (ie PE, FRE, DSP5) are used in a
card shelf (90-0010-10, 90-0010-13, 90-0010-14). |
REQUEST QUOTE |
| 90-4442-01 |
The 6 slot DC system is
suitable for desktop or 19in and 23in r ackmount. It can be configured for
redundant or non redundant co ntrol and fabric supporting 4 or 5 universal
card slots respecti vely. Each system can support from 1 to 3 DC power
supplies depe nding on system configuration and power supply redundancy
requir ements. The system comes with a fan unit air filters and blank ing
panels.3 This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4442-02 |
The 8 slot DC system is
suitable for desktop 19in rackmount o r 23in rackmount. It can be configured
for redundant or non-redu ndant control and fabric supporting 7 or 8
universal card slots respectivel y. Each system can support from 1 to 5 DC
power supp lies depending on system configuration and power supply redundan
cy requirements. The system comes with a fan unit air filters and blanking
panels. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4443-01 |
A single 150 watt AC power supply that auto ranges to cover both
100/120 VAC and 220/240 VAC. The supply allows hot swapping and load sharing.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4444-01 |
A single 150 watt 48/60 VDC power supply. The supply allows hot
swapping and load sharing. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4445-01 |
This unit is a
replacement integrated fan unit for the 7270. It contains 6 fans integrated
fan speed control and LED status p anel. |
REQUEST QUOTE |
| 90-4445-02 |
This unit is a replacement integrated fan unit for the 8 slot
7270. It contains 6 fans, integrated fan speed control and LED status panel. |
REQUEST QUOTE |
| 90-4446-01 |
This package contains 10
main and 10 power supply air filters. |
REQUEST QUOTE |
| 90-4446-02 |
This package contains 10
main and 10 power supply air filters f or the 7270 8 slot systems. |
REQUEST QUOTE |
| 90-4447-01 |
The unit is a replacement
fan for both AC and DC power supply u nit. |
REQUEST QUOTE |
| 90-4448-01 |
This unit is a
replacement control I/o card. It provides ethern et and RS-232 ports for the
control card(s). |
REQUEST QUOTE |
| 90-4449-01 |
The spare Blank UCS Card
Pair provides 1 blank front panel and 1 blank back panel for the 7270 system. |
REQUEST QUOTE |
| 90-4450-01 |
This package provides
spares for parts that are currently shipp ed with the 7270 shelves. It
contains a power cord rubber feet PCMCIA card covers blank faceplates for
BITs Alarm and Co ntrol i/o c ard and 19in and 23in mounting rails and
screws. |
REQUEST QUOTE |
| 90-4451-01 |
A 2.048 MHz reference clock input accepts redundant signals used
to synchronize the switch to external clock sources. The card uses a BNC
connector. |
REQUEST QUOTE |
| 90-4451-02 |
A 2.048 MHz reference clock outputs redundant signals used to
synchronize external equipment to the switch. The card uses a BNC connector. |
REQUEST QUOTE |
| 90-4451-03 |
A 1.544 MHz reference clock input accepts redundant signals used
to synchronize the switch to external clock sources. The card uses wire wrap
pins. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4452-13 |
This kit is used to upgrade a 7270 control card to the enhanced
Processor Module(ePM) and larger (96M)SanDisk. Beginning in R5.0 7270control
cards ship with the ePM installed, and with the larger SanDisk included, and
do not require this upgrade kit. This kit contains an ePM(333 MHz PowerPC 755
module with 256M RAM), 96M SanDisk, part number labels and instructions for
installation. |
REQUEST QUOTE |
| 90-4452-31 |
The Control Card implements the control complex functions of the
node, including call processing and PNNI. The Control Card provides two
RS-232 ports for node management (local and/or remote NMTI), and one Ethernet
10BaseT interface port for network management system access. One card is
required for non-redundant operation, and two for redundancy per 7270 system.
This card must be installed in Control Card slots only. This card is
delivered with R4.3 software. Each control card must be used in conjunction
with a hub card (90-4453-03). This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4452-42 |
This Control Card implements the control complex functions of
the node, including call processing and PNNI. The Control Card provides two
RS-232 ports for node management (local and/or remote NMTI), and one Ethernet
10BaseT interface port for network management system access. One card is
required for non-redundant operation, and two cards for redundancy per 7270
system. This card must be installed in Control Card slots only. This card is
delivered with R5.0 software and with an enhanced Processor Module (ePM).
Each control card must be used in conjunction with a hub card (90-4453-03).
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4452-49 |
This Control Card implements the control complex functions of
the node, including call processing, PNNI, and data spooling. The Control
Card provides two RS-232 ports for node management (local and/or remote
NMTI), and one Ethernet 10BaseT interface port for network management system
access. One card is required for non-redundant operation, and two cards for
redundancy per 7270 system. This card must be installed in Control Card slots
only. This card is delivered with R5.0 software and with an enhanced Processor
Module (ePM). Each control card must be used in conjunction with a hub card
(90-4453-03). |
REQUEST QUOTE |
| 90-4452-52 |
This Control Card implements the control complex functions of
the node,including call processing and PNNI. The Control Card provides two
RS-232 ports for node management (local and/or remote NMTI), and one Ethernet
10BaseT interface port for network management system access. One card is
required for non-redundant operation,and two cards for redundancy per 7270
system. This card must be installed in Control Card slots only. This card is
delivered with R6.0 software and with an enhanced Processor Module (ePM).Each
control card must be used in conjunction with a hub card. |
REQUEST QUOTE |
| 90-4452-52 |
This Control Card implements the control complex functions of
the node,including call processing and PNNI. The Control Card provides two
RS-232 ports for node management (local and/or remote NMTI), and one Ethernet
10BaseT interface port for network management system access. One card is
required for non-redundant operation,and two cards for redundancy per 7270
system. This card must be installed in Control Card slots only. This card is
delivered with R6.0 software and with an enhanced Processor Module (ePM).Each
control card must be used in conjunction with a hub card. |
REQUEST QUOTE |
| 90-4452-59 |
This Control Card implements the control complex functions of
the node,including call processing, PNNI, and data spooling. The Control Card
provides two RS-232 ports for node management (local and/or remote NMTI),and
one Ethernet 10BaseT interface port for network management system access. One
card is required for non-redundant operation, and two cards for redundancy
per 7270 system. This card must be installed in Control Card slots only. This
card is delivered with R6.0 software and with an enhanced Processor Module
(ePM). Each control card must be used in conjunction with a hub card. |
REQUEST QUOTE |
| 90-4452-59 |
This Control Card implements the control complex functions of
the node,including call processing, PNNI, and data spooling. The Control Card
provides two RS-232 ports for node management (local and/or remote NMTI),and
one Ethernet 10BaseT interface port for network management system access. One
card is required for non-redundant operation, and two cards for redundancy
per 7270 system. This card must be installed in Control Card slots only. This
card is delivered with R6.0 software and with an enhanced Processor Module
(ePM). Each control card must be used in conjunction with a hub card. |
REQUEST QUOTE |
| 90-4453-03 |
The 7270 Hub card is the
common equipment card that provides lo cal switching capability. The Hub
handles 800M transmit and rece ive non blocking switching. For a
non-redundant fabric one Hub card is required. For a redundant fabric two Hub
cards are re quired. This version of HUB card can be used interchangeably in
both 6 and 8 slot systems. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4454-11 |
The T1 4 port Channelized Frame Relay card provides 4 DS1 ports.
Each port is channelized down to the DS0 rate. Supports up to 2000 frame
relay connections per card. Perform frame relay to ATM Network Interworking
and Service Interworking. This card is delivered with R4.2 software. |
REQUEST QUOTE |
| 90-4454-12 |
The E1 4 port Channelized Frame Relay card provides 4 E1 ports.
Each port is channelized down to 64kb/sec rate. Supports up to 2000 frame
relay connections per card. Perform frame relay to ATM Network Interworking
and Service Interworking. This card is delivered with R4.2 software. |
REQUEST QUOTE |
| 90-4455-21 |
The 8 Port T1 Circuit Emulation Card multiplexes/demultiplexes
the circuits carried over a TDM channelized link and performs the necessary
operations to allow the transport of these circuits through an ATM network.
This card supports both structured and unstructured service as defined by the
ATM Forum. It also provides CAS pass-through or clear channel capability.
This card is delivered with R4.3 software. This assembly contains a Telcordia
CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4455-22 |
The 8 Port E1 Circuit Emulation Card multiplexes/demultiplexes
the circuits carried over a TDM channelized link and performs the necessary
operations to allow the transport of these circuits through an ATM network.
This card supports both structured and unstructued service as defined by the
ATM Forum. It optionally provides CAS pass-through or clear channel
capability. This card is delivered with R4.3 software. |
REQUEST QUOTE |
| 90-4456-02 |
The OC3-2M UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The OC3-2M is a single port card compliant to the requirements of the
ATM Forum UNI Specification (Version 3.1) and the ATM Forum B-ICI
Specification (Version 2.0). This OC3 card provides 16K connections per port.
This card is designed to accept the optional Multi-Service Traffic Shaping
Module (MTSM, 90-6744-02) or enhanced Traffic Shaping Module (eTM,
90-7695-01) which, when installed, provides enhanced traffic management
features. This card must be used in conjunction with an I/O module
(90-4462-xx). This card is shipped with R4.3 software. This assembly contains
a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4456-12 |
The OC3-2M UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The OC3-2M is a single port card compliant to the requirements of the
ATM Forum UNI Specification (Version 3.1) and the ATM Forum B-ICI
Specification (Version 2.0). This OC3 card provides 16K connections per port.
This card is designed to accept the optional Multi-Service Traffic Shaping
Module (MTSM, 90-6744-02) or enhanced Traffic Shaping Module (eTM,
90-7695-01) which, when installed, provides enhanced traffic management
features. This card must be used in conjunction with an I/O module
(90-4462-xx). This card is shipped with R5.0 software. |
REQUEST QUOTE |
| 90-4456-22 |
The OC3-2M UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The OC3-2M is a single port card compliant to the requirements of the
ATM Forum UNI Specification (Version 3.1) and the ATM Forum B-ICI
Specification (Version 2.0). This OC3 card provides 16K connections per port.
This card is designed to accept the optional Multi-Service Traffic Shaping
Module (MTSM, 90-6744-02) or enhanced Traffic Shaping Module (eTM,
90-7695-01)which, when installed, provides enhanced traffic management
features. This card must be used in conjunction with an I/O module
(90-4462-xx). This card is shipped with R6.0 software. |
REQUEST QUOTE |
| 90-4457-02 |
The STM1-2M UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SDH STM1 rate of 155 Mbps, with 32k cell buffering per card.
The STM1-2M is a single port card compliant to the requirements of the ATM
Forum UNI Specification (Version 3.1) and the ATM Forum B-ICI Specification
(Version 2.0). This STM1 card provides 16K connections per port. This card is
designed to accept the optional Multi-Service Traffic Shaping Module (MTSM,
90-6744-02) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enhanced traffic management features. This card must be
used in conjunction with an I/O module (90-4462-xx). This card is shipped
with R4.3 software. |
REQUEST QUOTE |
| 90-4457-12 |
The STM1-2M UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SDH STM1 rate of 155 Mbps, with 32k cell buffering per card.
The STM1-2M is a single port card compliant to the requirements of the ATM
Forum UNI Specification (Version 3.1) and the ATM Forum B-ICI Specification
(Version 2.0). This STM1 card provides 16K connections per port. This card is
designed to accept the optional Multi-Service Traffic Shaping Module (MTSM,
90-6744-02) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enhanced traffic management features. This card must be
used in conjunction with an I/O module (90-4462-xx). This card is shipped
with R5.0 software. |
REQUEST QUOTE |
| 90-4457-22 |
The STM1-2M UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SDH STM1 rate of 155 Mbps, with 32k cell buffering per card.
The STM1-2M is a single port card compliant to the requirements of the ATM
Forum UNI Specification (Version 3.1) and the ATM Forum B-ICI Specification
(Version 2.0). This STM1 card provides 16K connections per port. This card is
designed to accept the optional Multi-Service Traffic Shaping Module
(MTSM,90-6744-02) or enhanced Traffic Shaping Module (eTM, 90-7695-01)which,
when installed, provides enhanced traffic management features. This card must
be used in conjunction with an I/O module (90-4462-xx). This card is shipped
with R6.0 software. |
REQUEST QUOTE |
| 90-4458-13 |
The DS3 UNI/NNI card is a three port ATM interface card. Each
port operates at 45Mbps. The DS3 card is fully compliant to the mandatory
requirements of the ATM Forum UNI specification (version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-6744-02) or enhanced
Traffic Shaping Module (eTM, 90-7695-01) which, when installed, provides
enhanced traffic management features. This card must be used in conjunction
with an I/O module (90-4463-xx). This card is shipped with R4.3 software. |
REQUEST QUOTE |
| 90-4458-14 |
The E3 UNI/NNI card is a three port ATM interface card. Each
port operates at 34Mbps. The E3 card is fully compliant to the mandatory
requirements of the ATM Forum UNI specification (version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-6744-02) or enhanced
Traffic Shaping Module (eTM, 90-7695-01) which, when installed, provides
enhanced traffic management features. This card must be used in conjunction
with an I/O module (90-4463-xx). This card is shipped with R4.3 software. |
REQUEST QUOTE |
| 90-4458-15 |
The DS3 UNI/NNI card is a three port ATM interface card. Each
port operates at 45Mbps. The DS3 card is fully compliant to the mandatory
requirements of the ATM Forum UNI specification (version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This DS3 card provides 4.5K
connections per port. This card is designed to accept the optional
Multi-Service Traffic Shaping Module (MTSM, 90-6744-02) or enhanced Traffic
Shaping Module (eTM, 90-7695-01) which, when installed, provides enhanced
traffic management features. This card must be used in conjunction with an
I/O module (90-4463-xx). This card is shipped with R5.0 software. |
REQUEST QUOTE |
| 90-4458-16 |
The E3 UNI/NNI card is a three port ATM interface card. Each
port operates at 34Mbps. The E3 card is fully compliant to the mandatory
requirements of the ATM Forum UNI specification (version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This E3 card provides 4.5K
connections per port. This card is designed to accept the optional
Multi-Service Traffic Shaping Module (MTSM, 90-6744-02) or enhanced Traffic
Shaping Module (eTM, 90-7695-01) which, when installed, provides enhanced
traffic management features. This card must be used in conjunction with an
I/O module (90-4463-xx). This card is shipped with R5.0 software. |
REQUEST QUOTE |
| 90-4458-25 |
The DS3 UNI/NNI card is a three port ATM interface card. Each
port operates at 45Mbps. The DS3 card is fully compliant to the mandatory
requirements of the ATM Forum UNI specification (version 3.1) and the ATM
Forum B-ICI Specification (Version2.0). This DS3 card provides 4.5K
connections per port. This card is designed to accept the optional
Multi-Service Traffic Shaping Module (MTSM,90-6744-02) or enhanced Traffic
Shaping Module (eTM, 90-7695-01)which, when installed, provides enhanced
traffic management features. This card must be used in conjunction with an
I/O module (90-4463-xx). This card is shipped with R6.0 software. |
REQUEST QUOTE |
| 90-4458-26 |
The E3 UNI/NNI card is a three port ATM interface card. Each
port operates at 34Mbps. The E3 card is fully compliant to the mandatory
requirements of the ATM Forum UNI specification (version 3.1) and the ATM
Forum B-ICI Specification (Version2.0). This E3 card provides 4.5K
connections per port. This card is designed to accept the optional
Multi-Service Traffic Shaping Module (MTSM,90-6744-02) or enhanced Traffic
Shaping Module (eTM, 90-7695-01)which, when installed, provides enhanced
traffic management features. This card must be used in conjunction with an
I/O module (90-4463-xx). This card is shipped with R6.0 software. |
REQUEST QUOTE |
| 90-4459-23 |
This card provides eight T1 ports for Cell Relay (ATM) services
on the 7270, with 32k cell buffering per card and advanced traffic management
capability. This card allows an optional upgrade module (90-6743-01) to
provide up to four groups of ATM Inverse Multiplexing. This card must be used
in conjunction with an I/O module (90-4460-01). This card is shipped with
R4.3 software. |
REQUEST QUOTE |
| 90-4459-24 |
This card provides eight E1 ports for Cell Relay (ATM) services
on the 7270, with 32k cell buffering per card and advanced traffic management
capability. This card allows an optional upgrade module (90-6743-01) to
provide up to four groups of ATM Inverse Multiplexing. This card must be used
in conjunction with an I/O module (90-4460-02 or 90-4460-03). This card is
shipped with R4.3 software. |
REQUEST QUOTE |
| 90-4459-33 |
This card provides eight T1 ports for Cell Relay (ATM) services
on the 7270, with 32k cell buffering per card and advanced traffic management
capability. This card allows an optional upgrade module (90-6743-01) to
provide up to four groups of ATM Inverse Multiplexing. This card must be used
in conjunction with an I/O module (90-4460-01). This card is shipped with
R5.0 software. |
REQUEST QUOTE |
| 90-4459-34 |
This card provides eight E1 ports for Cell Relay (ATM) services
on the 7270, with 32k cell buffering per card and advanced traffic management
capability. This card allows an optional upgrade module (90-6743-01) to
provide up to four groups of ATM Inverse Multiplexing. This card must be used
in conjunction with an I/O module (90-4460-02 or 90-4460-03). This card is
shipped with R5.0 software. |
REQUEST QUOTE |
| 90-4459-43 |
This card provides eight T1 ports for Cell Relay (ATM) services
on the 7270,with 32k cell buffering per card and advanced traffic management
capability. This card allows an optional upgrade module (90-6743-01)to
provide up to four groups of ATM Inverse Multiplexing. This card must be used
in conjunction with an I/O module (90-4460-01). This card is shipped with
R6.0 software. |
REQUEST QUOTE |
| 90-4459-44 |
This card provides eight E1 ports for Cell Relay (ATM) services
on the 7270,with 32k cell buffering per card and advanced traffic management
capability. This card allows an optional upgrade module (90-6743-01)to
provide up to four groups of ATM Inverse Multiplexing. This card must be used
in conjunction with an I/O module (90-4460-02 or 90-4460-03).This card is
shipped with R6.0 software. |
REQUEST QUOTE |
| 90-4460-01 |
The T1 I/O card provides 8 ports that may be software-configured
as an off-premise (DS-1) or on-premise (DSX-1) interface using RJ45
connectors. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4460-02 |
The E1 I/O card provides 8 ports of 120 ohm twisted pair
interface, using RJ45 connectors. |
REQUEST QUOTE |
| 90-4460-03 |
The E1 I/O card provides 8 ports of 75 ohm coaxial cable
interface, using BNC connectors. |
REQUEST QUOTE |
| 90-4461-01 |
The T1 I/O card provides 4 ports that may be software-configured
as an off-premise (DS-1) or on-premise (DSX-1) interface using RJ45
connectors. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4461-02 |
The E1 I/O card provides 4 ports of 120 ohm twisted pair
interface, using RJ45 connectors. |
REQUEST QUOTE |
| 90-4461-03 |
The E1 I/O card provides 4 ports of 75 ohm coaxial cable
interface, using BNC connectors. |
REQUEST QUOTE |
| 90-4462-01 |
The OC3/STM1 Short Reach I/O card provides the multimode fiber
interface using SC connectors. The interface has a typical range of 2km. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-4462-02 |
The OC3/STM1 Intermediate Reach I/O card provides single mode
fiber interface using SC connectors. The interface uses 1310nm laser and has
a total loss budget of 12dB. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4462-03 |
The OC3/STM1 Long Reach I/O card provides single mode fiber
interface using SC connectors. The interface uses 1310nm laser and has a
total loss budget of 28dB. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4462-06 |
The OC3/STM1 CMI BNC I/O card provides coaxial cable interface
using a BNC connector. |
REQUEST QUOTE |
| 90-4463-01 |
The DS3/E3 3 Port BNC I/O card provides coaxial cable interface
using a BNC connector. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4463-04 |
The DS3/E3 single port BNC I/O card provides co-axial cable
interface using a BNC connector. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4464-01 |
This unit provides separate dry contact relay outputs for
critical, major, minor, audible and visible alarms. It also provides 6
independant external alarm sensor inputs. In the DC system also monitors for
the 48/60 VDC A and B feeds. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4521-43 |
Technical Practices for R4.3 of the 7270 |
REQUEST QUOTE |
| 90-4521-50 |
Technical Practices for
R5.0 of the 7270 |
REQUEST QUOTE |
| 90-4521-60 |
Technical Practices for R6.0 of the 7270 |
REQUEST QUOTE |
| 90-4521-60 |
Technical Practices for R6.0 of the 7270 |
REQUEST QUOTE |
| 90-4653-01 |
The Voiceband Services Card (VSC) terminates TDM channels at its
T1 ports, and provides features including speech compression, silence
removal, and fax demodulation to adapt these TDM channels to transport over
an ATM network. The VSC requires a minimum of one (typical applications
require three) and a maximum of four DSP1 transport modules per 90-4654-02.
Fits 7270 midplane. Requires I/O card per 90-4461-01 |
REQUEST QUOTE |
| 90-4653-02 |
The Voiceband Services Card (VSC) terminates TDM channels at its
E1 ports, and provides features including speech compression, silence
removal, and fax demodulation to adapt these TDM channels to transport over
an ATM network. The VSC requires a minimum of one (typical applications
require three) and a maximum of four DSP1 transport modules per 90-4654-02.
Fits 7270. Requires I/O card per 90-4461-02, -03, or –04. |
REQUEST QUOTE |
| 90-4654-02 |
VSC DSP1 Transport Module: Supports up to 40 voice channels,
i.e. 40 channels of either G.729A (CS ACELP), G.711 (PCM), G.726 (ADPCM),
NetCoder, or clear channel. Provides silence suppression, idle channel
detection, and integrated echo cancellation of up to 30 ms tail length per
channel. Note: At least one VSC DSP1 module must be installed on every
Voiceband Service Card 90-4653-xx 90-6757-xx See also: 90-4654-01 This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-4672-01 |
This module provides the Inverse Multiplexing for ATM capability
for the T1/E1 ATM Cell Relay interface cards (90-6351-0x). The module
supports either ATM Forum IMA v1.0 or v1.1 through separate software loads.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4686-01 |
This CD is a 7470 MSP Technical Practices Library. |
REQUEST QUOTE |
| 90-4690-21 |
The E3 Channelized Circuit Emulation Card provides a single 34
Mb/s TDM interface. The E3 port is channelized into 16 E1 channels. The card
performs the ATM adaption function to map each of the 16 channels into ATM
virtual circuits. The card is shipped with the DS3/E3 SWITCHING MAU
(90-4919-01) which provides two pairs of coaxial connectors. This card is
delivered with R4.0 application software. |
REQUEST QUOTE |
| 90-4716-01 |
This cable kit will allows power trays 90-3669-11, 90-3669-12,
and 90-3669-03 to be installed into MainStreet 3600 shelf 90-0010-10 having
manufacturing code E or less. |
REQUEST QUOTE |
| 90-4716-02 |
This cable kit will allows power trays 90-3669-11, 90-3669-12,
and 90-3669-03 to be installed into MainStreet 3600 MSS shelf 90-0662-03
having manufacturing code E or less and MainStreet 3600 MSS shelf 90-0652-01
having manufacturing code E or less. |
REQUEST QUOTE |
| 90-4724-01 |
The 7470 Multi-Service Traffic Shaping Module (MTSM) is an
optional module on cell-relay line cards designed to accept it (e.g. OC3-2).
When installed it provides an additional 200K cells of buffering, per-VC
queueing, per-VC shaping, ABR Virtual Source/Virtual Destination and other
traffic management enhancements. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4900-05 |
Basic system that provides to a single E1 (2.048Mb/s) high speed
optical link interface when installed with 90-0568-08 optical LIM module.
(must be ordered separately). Also included is a secondary E1 PRI interface
that must configured with a standard LIM or HDSL LIMS. (LIMS must be ordered
separately) Includes 240VAC power supply (90-0417-01), common control card
(90-4901-01). software generic 91x5 (90-0562-07), universal card
(90-0413-01), and display assembly. System documentat ion (90-0433-03) and ringing
generators (90-0578-01) (qty 2 per system) also must be order separately. |
REQUEST QUOTE |
| 90-4905-1A |
The OC3-2M IR UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The Intermediate Reach(IR) single mode fiber optical interface has a
total loss budget of 12db. The OC3-2M IR is a single port card compliant to
the requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced
Traffic Shaping Module (eTM,90-7695-01) which, when installed, provides
enhanced traffic management features. This card variant is shipped with R4.3
S/W. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4905-1B |
The OC3-2M LR UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The Long Reach (LR) single mode fiber optical inerface has a total loss
budget of 28db. The OC3-2M LR is a single port card compliant to the
requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced
Traffic Shaping Module (eTM, 90-7695-01) which, when installed, provides
enhanced traffic management features. This card variant is shipped with R4.3
S/W. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4905-1C |
The OC3-2M MMF Card with CPU-2 is a local ATM (LATM) OC3
interface card operating at the SONET OC3 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF) optional interface has a
typical range of 2km. The OC3-2M MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification (Version
3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card is
designed to accept the optional Multi-Service Traffic Module (MSTM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enchanced traffic management features. This card variant
is shipped with R4.3 S/W. |
REQUEST QUOTE |
| 90-4905-2A |
The OC3-2M IR UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The Intermediate Reach(IR) single mode fiber optical interface has a
total loss budget of 12db. The OC3-2M IR is a single port card compliant to
the requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced
Traffic Shaping Module (eTM,90-7695-01) which, when installed,provides
enhanced traffic management features. This card variant is shipped with R5.0
S/W. This card is also supported on R2.0 of the 7670 ESE shelf. Note that
only the eTM is supported for traffic shaping on the ESE. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4905-2B |
The OC3-2M LR UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The Long Reach (LR) single mode fiber optical inerface has a total loss
budget of 28db. The OC3-2M LR is a single port card compliant to the
requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced
Traffic Shaping Module (eTM, 90-7695-01) which, when installed, provides
enhanced traffic management features. This card variant is shipped with R5.0
S/W. This card is also supported on R2.0 of the 7670 ESE. Note that only the
eTM is supported for traffic shaping on the ESE. This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4905-2C |
The OC3-2M MMF Card with CPU-2 is a local ATM (LATM) OC3
interface card operating at the SONET OC3 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF) optional interface has a
typical range of 2km. The OC3-2M MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification (Version
3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card is
designed to accept the optional Multi-Service Traffic Module (MSTM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enchanced traffic management features. This card variant
is shipped with R5.0 S/W. This card is also supported on R2.0 of the 7670
ESE. Note that only the eTM is supported for traffic shaping on the ESE. |
REQUEST QUOTE |
| 90-4905-30 |
The OC3-2 XLR UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The transmit and receive wavelength of the XLR card is 1550 nm and
supports up to 10km of fiber. The OC3-2 XLR is a single port card compliant
to the requirements of the ATM Forum UNI Specification (Version 3.1) and the
ATM Forum B-ICI Specification (Version 2.0). Requires a minimum of Release
3.1 for operational support. This card is designed to accept the optional
Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) which when installed,
provides enhanced traffic management features. This card variant is shipped
with R4.3 S/W. |
REQUEST QUOTE |
| 90-4905-3A |
The OC3-2M IR UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The Intermediate Reach(IR) single mode fiber optical interface has a
total loss budget of 12db. The OC3-2M IR is a single port card compliant to
the requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced
Traffic Shaping Module (eTM,90-7695-01) which, when installed,provides
enhanced traffic management features. This card is also supported on R2.0 of
the 7670 ESE shelf. Note that only the eTM is supported for traffic shaping
on the ESE. |
REQUEST QUOTE |
| 90-4905-3B |
The OC3-2M LR UNI/NNI Card with CPU-2 is an ATM interface card
operating at the SONET OC3 rate of 155 Mbps, with 32k cell buffering per
card. The Long Reach (LR) single mode fiber optical inerface has a total loss
budget of 28db. The OC3-2M LR is a single port card compliant to the
requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is designed to accept the
optional Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced
Traffic Shaping Module (eTM, 90-7695-01) which, when installed, provides
enhanced traffic management features. This card is also supported on R2.0 of
the 7670 ESE. Note that only the eTM is supported for traffic shaping on the
ESE. |
REQUEST QUOTE |
| 90-4905-3C |
The OC3-2M MMF Card with CPU-2 is a local ATM (LATM) OC3
interface card operating at the SONET OC3 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF) optional interface has a
typical range of 2km. The OC3-2M MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification (Version
3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card is
designed to accept the optional Multi-Service Traffic Module (MSTM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enchanced traffic management features. This card is also
supported on R2.0 of the 7670 ESE. Note that only the eTM is supported for
traffic shaping on the ESE. |
REQUEST QUOTE |
| 90-4905-48 |
The OC3-2 MMF Card with CPU-2 is a local ATM (LATM) OC3
interface card operating at the SONET OC3 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF)optional interface has a
typical range of 2km. The OC3-2 MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification (Version
3.1) and the ATM Forum B-ICI Specification (Version 2.0). Requires a minimum
of Release 3.1 for operational support. This card is designed to accept the
optional Multi-Service Traffic Module (MSTM 90-4724-01) or enhanced Traffic
Shaping Module (eTM, 90-7695-01) which, when installed, provides enchanced
traffic management features. MD EFFECTIVITY DATE = AUGUST 1, 2004 AS PER PDN
9199. |
REQUEST QUOTE |
| 90-4906-01 |
This kit is used to: 1) Upgrade a R1.3, R2.1, or R2.2 DS3 ATM
UNI/NNI card or Triple E3 ATM card to support release 2.3 and higher. Factory
shipments of DS3/E3 R2.2 and higher cards, 90-2189-21/31/41 and
90-2294-21/31/41, ship with the memory module 2 installed and do not require
this upgrade kit. 2) Upgrade a R1.3, R2.1,R2.2, or R2.3 OC3/STM1 to support
release 3.0 and higher. Factory shipments of OC3/STM1 R2.3 and higher cards,
90-2188-2X/3X and 90-2305-2X/3X, ship with the memory module 2 installed and
do not require this upgrade kit. NOTE: Cards using 3x PCB's use the
90-4906-02 kit; See 90-4906-02 description for information on PCB
identification. The kit contains a memory module 2 (8 Megabytes), part number
labels, and instructions for installation. |
REQUEST QUOTE |
| 90-4906-02 |
This kit is used to upgrade a R1.3, R2.1,R2.2, or R2.3 OC3/STM1
to support release 3.0 and higher. NOTE: This kit is for cards on a 3x PCB
platform only. All other cards must use the 90-4906-01 kit. Factory shipments
of OC3/STM1 R2.3 and higher cards, 90-2188-2X/3X and 90-2305-2X/3X, ship with
the memory module 2 installed and do not require this upgrade kit. The 3x
platform may be identified by: a) Labelling on the pcb, e.g 87-0807-01-3x. b)
The front panel 90# label; the following manufacturing codes identify cards
using the 3x platform: 90-2188 & 2305-01 - Codes T, U and V 90-2188 &
2305-02 - Codes T, U and V 90-2188 & 2305-03 - Codes P, R, and T 90-2188
& 2305-04 - Codes P, R and T 90-2188
<(><<)>(>&<(><<)>)> 2305-11 - Codes
A, B, C, D, and E 90-2188 & 2305-12 - Codes A, B, C, D, and E 90-2188
& 2305-13 - Codes A, B, C, D, and E 90-2188 & 2305-14 - Codes A, B,
C, and D. |
REQUEST QUOTE |
| 90-4907-01 |
The R3.1 Peripheral Shelf Cardfile is a 19 rackmount shelf which
has 12 universal card slots (UCS) and 2 common equipment card slots (X and
Y). The X (and Y if redundant fabric is required) common equipment card slot
is equipped with a Dual Hub or SHUB Card. The 12 UCSs are equipped with 0, 1,
or 2 Control Cards and up to 10, 11, or 12 interface cards depending on the
number of Control Cards installed. One Control Card is installed for
non-redundant control, two for control redundancy, and zero if Control Cards
have already been installed in another Peripheral Shelf of the 36170 system.
A 36170 system can be equipped with up to 8 Peripheral Shelf Cardfiles for a
total of 96 UCS's. This high power peripheral shelf increases the power
handling capacity to allow for higher-powered cards in future releases of the
36170. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-4908-11 |
This card provides a single FR High Speed Serial Interface which
can operate at speed up to 44.21Mhz. The card can be configured as either DCE
or DTE and is delivered with R4.2 software. |
REQUEST QUOTE |
| 90-4908-21 |
This card provides a single FR High Speed Serial Interface which
can operate at speed up to 44.21Mhz. The card can be configured as either DCE
or DTE. A software license must be ordered with this card. |
REQUEST QUOTE |
| 90-4908-M1 |
This item grants the user a license to use the Release 6.0
software for a HSSI FR 1-PORT card. Note that this does not include the right
to upgrade to R6.0; separate upgrade fees apply. |
|
| 90-4909-1A |
The STM1-2M IR UNI/NNI Card with CPU-2 is both a UNI and NNI
STM1 ATM interface card operating at the SONET STM1 rate of 155 Mbps, with
32k cell buffering per card. The Intermediate Reach (IR) single mode fiber
optical interface has a total loss budget of 12 db. The STM1-2M IR is a
single port card compliant to the requirements of the ATM Forum UNI
Specification (Version 3.1) and the ATM Forum B-ICI Specification (Version
2.0). This card is designed to accept the optional Multi-Service Traffic
Shaping Module (MSTM, 90-4724-01) or enhanced Traffic Shaping Module (eTM,
90-7695-01) which, when installed, provides enhanced traffic management
features. This card variant is shipped with R4.3 S/W. |
REQUEST QUOTE |
| 90-4909-1B |
The STM1-2M LR UNI/NNI Card with CPU-2 is both a UNI and NNI
STM1 ATM interface card operating at the SONET STM1 rate of 155 Mbps, with
32k cell buffering per card. The Long Reach (LR) single mode fiber optical
interface has a total loss budget of 28 db. The STM1-2M LR is single port
card compliant to the requirements of the ATM Forum UNI Specification
(Version 3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card
is designed to accept the optional Multi-Service Traffic Shaping Module (MTSM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which when
installed, provides enhanced traffic management features. This card variant
is shipped with R4.3 S/W. |
REQUEST QUOTE |
| 90-4909-1C |
The STM1-2M MMF Card with CPU-2 is a local ATM (LATM) STM1
interface card operating at the SDH STM1 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF) optional interface has a
typical range of 2km. The STM1-2M MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification (Version
3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card is
designed to accept the optional Multi-Service Traffic Module (MSTM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enchanced traffic management features. This card variant
is shipped with R4.3 S/W. |
REQUEST QUOTE |
| 90-4909-20 |
The STM1-2 XLR UNI/NNI Card with CPU-2 is a both UNI and NNI
STM1 ATM interface card operating at the SONET STM1 rate of 155 Mbps, with
32k cell buffering per card. The transmit and receive wavelength of the XLR
card is 1550 nm and supports up to 110 Km of fiber. The STM1-2 32K XLR is a
single port card compliant to the requirements of the ATM Forum UNI
Specification (Version 3.1) and the ATM Forum B-ICI Specification (Version
2.0). Requires a minimum of Release 3.1 for operational support. This card is
designed to accept the optional Multi-Service Traffic Shaping Module (MTSM,
90-4724-01) which, when installed, provides enhanced traffic management
features. This card variant is shipped R4.2 S/W. |
REQUEST QUOTE |
| 90-4909-29 |
The STM1-2 Electrical Interface Card with CPU-2 is both a UNI
and NNI STM1 ATM interface card operating at the SDH STM1 rate of 155 Mbps,
with 32k cell buffering per card. The electrical interface is dual coaxial
BNC connectors. The line code is code mark inversion (CMI). The STM1-2
Electrical Interface is a single port card compliant to the requirements of
the ATM Forum UNI Specifications (Version 3.1) and the ATM Forum B-ICI
Specifications (Version 2.0). Requires a minimum of Release 3.1 for operational
support. This card is designed to accept the optional Multi-Service Traffic
Shaping Module (MTSM, 90-4724-01) which, when installed, provides enhanced
traffic management features. Each STM1-2 Electrical Interface is shipped with
a MAU 2 Coax Adapter (90-2322-x1). This card variant is shipped with R4.3
S/W. |
REQUEST QUOTE |
| 90-4909-2A |
The STM1-2M IR UNI/NNI Card with CPU-2 is both a UNI and NNI
STM1 ATM interface card operating at the SONET STM1 rate of 155 Mbps, with
32k cell buffering per card. The Intermediate Reach (IR) single mode fiber
optical interface has a total loss budget of 12 db. The STM1-2M IR is a
single port card compliant to the requirements of the ATM Forum UNI
Specification (Version 3.1) and the ATM Forum B-ICI Specification (Version
2.0). This card is designed to accept the optional Multi-Service Traffic
Shaping Module (MSTM, 90-4724-01) or enhanced Traffic Shaping Module (eTM,
90-7695-01) which, when installed, provides enhanced traffic management
features. This card variant is shipped with R5.0 S/W. This card is also
supported on R2.0 of the 7670 ESE. Note that only the eTM is supported for
traffic shaping on the ESE. |
REQUEST QUOTE |
| 90-4909-2B |
The STM1-2M LR UNI/NNI Card with CPU-2 is both a UNI and NNI
STM1 ATM interface card operating at the SONET STM1 rate of 155 Mbps, with
32k cell buffering per card. The Long Reach (LR) single mode fiber optical
interface has a total loss budget of 28 db. The STM1-2M LR is single port
card compliant to the requirements of the ATM Forum UNI Specification
(Version 3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card
is designed to accept the optional Multi-Service Traffic Shaping Module (MTSM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which when
installed, provides enhanced traffic management features. This card variant
is shipped with R5.0 S/W. This card is also supported on R2.0 7670 ESE. On
the ESE shelf only the eTM is supported for traffic shaping. |
REQUEST QUOTE |
| 90-4909-2C |
The STM1-2M MMF Card with CPU-2 is a local ATM (LATM) STM1
interface card operating at the SDH STM1 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF) optional interface has a
typical range of 2km. The STM1-2M MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification (Version
3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card is
designed to accept the optional Multi-Service Traffic Module (MSTM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enchanced traffic management features. This card variant
is shipped with R5.0 S/W. This card is also supported on R2.0 of the 7670
ESE. Note that only the eTM is supported for traffic shaping on the ESE. |
REQUEST QUOTE |
| 90-4909-39 |
The R5.0 STM1-2 Electrical Interface Card with CPU-2 is both a
UNI and NNI STM1 ATM interface card operating at the SDH STM1 rate of 155
Mbps, with 32k cell buffering per card. The electrical interface is dual
coaxial BNC connectors. The line code is code mark inversion (CMI). The
STM1-2 Electrical Interface is a single port card compliant to the
requirements of the ATM Forum UNI Specifications (Version 3.1) and the ATM
Forum B-ICI Specifications (Version 2.0). Requires a minimum of R elease 3.1
for operational support. This card is designed to accept the optional
Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced Traffic
Shaping Module (eTM, 90-7695-01) which, when installed, provides enhanced
traffic management features. This card requires MAU 90-2322-01 for deployment
in 7470 PS-2 shelf or MAU 90-8180-01 for deployment in 7670 ESE shelf. The
90-2322-01 and 90-8180-01 MAUs are not shipped with the STM1-2 card and each
must be ordered separately. The STM1-2 Electrical Interface card with CPU- |
REQUEST QUOTE |
| 90-4909-3A |
The STM1-2M IR UNI/NNI Card with CPU-2 is both a UNI and NNI
STM1 ATM interface card operating at the SONET STM1 rate of 155 Mbps, with
32k cell buffering per card. The Intermediate Reach (IR) single mode fiber
optical interface has a total loss budget of 12 db. The STM1-2M IR is a
single port card compliant to the requirements of the ATM Forum UNI
Specification (Version 3.1) and the ATM Forum B-ICI Specification (Version
2.0). This card is designed to accept the optional Multi-Service Traffic
Shaping Module (MSTM, 90-4724-01) or enhanced Traffic Shaping Module (eTM,
90-7695-01) which, when installed, provides enhanced traffic management
features. This card is also supported on R2.0 of the 7670 ESE. Note that only
the eTM is supported for traffic shaping on the ESE. |
REQUEST QUOTE |
| 90-4909-3B |
The STM1-2M LR UNI/NNI Card with CPU-2 is both a UNI and NNI
STM1 ATM interface card operating at the SONET STM1 rate of 155 Mbps, with
32k cell buffering per card. The Long Reach (LR) single mode fiber optical
interface has a total loss budget of 28 db. The STM1-2M LR is single port
card compliant to the requirements of the ATM Forum UNI Specification
(Version 3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card
is designed to accept the optional Multi-Service Traffic Shaping Module (MTSM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which when
installed, provides enhanced traffic management features. This card is also
supported on R2.0 7670 ESE. On the ESE shelf only the eTM is supported for
traffic shaping. |
REQUEST QUOTE |
| 90-4909-3C |
The STM1-2M MMF Card with CPU-2 is a local ATM (LATM) STM1
interface card operating at the SDH STM1 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF) optional interface has a
typical range of 2km. The STM1-2M MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification (Version
3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card is
designed to accept the optional Multi-Service Traffic Module (MSTM,
90-4724-01) or enhanced Traffic Shaping Module (eTM, 90-7695-01) which, when
installed, provides enchanced traffic management features. This card is also
supported on R2.0 of the 7670 ESE. Note that only the eTM is supported for
traffic shaping on the ESE. |
REQUEST QUOTE |
| 90-4909-48 |
The STM1-2M MMF Card with CPU-2 is a local ATM (LATM) STM1
interface card operating at the SDH STM1 rate of 155 Mbps, with 32k cell
buffering per card. The multi-mode fiber (MMF) optional interface has a
typical range of 2km. The STM1-2M MMF Card is a single port card and is
compliant to the requirements of the ATM Forum UNI Specification(Version 3.1)
and the ATM Forum B-ICI Specification(Version 2.0). Requires a minimum of
Release 4.2 for operational support. This card is designed to accept the
optional Multi-Service Traffic Module (MSTM, 90-4724-01) or enhanced Traffic
Shaping Module (eTM,90-7695-01) which, when installed, provides enchanced
traffic management features. This card variant is shipped with R5.0 software.
Note that only the eTM is supported for traffic shaping on the ESE. MD
EFFECTIVITY DATE = AUGUST 1, 2004 AS PER PDN 9199. |
REQUEST QUOTE |
| 90-4909-49 |
The R5.0 STM1-2 Electrical Interface Card with CPU-2 is both a
UNI and NNI STM1 ATM interface card operating at the SDH STM1 rate of 155
Mbps, with 32k cell buffering per card. The electrical interface is dual
coaxial BNC connectors. The line code is code mark inversion (CMI). The
STM1-2 Electrical Interface is a single port card compliant to the
requirements of the ATM Forum UNI Specifications (Version 3.1) and the ATM
Forum B-ICI Specifications (Version 2.0). Requires a minimum of R elease 3.1
for operational support. This card is designed to accept the optional
Multi-Service Traffic Shaping Module (MTSM, 90-4724-01) or enhanced Traffic
Shaping Module (eTM, 90-7695-01) which, when installed, provides enhanced
traffic management features. This card requires MAU 90-2322-01 for deployment
in 7470 PS-2 shelf or MAU 90-8180-01 for deployment in 7670 ESE shelf. The
90-2322-01 and 90-8180-01 MAUs are not shipped with the STM1-2 card and each
must be ordered separately. |
REQUEST QUOTE |
| 90-4918-01 |
This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4919-01 |
The DS3/E3 Switching MAU provides two pairs of coaxial
connectors for all single port DS3 or E3 interface cards. One pair connects
to the Tx and Rx of the primary card and the other is used to route to a
sparing card via the sparing control panel (90-4918-01). This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-4920-01 |
0 |
REQUEST QUOTE |
| 90-4921-01 |
0 |
REQUEST QUOTE |
| 90-4922-01 |
This cable connects from a DS3/E3 card to a Switching MAU
(90-4919-01 - Ordered separately). The cable allows a card to control the
switching MAU on an adjacent card, providing a 1:1 sparing capability. |
REQUEST QUOTE |
| 90-4927-01 |
The 28LC is a 6 Port RADSL Line Card used to connect the 2801-2W
(90-4925-01) and 2801-4W (90-4826-01) Data Termination Units. It supports
enhanced operation administration and maintenance features such as open short
detection, line quality statistics and power failure detection for the
2801-2W and 2801-4W. This is the Class A Compliant version of the 28LC. |
REQUEST QUOTE |
| 90-4963-01 |
This assembly is a replacement Integrated Cooling Unit for the
36170 Switching Shelf (90-2181-01), Peripheral Shelf -1 (90-2190-01) and High
Speed Peripheral Shelf (90-2291-01). It contains two fan assemblies and an
alarm/power distribution assembly in an integrated package. |
REQUEST QUOTE |
| 90-5037-07 |
This is a UCS card that provides switched services and call
processing functions for the switch. It is required for systems that support
SVCs and/or S-PVCs, and should not be used in systems which employ an
Integrated Control card. This card is delivered with R4.3 software and an
enhanced Processor Module (ePM). This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-5037-08 |
This is a UCS card that transfers statistics and accounting data
to an external Data Collector, for billing or bulk statistics accumulation.
Comes with DB-25 to RJ-34 Ethernet 10Base-T MAU. This card is delivered with
R4.3 software and with an enhanced Processor Module (ePM). |
REQUEST QUOTE |
| 90-5037-09 |
This is a UCS card that provides switched services PNNI dynamic
routing. This card, or an Integrated CallP/PNNI Card-2 (but not both) are
required for systems that use PNNI Routing. This card is delivered with R4.3
software and with an enhanced Processor Module (ePM). This assembly contains
a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-5037-17 |
This is a UCS card that provides switched services and call
processing functions for the switch. It is required for systems that support
SVCs and/or S-PVCs, and should not be used in systems which employ an
Integrated Control card. This card is delivered with R5.0 software and an
enhanced Processor Module (ePM). |
REQUEST QUOTE |
| 90-5037-18 |
This is a UCS card that transfers statistics and accounting data
to an external Data Collector or Statistics Collector, for billing or bulk
statistics accumulation. Comes with DB-25 to RJ-34 Ethernet 10Base-T MAU.
This card is delivered with R5.0 software and with an enhanced Processor
Module(ePM). |
REQUEST QUOTE |
| 90-5037-19 |
This is a UCS card that provides switched services PNNI dynamic
routing. This card, or an Integrated CallP/PNNI Card-2 (but not both) are
required for systems that use PNNI Routing. This card is delivered with R5.0
software and with an enhanced Processor Module (ePM). |
REQUEST QUOTE |
| 90-5037-41 |
This is a UCS card that provides switched services, call
processing, and routing. This card, an Integrated CallP/PNNI Card-2 is
required for systems that support SVC and/or S-PVC calls. This card is
delivered with R4.3 software. |
REQUEST QUOTE |
| 90-5037-42 |
This is a UCS card that transfers statistics and accounting data
on an external Data Collector, for billing or bulk statistics accumulation.
Comes with DB-25 to RJ-34 Ethernet 10Base-T MAU. This card is delivered with
R4.3 software. |
REQUEST QUOTE |
| 90-5037-43 |
This is a UCS card that provides switched services PNNI dynamic
routing. THis card or an Integrated CallP/PNNI Card-2 are required for
systems that use PNNI Routing. This card is delivered with R4.3 software. |
REQUEST QUOTE |
| 90-5060-01 |
This is a package of 20 replacement air filters for the 36170
Peripheral Shelf -1 (90-2190-01), the Switching Shelf (90-2181-01) and the
High Speed Peripheral Shelf (90-2291-01). |
REQUEST QUOTE |
| 90-5838-03 |
Provides AAL1 and AAL5 service adaptation, Cell Multiplexing
(UNI 3.1) and n x E1 (n=1, 2, 3 or 4) aggregate trunks. Also provides ATM
Inverse Multiplexing (IMA). A front cover (90-3647-01) is required when this
card is used in Class B or EU applications. |
REQUEST QUOTE |
| 90-5891-03 |
The 7470 1.6G Dual Hub Card 2 is common equipment card for the
Peripheral Shelf Cardfile. The Dual Hub card handles two bi-directional 800M
ISL links: ISL Port#1 supports UCS 1-6 and ISL Port#2 supports UCS 7-12. Two
Dual Hub Cards are required perperipheral shelf (for fabric redundancy) in
multi-shelf systems. The 1.6G Dual Hub 2 is delivered with R4.2 software.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-5891-12 |
The Extended ISL (X-ISL) Dual Hub card provides two
bi-directional 800M ISL links supporting 12 UCS slots in a peripheral shelf.
ISL Port#1 supports UCS slots 1-6, and ISL Port#2 supports UCS slots 7-12.
Two X-ISL Dual Hub Cards are required per peripheral shelf for fabric
redundancy in multi-shelf systems. This card is delivered with R4.2
application software. X-ISL reach is 15km over computer supplied Single Mode
Fiber. SMF cable requirements are: 9/125 micron core/cladding, 0.35 dB/Km
attenuation at 1310nm, flat polish SC/SC connectors. |
REQUEST QUOTE |
| 90-5891-13 |
The 7470 1.6G Dual Hub Card 2 is common equipment card for the
Peripheral Shelf Cardfile. The Dual Hub card handles two bi-directional 800M
ISL links: ISL Port#1 supports UCS 1-6 and ISL Port#2 supports UCS 7-12. Two
Dual Hub Cards are required perperipheral shelf (for fabric redundancy) in
multi-shelf systems. |
REQUEST QUOTE |
| 90-5930-01 |
The E1 120 PRI RJ45 Distribution Panel provides 8 external RJ45
interfaces to the 120 ohm E1 twisted pair ports of a PRI CE card. It may only
be used with PRI CE cards 90-2517-X2. The panel is a 1 ver tical unit (VU)
high rack mountable device. |
REQUEST QUOTE |
| 90-5935-13 |
The R5.0 DS3-2 ATM Card w/CPU-2 is a triple port card. Each port
is both a UNI and NNI DS3 ATM interface operating at 45Mbps. Each interface
has dual coax BNC connectors with a range of 450 feet. The DS3-2 card is
fully compliant to the mandatory requirements of the ATM Forum UNI
specification (version 3.1). This DS3 card provides 4.5K connections per
port, larger buffers, more service categories, substantially higher call
processing capabilities and a Traffic Shaping Module position for support of
the optional enhanced traffic management features. The Multi-Service Traffic
Shaping Module (MTSM) can be ordered as 90-4724-01. The enhanced Traffic
Management (eTM) module can be ordered as 90-7695-01. This card requires MAU
90-2322-02 for deployment in 7470 PS-2 shelf or MAU 90-7308-01 for deployment
in 7670 ESE shelf. The 90-2322-01 and 90-7308-01 MAUs are not shipped with
the DS3-2 card and each must be ordered separately. The R5.0 DS3-2 card can
be used in a R2.0 7670 ESE node. |
REQUEST QUOTE |
| 90-5935-22 |
The R4.3 DS3-2 ATM Card w/CPU-2 is a triple port card. Each port
is both a UNI and NNI DS3 ATM interface operating at 45Mbps. Each interface
has dual coax BNC connectors with a range of 450 feet. The DS3-2 card is
fully compliant to the mandatory requirements of the ATM Forum UNI
specification (version 3.1) and the ATM Forum B-ICI specification (version
2.0). The DS3-2 differs from the DS3 card (90-2189-xx) in that it provides
larger buffers, more service categories, substantially higher call processing
capabilties and a Multi-Service Traffic Shaping Module position for support
of the optional enhanced traffic management features a BNC MAU (90-2322-02)
is included for physical connection via coaxial cable. The Multi-Service
Traffic Shaping Module (MTSM) can be ordered as 90-4724-01. The enchanced
Traffic Management (eTM) module can be ordered as 90-7695-01. |
REQUEST QUOTE |
| 90-5935-23 |
DS3-2 ATM Card w/CPU-2 is a triple port card. Each port is both
a UNI and NNI DS3 ATM interface operating at 45Mbps. Each interface has dual
coax BNC connectors with a range of 450 feet. The DS3-2 card is fully
compliant to the mandatory requirements of the ATM Forum UNI specification
(version 3.1). This DS3 card provides 4.5K connections per port, larger
buffers, more service categories, substantially higher call processing
capabilities and a Traffic Shaping Module position for support of the
optional enhanced traffic management features. The Multi-Service Traffic
Shaping Module (MTSM) can be ordered as 90-4724-01. The enhanced Traffic
Management (eTM) module can be ordered as 90-7695-01. This card requires MAU
90-2322-02 for deployment in 7470 PS-2 shelf or MAU 90-7308-02 for deployment
in 7670 ESE shelf. The 90-2322-01 and 90-7308-02 MAUs are not shipped with
the DS3-2 card and each must be ordered separately. |
REQUEST QUOTE |
| 90-5935-24 |
The DS3-2 ATM Card w/CPU-2 is a triple port card. Each port is
both a UNI and NNI DS3 ATM interface operating at 45Mbps. Each interface has
dual coax BNC connectors with a range of 450 feet. The DS3-2 card is fully
compliant to the mandatory requirements of the ATM Forum UNI specification
(version 3.1). This DS3 card provides 4.5K connections per port, larger
buffers, more service categories, substantially higher call processing
capabilities and a Traffic Shaping Module position for support of the optional
enhanced traffic management features. The Multi- Service Traffic Shaping
Module (MTSM) can be ordered as 90-4724-01. The enhanced Traffic Management
(eTM) module can be ordered as 90-7695-01. This card requires MAU 90-2322-02
for deployment in 7470 PS-2 shelf or MAU 90-7308-02 for deployment in 7670
ESE shelf. The 90-2322-01 and 90-7308-02 MAUs are not shipped with the DS3-2
card and each must be ordered separately. The DS3-2 card can be used in a
R2.0 7670 ESE node. This card ships with R5.0 S/W. |
REQUEST QUOTE |
| 90-5935-34 |
The DS3-2 ATM Card w/CPU-2 is a triple port card. Each port is
both a UNI and NNI DS3 ATM interface operating at 45Mbps. Each interface has
dual coax BNC connectors with a range of 450 feet. The DS3-2 card is fully
compliant to the mandatory requirements of the ATM Forum UNI specification
(version 3.1). This DS3 card provides 4.5K connections per port, larger
buffers, more service categories, substantially higher call processing
capabilities and a Traffic Shaping Module position for support of the optional
enhanced traffic management features. The Multi- Service Traffic Shaping
Module (MTSM) can be ordered as 90-4724-01. The enhanced Traffic Management
(eTM) module can be ordered as 90-7695-01. This card requires MAU 90-2322-02
for deployment in 7470 PS-2 shelf or MAU 90-7308-02 for deployment in 7670
ESE shelf. The 90-2322-01 and 90-7308-02 MAUs are not shipped with the DS3-2
card and each must be ordered separately. The DS3-2 card can be used in a
R2.2 (or higher) 7670 ESE node. |
REQUEST QUOTE |
| 90-5946-01 |
The Ring Generator PSU is intended for use with the External
Ring Generator assembly (90-5945-01), and 3600 system power trays
(90-3669-xx). The Ring Generator PSU includes one ringing power supply unit
(PSU) and grounding wire. There are some switches on the product to select;
DC bias, and operation frequency (16Hz, 20Hz, or 25Hz). The External Ring
Generator configuration requirements: dual output, redundant operation = 4
Ring Generator PSU; single output, redundant operation = 2 Ring Generator
PSU; dual output, non-redundant operation = 2 Ring Generator PSU. |
REQUEST QUOTE |
| 90-5947-13 |
The R5.0 E3-2 ATM Card w/CPU-2 is a triple port card. Each port
is both a UNI or NNI E3 ATM interface operating at 45Mbps. Each interface has
dual coax BNC connectors with a range of 450 feet. The E3-2 card is fully
compliant to the mandatory requirements of the ATM Forum UNI
specification(version 3.1). This E3 card provides 4.5K connections per port,
larger buffers, more service categories, substantially higher call processing
capabilities and a Traffic Shaping Module position for support of the optional
enhaned traffic management features. The Multi-Service Traffic Shaping
Module(MTSM) can be ordered as 90-4724-01. The enhanced Traffic Management
(eTM) module can be ordered as 90-7695-01. This card requires MAU 90-2322-02
for deployment in 7470 PS-2 shelf or MAU 90-7308-02 for deployment in 7670
ESE shelf. The 90-2322-01 and 90-7308-02 MAUs are not shipped with the E3-2
card and each must be ordered separately. The R5.0 E3-2 card can be used in a
R2.0 7670 ESE node. |
REQUEST QUOTE |
| 90-5947-22 |
The R4.3 E3-2 ATM Card w/CPU-2 is a triple port card. Each port
is both a UNI and NNI E3 ATM interface operating at 34Mbps. Each interface is
dual coax BNC connectors with a range of 450 feet. The E3-2 card is fully
compliant to the mandatory requirements of the ATM Forum UNI specification
(version 3.1) and the ATM Forum B-ICI specification (version 2.0). The E3-2
differs from the E3 card (90-2294-xx) in that it provides larger buffers,
more service categories, substantially higher call processing capabilities
and a Multi-Service Traffic Shaping Module position for support of the
optional enhanced traffic management features. A BNC MAU (90-2322-02) is
included for physical connection via coaxial cable. The Multi-Service Traffic
shaping module (MTSM) can be ordered as 90-4724-01. |
REQUEST QUOTE |
| 90-5947-23 |
E3-2 ATM Card w/CPU-2 is a triple port card. Each port is both a
UNI or NNI E3 ATM interface operating at 45Mbps. Each interface has dual coax
BNC connectors with a range of 450 feet. The E3-2 card is fully compliant to
the mandatory requirements of the ATM Forum UNI specification(version 3.1).
This E3 card provides 4.5K connections per port, larger buffers, more service
categories, substantially higher call processing capabilities and a Traffic
Shaping Module position for support of the optional enhaned traffic
management features. The Multi-Service Traffic Shaping Module(MTSM) can be
ordered as 90-4724-01. The enhanced Traffic Management (eTM) module can be
ordered as 90-7695-01. This card requires MAU 90-2322-02 for deployment in
7470 PS-2 shelf or MAU 90-7308-02 for deployment in 7670 ESE shelf. The
90-2322-01 and 90-7308-02 MAUs are not shipped with the E3-2 card and each
must be ordered separately. The E3-2 card can be used in a R2.2 (or higher)
7670 ESE node. MD EFFECTIVITY DATE = AUGUST 31, 2003 AS PER PDN 9200 |
REQUEST QUOTE |
| 90-5947-24 |
The E3-2 ATM Card w/CPU-2 is a triple port card. Each port is
both a UNI or NNI E3 ATM interface operating at 45Mbps. Each interface has
dual coax BNC connectors with a range of 450 feet. The E3-2 card is fully
compliant to the mandatory requirements of the ATM Forum UNI
specification(version 3.1). This E3 card provides 4.5K connections per port,
larger buffers, more service categories, substantially higher call processing
capabilities and a Traffic Shaping Module position for support of the
optional enhaned traffic management features. The Multi-Service Traffic
Shaping Module(MTSM) can be ordered as 90-4724-01. The enhanced Traffic
Management (eTM) module can be ordered as 90-7695-01. This card requires MAU
90-2322-02 for deployment in 7470 PS-2 shelf or MAU 90-7308-02 for deployment
in 7670 ESE shelf. The 90-2322-01 and 90-7308-02 MAUs are not shipped with
the E3-2 card and each must be ordered separately. The E3-2 card can be used
in a R2.0 7670 ESE node. This card ships with R5.0 S/W. This card is also
supported on R2.0 7670 ESE. On the ESE shelf only the eTM is supported for
traffic shaping. |
REQUEST QUOTE |
| 90-5947-34 |
The E3-2 ATM Card w/CPU-2 is a triple port card. Each port is
both a UNI or NNI E3 ATM interface operating at 45Mbps. Each interface has
dual coax BNC connectors with a range of 450 feet. The E3-2 card is fully
compliant to the mandatory requirements of the ATM Forum UNI
specification(version 3.1). This E3 card provides 4.5K connections per port,
larger buffers, more service categories, substantially higher call processing
capabilities and a Traffic Shaping Module position for support of the
optional enhaned traffic management features. The Multi-Service Traffic
Shaping Module(MTSM) can be ordered as 90-4724-01. The enhanced Traffic
Management (eTM) module can be ordered as 90-7695-01. This card requires MAU
90-2322-02 for deployment in 7470 PS-2 shelf or MAU 90-7308-02 for deployment
in 7670 ESE shelf. The 90-2322-01 and 90-7308-02 MAUs are not shipped with
the E3-2 card and each must be ordered separately. The E3-2 card can be used
in a R2.0 7670 ESE node. |
REQUEST QUOTE |
| 90-6014-01 |
This part contains the Up and Down ISL cabling required to
interconnect a Low Speed Peripheral Shelf to the Switching Shelf. This part
number is a multi-mode 3 meter single fiber cable with staggered ends. The
part includes two ISL cables, where each ISL cable consists of an 800 Mb/s
strand to create an Up or Down ISL. |
REQUEST QUOTE |
| 90-6014-02 |
This part contains the Up and Down ISL cabling required to
interconnect a Low Speed Peripheral Shelf to the Switching Shelf. This part
number is a multi-mode 10 meter single fiber cable with staggered ends. The
part includes two ISL cables, where each ISL cable consists of an 800 Mb/s
strand to create an Up or Down ISL. |
REQUEST QUOTE |
| 90-6014-03 |
This part contains the Up and Down ISL cabling required to
interconnect a Low Speed Peripheral Shelf to the Switching Shelf. This part
number is a multi-mode 6 meter single fiber cable with staggered ends. The
part includes two ISL cables, where each ISL cable consists of an 800 Mb/s
strand to create an Up or Down ISL. |
REQUEST QUOTE |
| 90-6018-43 |
CD-ROM for 7470 Release
4.3 containing Hardened Load Set#1. |
REQUEST QUOTE |
| 90-6018-50 |
CD-ROM for 7470 Release
5.0 containing Hardened Load Set#1. |
REQUEST QUOTE |
| 90-6018-60 |
CD-ROM for 7470 Release
6.0. |
REQUEST QUOTE |
| 90-6032-01 |
The DCE HSSI MAU provides DCE signalling to a HSSI Frame Relay
card (90-4908-01). This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6032-02 |
The DTE HSSI MAU provides DTE signalling to a HSSI Frame Relay
card (90-4908-01). This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6052-01 |
Intended for use with the 3600/3600+ MainStreet External Ring
Generator Assy (90-5945-01). This cable kit connects the ringing voltage
output to 3600 or 3600+ systems. Includes three cables: one for each 3600
shelf (90-0010-10, or 90-0010-13, or 90-0010-14) and 3600+ system
(90-2671-02). This kit is required for redundant ringing generator operation. |
REQUEST QUOTE |
| 90-6085-11 |
The Single Shelf Hub Card-2 is the common equipment card for the
peripheral Shelf Card File which has local switching capability, supporting
the advanced traffic management capabilities introduced in Release 3.1. This
card configures the Peripheral Shelf to be a 1.6 Gb Stand alone switch. Two
Single Shelf Hub Card-2's are required per peripheral shelf (for fabric
redundancy) in multi-shelf system. This card is delivered with R4.2
application software. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6085-21 |
The Single Shelf Hub Card-2 is the common equipment card for the
peripheral Shelf Card File which has local switching capability, supporting
the advanced traffic management capabilities introduced in Release 3.1. This
card configures the Peripheral Shelf to be a 1.6 Gb Stand alone switch. Two
Single Shelf Hub Card-2's are required per peripheral shelf (for fabric
redundancy) in multi-shelf system. |
REQUEST QUOTE |
| 90-6184-23 |
This card enables additional IP functionality on existing
interfaces for the 7470 MSP. Release 4.3 of the ISC provides new capabilities
in addition to those supported in R4.2. Dynamic routing using OSPF is
supported 1+1 redundancy of ISCs is supported when installed in adjacent
slots and with the use of a Dual Mau (90-6819-01). This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6184-33 |
This card enables additional IP functionality on existing
interfaces for the 7470 MSP. Release 4.3 of the ISC provides new capabilities
in addition to those supported in R4.2. Dynamic routing using OSPF is
supported. 1+1 redundancy of ISCs is supported when installed in adjacent
slots and with the use of a Dual Mau (90-6819-01). This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6197-21 |
The OC12-2 ATM IR Card is a UNI/NNI OC12 ATM interface card
operating at the SONET OC12 rate of 622 Mbps, with 32k egress cell buffering
per card and advanced traffic management capability. The Intermediate Reach
(IR) single mode fiber optional interface has a total loss budget of 12 db.
The OC12-2 employs the CPU-2 module for enhanced call performance. The OC12-2
requires at least Release 4.2 for operational support. This assembly contains
a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6197-22 |
Identical to the 90-6197-21 except the Long Reach (LR) single
mode fiber optical interface has a total loss budget of 24 db. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6197-23 |
Identical to the 90-6197-21 except the Short Reach (SR) card
utilizes a multi mode fiber optical interface. The SR card has a total loss
budget of 6 db. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6197-24 |
Identical to 90-6197-21 except the Extra Long Reach (XLR) single
mode fiber optical interface has a center wavelength of 1550 nm. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-6197-31 |
The OC12-2 ATM IR Card is a UNI/NNI OC12 ATM interface card
operating at the SONET OC12 rate of 622 Mbps, with 32k egress cell buffering
per card and advanced traffic management capability. The Intermediate
Reach(IR) single mode fiber optional interface has a total loss budget of 12
db. The OC12-2 employs the CPU-2 module for enhanced call performance. The
OC12-2 requires a minimum of release 4.2 for operational support. |
REQUEST QUOTE |
| 90-6197-32 |
Identical to the 90-6197-31 except the Long Reach (LR) single
mode fiber optical interface has a total loss budget of 24 db. |
REQUEST QUOTE |
| 90-6197-33 |
Identical to the 90-6197-31 except the Short Reach (SR) card
utilizes a multi mode fiber optical interface. The SR card has a total loss
budget of 6 db. |
REQUEST QUOTE |
| 90-6197-34 |
Identical to 90-6197-31 except the Extra Long Reach (XLR) single
mode fiber optical interface has a center wavelength of 1550 nm. |
REQUEST QUOTE |
| 90-6197-41 |
The OC12-2 ATM IR Card is a UNI/NNI OC12 ATM interface card
operating at the SONET OC12 rate of 622 Mbps, with 32k egress cell buffering
per card and advanced traffic management capability. The Intermediate
Reach(IR) single mode fiber optional interface has a total loss budget of 12
db. The OC12-2 employs the CPU-2 module for enhanced call performance. |
REQUEST QUOTE |
| 90-6197-42 |
Identical to the 90-6197-31 except the Long Reach (LR) single
mode fiber optical interface has a total loss budget of 24 db. |
REQUEST QUOTE |
| 90-6197-43 |
Identical to the 90-6197-31 except the Short Reach (SR) card
utilizes a multi mode fiber optical interface. The SR card has a total loss
budget of 6 db. |
REQUEST QUOTE |
| 90-6197-44 |
Identical to 90-6197-31 except the Extra Long Reach (XLR) single
mode fiber optical interface has a center wavelength of 1550 nm. |
REQUEST QUOTE |
| 90-6200-21 |
The STM4-2 ATM IR Card is a UNI/NNI STM4 ATM interface card
operating at the SONET STM4 rate of 622 Mbps, with 32k egress cell buffering
management capability. The Intermediate Reach (IR) single mode fiber optical
interface has a total loss budget of 12 db. The STM4-2 employs the CPU-2
module for enhanced call performance. The STM4-2 requires release 4.2 for
operational support. |
REQUEST QUOTE |
| 90-6200-22 |
Identical to 90-6200-21 except the Long Reach (LR) single mode
fiber optical interface has a total loss budget of 24 db. |
REQUEST QUOTE |
| 90-6200-24 |
Identical to 90-6200-21 except the eXtra Long Reach(XLR) single
mode fiber optical interface has a center wavelength of 1550nm. |
REQUEST QUOTE |
| 90-6200-31 |
The STM4-2 ATM IR Card is a UNI/NNI STM4 ATM interface card
operating at the SONET STM4 rate of 622 Mbps, with 32k egress cell buffering
management capability. The Intermediate Reach(IR) single mode fiber optical
interface has a total loss budget of 12 db. The STM4-2 employs the CPU-2
module for enhanced call performance. The STM4-2 requires a minimum of
release 4.2 for operational support. |
REQUEST QUOTE |
| 90-6200-32 |
Identical to 90-6200-21-31 except the Long Reach (LR) single
mode fiber optical interface has a total loss budget of 24 db. |
REQUEST QUOTE |
| 90-6200-34 |
Identical to 90-6200-31 except the eXtra Long Reach(XLR) single
mode fiber optical interface has a center wavelength of 1550nm. |
REQUEST QUOTE |
| 90-6200-41 |
The STM4-2 ATM IR Card is a UNI/NNI STM4 ATM interface card
operating at the SONET STM4 rate of 622 Mbps, with 32k egress cell buffering
management capability. The Intermediate Reach(IR) single mode fiber optical
interface has a total loss budget of 12 db. The STM4-2 employs the CPU-2
module for enhanced call performance. |
REQUEST QUOTE |
| 90-6200-42 |
Identical to 90-6200-21-31 except the Long Reach (LR) single
mode fiber optical interface has a total loss budget of 24 db. |
REQUEST QUOTE |
| 90-6200-44 |
Identical to 90-6200-31 except the eXtra Long Reach(XLR) single
mode fiber optical interface has a center wavelength of 1550nm. |
REQUEST QUOTE |
| 90-6226-07 |
This card provides the functionality of a R4.3 Control Card, a
R4.3 CallP Card-2 and a R4.3 PNNI Card-2, all combined on a single card. One
card is required for non-redundant operation, and two cards for redundancy
per 7470 system. This card must be installed in Control Card slots only, and
cannot be used in systems that have been configured with CallP-2 Cards or
PNNI-2 Routing cards. Node management, alarm, and timing terminations require
a control card interconnect panel (CCIP). One CCIP serves both active and
redundant integrated control cards. There are two variants of CCIP for US
Telco (90-2295-x1) and International (90-2295-x2) requirements. This card is
delivered with R4.3 software, and with an enhanced Processor Module (ePM),
and with a NAND-based 256MB memory card. Note that previous to this note, all
control cards were shipped wih NOR-based memory cards. The software loadset
required for this card is documented in Field Notice FN1867. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6226-09 |
This card provides the functionality of a Control Card-2, a
CallP Card-2, a PNNI Card-2, and a Data Spooling-2 card, all combined on a
single card. Two cards are required for redundancy per 7470 system. This card
must be installed in Control CArd slots only, and cannot be used in systems
that have also been configued with CallP-2 Cards or PNNI-2 Routing cards.
Node management, alarm, and timing terminations required a control card
interconnect panel (CCIP). One CCIP serves both active and redundant integrated
control cards. There are two variants of CCIP for US Telco (90-2295-x1) and
Internatinal (90-2295-x2) requirements. This card is delivered with R4.3 R5.0
software, a larger SanDisk and with an enhanced Processor Module (ePM). |
REQUEST QUOTE |
| 90-6226-17 |
This card provides the functionality of a Control Card, a CallP
Card-2 and a PNNI Card-2, all combined on a single card. Two cardsare
required for redundancy per 7470 system. This card must be installed in
Control Card slots only, and cannot be used in systems that have been
configured with CallP-2 Cards or PNNI-2 Routing cards. Node management,
alarm, and timing terminations require a control card interconnect panel
(CCIP). One CCIP serves both active and redundant integrated control cards.
There are two variants of CCIP for US Telco (90-2295-x1) and International
(90-2295-x2) requirements. This card is delivered with R5.0 software, a
larger SanDisk and with an enhanced Processor Module (ePM). |
REQUEST QUOTE |
| 90-6226-19 |
INTEG CALLP/PNNI/SPOOLING CARD-2 W/EPM |
REQUEST QUOTE |
| 90-6226-27 |
INTEG CALLP/PNNI CARD-2 WITH EPM |
REQUEST QUOTE |
| 90-6226-41 |
This card provides the functionality of a R4.3 Control Card-2, a
R4.3 CallP Cad-2 and a R4.3 PNNI Card-2, all combined on a single card. One
card is required for non-redundant operation, and two cards for redundancy
per 36170 system. This card must be installed in Contron Card slots only, and
cannot be used in systems that have also been configured with CallP-2 Cards
or PNNI-2 Routing cards. Node management, alarm, and timing terminations
required a control card interconnect panel (CCIP). One CCIP serves both
active and redundant integrated control cards. There are two variants of CCIP
for US Telco (90-2295-x1) and International (90-2295-x2) requirements. This
card is delivered with R4.3 software. Note that this card uses the Processor
Module, and that the enhanced Processor Module (ePM) is required to upgrade
to R5.0. Consequently, it is recommended that 90-6226-07 or 90-6226-09 be
used instead of this part. |
REQUEST QUOTE |
| 90-6337-01 |
This is a mid mounting bracket assembly for the 12VU 36170
Peripheral Shelf (90-2190-x1). This is the only shelf to use this assembly.
This package consists of cable management troughs, and 19 - 23 rack adapters. |
REQUEST QUOTE |
| 90-6337-02 |
This is a mid mounting bracket assembly for the 13VU 36170
Shelves. This package is only for use with the Switching Shelf (90-2181-x1),
High Speed Peripheral Shelf (90-2291-x1), and High Power Peripheral Shelf
(90-4907-x1). This package consists of cable management troughs, and 19 - 23
rack adapters. |
REQUEST QUOTE |
| 90-6344-01 |
The E1/T1 PRI APS Shelf consists of a card cage and a backplane
which houses APS Cards that work with the 8-port CE cards. The shelf,
together with the I/F CARD PRI APS (90-6345-02) and CONTROL CARD PRI APS
(90-6346-01) provide N:1 Automatic Protection Switching support for T1/E1 CE
Cards on the 7470 by switching the traffic on a failed card to the protection
card. |
REQUEST QUOTE |
| 90-6345-02 |
The I/F PRI APS Card in combination with CONTROL CARD PRI APS
(90-6346-01) and the E1/T1 PRI APS SHELF (90-6344-01) provides N:1 Automatic
Protection Switching support for T1/E1 CE Cards on the 36170. Each T1/E1 Card
on the 36170 that is to be protected must be connected to an Interface APS
Card in the APS Shelf. The Interface APS Cards contain relays to route the
traffic to either its regular PRI Card, or onto the panels protection bus
where the traffic is routed to the protection card. This APS card is
compatible with the T1/E1 PRI CE MAUs. |
REQUEST QUOTE |
| 90-6346-01 |
The PRI APS Control Card in combination with the I/F CARD PRI
APS (90-6345-02) and E1/T1 PRI APS SHELF (90-6344-01) provides N:1 Automatic
Protection Switching support for T1/E1 CE Cards on the 36170. Each T1/E1 Card
serving as a protection card on the 36170 must be connected to an APS Control
Card in the APS Shelf. The APS Control Card controls the relays on APS
Interface Cards and allows multiple N:1 protection groups to be supported
within the same PRI APS Shelf. |
REQUEST QUOTE |
| 90-6351-21 |
This card utilizes the CPU-2 and provides eight T1 ports for
Cell Relay (ATM) services on the 7470, with 32k cell buffering per card and
advanced traffic management capability. This card allows an optional upgrade
module (90-4672-01) to provide up to four groups of ATM Inverse Multiplexing.
Physical connection via RJ-45, wire-wrap, or standard 50-pin Telco connector
can be supported. RJ-45 connection requires a PRI RJ-45 Distribution Panel
(90-2543-01) and associated 8-port cable (90-2767-xx) for each card.
Wire-wrap connection requires one wire-wrap MAU (90-2542-02) per card and the
50-pin connector requires one Telco MAU (90-2542-01) per card. This card is
shipped with R4.3 software. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6351-22 |
This 120 Ohm card utilizes the CPU-2 and provides eight E1 ports
for Cell Relay (ATM) services on the 7470, with 32k cell buffering per card
and advanced traffic management capability. This card allows an optional
upgrade module (90-4672-01) to provide up to four groups of ATM Inverse
Muliplexing. Physical connection via RJ-45, wire-wrap, or standard 50-pin
Telco connector can be supported. RJ-45 connection rquires a PRI RJ-45
Distribution Panel (90-2543-01) and associated 8-port cable (90-2767-xx) for each
card. Wire-wrap connection requires one wire-wrap MAU (90-2542-02) per card
and the 50-pin connector requires one Telco MAU (90-2542-01) per card. This
card is shipped with R4.3 software. |
REQUEST QUOTE |
| 90-6351-31 |
This card utilizes the CPU-2 and provides eight T1 ports for
Cell Relay(ATM) services on the 7470, with 32k cell buffering per card and
advanced traffic management capability. This card allows an optional upgrade
module(90-4672-01) to provide up to four groups of ATM Inverse Multiplexing.
Physical connection via RJ-45, wire-wrap, or standard 50-pin Telco connector
can be supported. RJ-45 connection requires a PRI RJ-45 Distribution Panel
(90-2543-01) and associated 8-port cable (90-2767-xx)for each card. Wire-wrap
connection requires one wire-wrap MAU (90-2542-02) per card and the 50-pin
connector requires one Telco MAU (90-2542-01)per card. This card is shipped
with R5.0 software. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6351-32 |
This 120 Ohm card utilizes the CPU-2 and provides eight E1 ports
for Cell Relay (ATM) services on the 7470, with 32k cell buffering per card
and advanced traffic management capability. This card allows an optional
upgrade module (90-4672-01)to provide up to four groups of ATM Inverse
Muliplexing. Physical connection via RJ-45, wire-wrap, or standard 50-pin
Telco connector can be supported. RJ-45 connection requires a PRI RJ-45
Distribution Panel (90-2543-01) and associated 8-port cable (90-2767-xx) for each
card. Wire-wrap connection requires one wire-wrap MAU(90-2542-02) per card
and the 50-pin connector requires one Telco MAU (90-2542-01) per card. This
card is shipped with R5.0 software. |
REQUEST QUOTE |
| 90-6351-41 |
This card utilizes the CPU-2 and provides eight T1 ports for
Cell Relay(ATM) services on the 7470, with 32k cell buffering per card and
advanced traffic management capability. This card allows an optional upgrade
module (90-4672-01) to provide up to four groups of ATM Inverse Multiplexing.
Physical connection via RJ-45, wire-wrap, or standard 50-pin Telco connector
can be supported. RJ-45 connection requires a PRI RJ-45 Distribution Panel
(90-2543-01) and associated 8-port cable (90-2767-xx) for each card.
Wire-wrap connection requires one wire-wrap MAU (90-2542-02) per card and the
50-pin connector requires one Telco MAU (90-2542-01)per card. |
REQUEST QUOTE |
| 90-6351-42 |
This 120 Ohm card utilizes the CPU-2 and provides eight E1 ports
for Cell Relay (ATM) services on the 7470, with 32k cell buffering per card
and advanced traffic management capability. This card allows an optional
upgrade module (90-4672-01)to provide up to four groups of ATM Inverse
Muliplexing. Physical connection via RJ-45, wire-wrap, or standard 50-pin
Telco connector can be supported. RJ-45 connection requires a PRI RJ-45
Distribution Panel (90-2543-01) and associated 8-port cable (90-2767-xx) for each
card. Wire-wrap connection requires one wire-wrap MAU(90-2542-02) per card
and the 50-pin connector requires one Telco MAU (90-2542-01) per card. |
REQUEST QUOTE |
| 90-6396-01 |
The 27LC3 line card is used in the 3600 and 3600+ Mainstreet.
This card provides twelve 2B1Q interfaces to 275X Extended Range Data
Termination Units(DTU's). Data Format for each circuit is 2B+D, with an
effective throughput of 144KBPS. This card is for |
REQUEST QUOTE |
| 90-6397-01 |
The DPM3 module is used in the 3600 and 3600+ Mainstreet. The
DPM3 is an optional daughter module that resides on the 27LC3(90-6396-01)
line card. The DPM3 can be used to add Sub Rate Multiplexing capability to
the 27LC3. This feature is particularly use |
REQUEST QUOTE |
| 90-6398-01 |
The Bal/Unbal PRI BNC Distribution Panel provides 8 external BNC
interfaces to the 120 ohm E1 ports of a PRI card. It may be used with any of
the PRI cards (90-4671-x2, 90-2541-x2, 90-2544-x2, 90-2517-x2, 90-6351-x2, or
90-7277-x5). A D.78 cable connects the PRI card to the panel which provides a
BNC connector for each port Tx and one for each port Rx. The panel is 1
vertical unit (VU) high rack-mountable device. Grounding switches allow the
service personnel to independently ground any of the coaxial shields. |
REQUEST QUOTE |
| 90-6417-01 |
Cable to connect T1/E1 APS Panel to 7470 Peripheral shelf UCS
slot. |
REQUEST QUOTE |
| 90-6418-01 |
Cable to connect T1/E1 APS Panel to 8 port AMP Champ Breakout
Panel. |
REQUEST QUOTE |
| 90-6419-01 |
Cable to connect T1/E1 APS Panel to 8 port Dsub78 (the Dsub78 is
the connector) Breakout Panel. |
REQUEST QUOTE |
| 90-6432-01 |
Software key used for maintenance load upgrades that allow
existing DSP5 hardware to be upgraded to the latest HCV, LD-Celp, A-Celp A,
and A-Celp loads contained on the 90-0038-17 and 90-0038-19 DSP5 cards. |
REQUEST QUOTE |
| 90-6432-02 |
Software key used for maintenance load upgrades that allow
existing DSP5 VoFR hardware to be upgraded to the latest VoFR A-Celp A load
contained on the 90-6339-01 and 90-6339-02 DSP5 VoFR cards. |
REQUEST QUOTE |
| 90-6433-01 |
This kit provides circuit card software for the current
maintenance version of the DSP5 Card. Includes CD ROM. |
REQUEST QUOTE |
| 90-6443-01 |
Order this P/N to receive filter replacements for the
90-0890-01,90-0890-02, 90-0890-03, 90-0890-05, and 90-0890-06 fan trays.
Includes a quantity of 20 filters. |
REQUEST QUOTE |
| 90-6464-01 |
This is a distribution panel for the 3600/3600+ Mainstreet ATM
Service Card. The distribution cable comes complete with cable. |
REQUEST QUOTE |
| 90-6465-01 |
This is a distribution panel for the 3600/3600+ Mainstreet ATM
Services Card. The distribution cable comes complete with cable. |
REQUEST QUOTE |
| 90-6499-01 |
The Stratum 3 SSU Module
provides a BITS input clock to the 727 0 system. The Stratum 3 SSU is an
optional module for the Contro l Card (90-4452-0x). This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6502-01 |
V.28 SUBD26M-DB25M DCE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-6502-02 |
V.28 SUBD26M-DB25M DTE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-6502-03 |
V.28 SUBD26M-DB25F DTE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-6502-04 |
V.28 SUBD26M-DB25F DCE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-6534-01 |
Downloadable Memory Module daughter card, includes System
Software for NA, UK and International 3600 Release 8.0 products. Requires
System Control Card (90-0667-01 or 90-0667-04/05/09 mother card. Supports
Software downloading. |
REQUEST QUOTE |
| 90-6535-01 |
Downloadable Memory Module daughter card, includes System
Software for NA, UK and International 3600 Release 8.0 Switching Shelf.
Requires System Control Card (90-0667-01 or 90-0667-04/05/09 mother card.
Supports Software downloading. |
REQUEST QUOTE |
| 90-6536-01 |
Downloadable Memory Module daughter card, includes System
Software for NA, UK and International 3600 Release 8.0 Multi Shelf System
Peripheral Shelf. Requires System Control Card (90-0667-01 or
90-0667-04/05/09 mother card. Supports Software downloading. |
REQUEST QUOTE |
| 90-6539-01 |
This kit provides node software for the current maintenance
version of 36LG Rel 8.0. Includes CD ROM. |
REQUEST QUOTE |
| 90-6540-01 |
Complete customer documentation package for Generic 1118.0 of
the 3600 MainStreet Bandwidth Manager; Generic C118.0 of the 3645 MainStreet
High Speed Bandwidth Manager; Generic Q118.0 of the 3664 MainStreet
Fractional Access Multiplexer, Release 8.0 of the 3600+ Mainstreet High
Capacity Bandwidth Manager; and Release 3 of the 36120 MainStreet Packet
Transfer Exchange in an 8 1/2 x 11 format. |
REQUEST QUOTE |
| 90-6540-02 |
Complete customer documentation package for Generic 1118.0 of
the 3600 Mainstreet Bandwidth Manager; Generic C/D/E/H118.0 of the 3645
Mainstreet High Speed Bandwidth Manager; Generic Q118.0 of the 3664
Mainstreet Fractional Access Multiplexer; Release 8.0 of the 3600+ Mainstreet
High Capacity Bandwidth Manager; and Release 3.0 of the 36120 Mainstreet
Packet Transfer Exchange in a CD ROM format. |
REQUEST QUOTE |
| 90-6541-01 |
3600 Release 8.0 S/W Download Key. |
REQUEST QUOTE |
| 90-6542-01 |
3600 Switching Shelf Release 8.0 S/W Download Key. |
REQUEST QUOTE |
| 90-6543-01 |
3600 3600 Multi Shelf System Peripheral Shelf Unit Release 8.0
S/W Download Key. |
REQUEST QUOTE |
| 90-6544-01 |
3600 E-3 Interface Release 8.0 S/W Download Key. |
REQUEST QUOTE |
| 90-6545-01 |
3600 DS-3 Interface Release 8.0 S/W Download Key. |
REQUEST QUOTE |
| 90-6602-21 |
The 10/100 Mbits/sec Ethernet LAN adaptation card provides
tranparent bridging of Ethernet/IEEE 802.3 LAN traffic over ATM. R4.3
includes several OAM enhancements to the card. This card is delivered with
R4.3 software. This assembly contains a Telcordia CLEI (Common Language
Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6602-31 |
The 10/100 Mbits/sec Ethernet LAN adaptation card provides
tranparent bridging of Ethernet/IEEE 802.3 LAN traffic over ATM. Each port
supports up to 64 IEEE 802.1Q VLANs. This card is delivered with R5.0
software. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-6603-01 |
The twisted pair 10/100 Mbits/sec Ethernet I/O card provides
four 100BaseT ports. This I/O card is used with the 10/100 Mbs Ethernet card
(90-6602-01) card. When used, both 10 Mbs twisted pair and 100 Mbs twisted
pair interfaces are supported, with autonegotiation of the bit rate. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-6743-01 |
This module provides
inverse multiplexing for ATM (IMA) capabil ity for the T1/E1 ATM Cell Relay
interface cards (90-4459-0x) fo r the 7270. This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6744-02 |
The 7270 Multi-Service
Traffic Shaping Module (MTSM) is an opti onal module for the 7270 OC3 STM-1
DS3 and E3 Cell Relay c ards. When installed it provides an additional 200K
cells of b uffering per- VC queuing per VC-shaping ABR Virtual-Source
/Virtual Destination and other traffic management enhancements . |
REQUEST QUOTE |
| 90-6756-01 |
This assembly is a replacement Integrated Cooling Unit for the
36170 Peripheral Shelf - 2 (PS-2 90-4907-01). It contains three fan
assemblies and an alarm/power distribution assembly in an integrated package.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-6757-01 |
The Voiceband Services Card (VSC) terminates TDM channels at its
T1 ports, and provides features including speech compression, silence
removal, and fax demodulation to adapt these TDM channels to transport over
an ATM network. The VSC requires a minimum of one (typical applications
require three) and a maximum of three DSP1 transport modules as per
90-4654-02. Fits 7470. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6757-02 |
The Voiceband Services Card (VSC) terminates TDM channels at its
120 ohm E1 ports, and provides features including speech compression, silence
removal, and fax demodulation to adapt these TDM channels to transport over
an ATM network. The VSC requires a minimum of one (typical applications
require three) and a maximum of three DSP1 transport modules as per
90-4654-02. Fits 7470. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-6757-11 |
The Voiceband Services Card (VSC) terminates TDM channels at its
T1 ports, and provides features including speech compression, silence
removal, and fax demodulation to adapt these TDM channels to transport over
an ATM network. The VSC requires a minimum of one (typical applications
require three) and a maximum of three DSP1 transport modules per 90-4654-01
or 90-4654-02. Fits 7470. |
REQUEST QUOTE |
| 90-6757-12 |
The Voiceband Services Card (VSC) terminates TDM channels at its
120 ohm E1 ports, and provides features including speech compression, silence
removal, and fax demodulation to adapt these TDM channels to transport over
an ATM network. The VSC requires a minimum of one (typical applications
require three) and a maximum of three DSP1 transport modules per 90-4654-01
or 90-4654-02. Fits 7470. |
REQUEST QUOTE |
| 90-6819-01 |
This Dual MAU provides redundancy connectivity between adjacent
pairs of redundant Call Processing cards. This Dual MAU is mandatory if Call
Processing 1+1 hot redundancy is to be used on the Call Processing cards,
available in R4.0 and later. The Dual MAU is not required (for either warm or
hot redundancy) with the Integrated CallP/PNNI system configuration. The IP
Services Card (ISC - 90-6184-xx) uses the same Dual MAU. The Dual MAU is
mandatory to interconnect two adjacent ISC's running in 1+1 Redundancy mode,
available in R4.2 and later. If the MAU is missing, the working card becomes
active and the secondary ISC card is neither active nor providing redundancy. |
REQUEST QUOTE |
| 90-6827-11 |
The DS3 CE card provides the termination of a single DS3 circuit
emulation interface channelized down to DS1. |
REQUEST QUOTE |
| 90-6828-11 |
This card provides High Speed Frame Relay processing. Provides
ATM to FR Service Interworking and Network Interworking. Can also operate in
HDLC frame forwarding mode for transparent transport of HDLC-based protocols
such as X.25, SNA and PPP across the ATM network. Supports Test Access
Connection (TAC) for VBR and Closed Loop Congestion Control. This card is
delivered with R4.3 software. |
REQUEST QUOTE |
| 90-6888-01 |
The programmable serial interface (PSI) I/O card provides 16
ports configurable as V.35, X.21 or V.28/RS-232 physical interfaces. The
physical interface is a 26-pin SCSI D-shell, so appropriate adapter cables
must be used for V.28, V.35 or X.21. Ref 90-6502-01..-04, 90-7004-01..-04,
90-7005-01..-04 |
REQUEST QUOTE |
| 90-6893-01 |
This CD is a 7270 MSC Technical Practices Library that includes
information for all currently available 7270 MSC releases. |
REQUEST QUOTE |
| 90-6894-43 |
Software CD-ROM for 7270 R4.3 containing Hardened Loadset #1.
This is the software license meaning one CD is required for each control card
that needs to be upgraded. |
REQUEST QUOTE |
| 90-6894-50 |
Software CD-ROM for 7270 R5.0 containing Hardened Loadset #1.
This is the software license meaning one CD is required for each control card
that needs to be upgraded. |
REQUEST QUOTE |
| 90-6894-60 |
Software CD-ROM for 7270 R6.0 containing Hardened Loadset #1.
This is the software license meaning one CD is required for each control card
that needs to be upgraded. |
REQUEST QUOTE |
| 90-6925-01 |
This software package supports the Bellcore TR-NWT-001268 ISDN
signaling protocol, allowing N-ISDN to ATM signaling interworking. The
signaling protocol interworking combined with Address Translation/Tunnelling
provide PBX interconnect and VPN support. |
REQUEST QUOTE |
| 90-6925-02 |
This software package supports the ETS 300 102-1 ISDN signaling
protocol, allowing N-ISDN to ATM signaling interworking. The signaling
protocol interworking combined with Address Translation/Tunnelling provide
PBX interconnect and VPN support. |
REQUEST QUOTE |
| 90-6925-03 |
This software package supports the ETS 300 102-1 ISDN signaling
protocol, allowing N-ISDN to ATM signaling interworking. The signaling
protocol interworking combined with Address Translation/Tunnelling provide
PBX interconnect and VPN support. |
REQUEST QUOTE |
| 90-6926-01 |
This software package supports the ETS 300 102-1 ISDN signaling
protocol, allowing N-ISDN to ATM signaling interworking. The signaling
protocol interworking combined with Address Translation/Tunnelling provide
PBX interconnect and VPN support. |
REQUEST QUOTE |
| 90-6926-02 |
This software package supports the Bellcore TR-NWT-001268 ISDN
signaling protocol, allowing N-ISDN to ATM signaling interworking. The
signaling protocol interworking combined with Address Translation/Tunnelling
provide PBX interconnect and VPN support. |
REQUEST QUOTE |
| 90-6926-03 |
This software package supports the Bellcore TR-NWT-001268 ISDN
signaling protocol, allowing N-ISDN to ATM signaling interworking. The
signaling protocol interworking combined with Address Translation/Tunnelling
provide PBX interconnect and VPN support. |
REQUEST QUOTE |
| 90-7004-01 |
X.21 SUBD26M-DB15M DCE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7004-02 |
X.21 SUBD26M-DB15M DTE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7004-03 |
X.21 SUBD26M-DB15F DTE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7004-04 |
X.21 SUBD26M-DB15F DCE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7005-01 |
V.35 SUB26M-M34M DCE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7005-02 |
V.35 SUBD26M-M34M DTE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7005-03 |
V.35 SUBD26M-M34F DTE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7005-04 |
V.35 SUBD26M-M34F DCE CABLE 3M. This cable is for use with the
Programmable Serial Interface I/O card. |
REQUEST QUOTE |
| 90-7020-01 |
This cable is for use with the 3600+ Octal E1(90-3542-0x) The
cable is used to connect two E1 ports in a redundant configuration. |
REQUEST QUOTE |
| 90-7020-02 |
This cable is for use with the 3600+ Octal E1(90-3542-0x) The
cable is used to connect two E1 ports in a redundant configuration. |
REQUEST QUOTE |
| 90-7021-01 |
This cable is for use with the 3600+ Octal T1(90-3541-01). The
cable is used to connect two T1 ports in a redundant configuration. |
REQUEST QUOTE |
| 90-7021-02 |
This cable is for use with the 3600+ Octal T1(90-3541-01). The
cable is used to connect two T1 ports in a redundant configuration. |
REQUEST QUOTE |
| 90-7104-02 |
The multi-fiber (MMF) 100 Mbits/sec Ethernet I/O card provides
four 100 Base-FX ports. This I/O card is used with the 10/100Mbs Ethernet
(90-6602-01) card. When used, only 100 Mbs multi-mode fiber interfaces are
supported. |
REQUEST QUOTE |
| 90-7104-04 |
The single-mode fiber (SMF) 100 Mbits/sec Ethernet I/O card
provides four 100 Base-FX ports. This I/O card is used with the 10/100Mbs
Ethernet (90-6602-01) card. When used, only 100 Mbs single-mode fiber
interfaces are supported. |
REQUEST QUOTE |
| 90-7277-34 |
This card provides sixteen Frame Relay Interface ports that are
DS1 compatible. Each port may be configured for channelized, unchannelized,
or unframed operaton. It can be used with distribution panels 90-2543-01, or
90-8307-01. This card is delivered with R4.3 software. This assembly contains
a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-7277-35 |
This card provides sixteen Frame Relay Interface ports that are
E1 compatible. Each port may be configured for channelized, unchannelized, or
unframed operation. It can be used with distribution panels 90-6398-01,
90-2543-01, or 90-8307-01. This card is delivered with R4.3 software. |
REQUEST QUOTE |
| 90-7277-44 |
This card provides sixteen Frame Relay Interface ports that are
DS1 compatible. Each port may be configured for channelized, unchannelized,
or unframed operaton. It can be used with distribution panels 90-2543-01, or
90-8307-01. This card is delivered with R5.0 software. This assembly contains
a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-7277-45 |
This card provides sixteen Frame Relay Interface ports that are
E1 compatible. Each port may be configured for channelized, unchannelized, or
unframed operation. It can be used with distribution panels 90-6398-01,
90-2543-01, or 90-8307-01. This card is delivered with R5.0 software. |
REQUEST QUOTE |
| 90-7277-54 |
This card provides sixteen Frame Relay Interface ports that are
DS1 compatible. Each port may be configured for channelized, unchannelized,
or unframed operaton. It can be used with distribution panels 90-2543-01, or
90-8307-01. |
REQUEST QUOTE |
| 90-7277-55 |
This card provides sixteen Frame Relay Interface ports that are
E1 compatible. Each port may be configured for channelized, unchannelized or
unframed operation. It can be used with distribution panels 90-6398-01,
90-2543-01, or 90-8307-01. |
REQUEST QUOTE |
| 90-7282-01 |
The DS3 3/1/0 Circuit Emulation Card performs the necessary
operations to allow the transport of individual DSos, N*64k groups of DS0s,
DS1s,or full DS3 circuits through an ATM network. This card supports both
structured and unstructured service as defined by the ATM forum. This card
comes equipped with DS3 MAU (90-2322-02). This assembly contains a Telcordia
CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-7282-02 |
The DS3 3/1/0 Circuit Emulation Card performs the necessary
operations to allow the transport of individual DSos, N*64k groups of DS0s,
DS1s, or full DS3 circuits through an ATM network. This card supports both
structured and unstructured service as defined by the ATM forum. This card
requires MAU 90-2322-02 for deployment in 7470 PS-2 shelf or MAU 90-7308-02
for deployment in 7670 ESE shelf. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-7282-12 |
The DS3 CCE-2 3/1/0 Circuit Emulation card performs the
necessary operations to allow the transport of individual DSos, N*64k groups
of DS0s, DS1s, or full DS3 circuits through an ATM network. This card
supports both structured and unstructured service as defined by the ATM
forum. This card requires MAU 90-2322-02 for deployment in 7470 PS-2 shelf or
MAU 90-7308-02 for deployment in 7670 ESE shelf. |
REQUEST QUOTE |
| 90-7284-01 |
The E3 3/1/0 Circuit Emulation Card performs the necessary
operations to allow the transport of individual 64k time-slots, N*64k groups
of timeslots, E1s, or full E3 circuits through an ATM network. This card
supports both structured and unstructured service as defined by the ATM
forum. |
REQUEST QUOTE |
| 90-7284-02 |
The E3 3/1/0 Circuit Emulation Card performs the necessary
operations to allow the transport of individual 64k time-slots, N*64k groups
of timeslots,E1s,or full E3 circuits through an ATM network. This card
supports both structured and unstructured service as defined by the ATM
forum. This card requires MAU 90-2322-02 for deployment in 7470 PS-2 shelf or
MAU 90-7308-01 for deployment in 7670 ESE shelf. |
REQUEST QUOTE |
| 90-7284-12 |
The E3 3/1/0 Circuit Emulation Card performs the necessary
operations to allow the transport of individual 64k time-slots, N*64k groups
of timeslots,E1s,or full E3 circuits through an ATM network. This card
supports both structured and unstructured service as defined by the ATM
forum. This card requires MAU 90-2322-02 for deployment in 7470 PS-2 shelf or
MAU 90-7308-01 for deployment in 7670 ESE shelf. |
REQUEST QUOTE |
| 90-7285-01 |
The 8-Port CE Echo Cancellation Module is an extension module
for the 7470/7270/7670ESE 120 ohm 8-port T1/E1 CE Cards. The echo
cancellation module monitors ingress and egress speech in order to compute an
estimate of the undesired echo that may be present. This estimate is then
used to cancel echoes which accumulate due to hybrids and other effects in
the voice network. This module provides up to 63 milliseconds of tail length.
This assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-7285-01 |
The 8-Port CE Echo Cancellation Module is an extension module
for the 7470/7270/7670ESE 120 ohm 8-port T1/E1 CE Cards. The echo
cancellation module monitors ingress and egress speech in order to compute an
estimate of the undesired echo that may be present. This estimate is then
used to cancel echoes which accumulate due to hybrids and other effects in
the voice network. This module provides up to 63 milliseconds of tail length.
This assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-7285-02 |
The 8-port CE Echo Cancellation Module is an extension module
for the 120 ohm 7470/7270/7670ESE 8-port T1/E1 CE Cards. The echo
cancellation module monitors ingress and egress speech in order to compute an
estimate of the undesired echo that may be present. This estimate is then
used to cancel echoes which accumulate due to hybrids and other effects in
the voice network. This module provides up to 127 milliseconds of tail length
in one way mode or up to 63 milliseconds of tail length in two way mode. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-7285-02 |
The 8-port CE Echo Cancellation Module is an extension module
for the 120 ohm 7470/7270/7670ESE 8-port T1/E1 CE Cards. The echo
cancellation module monitors ingress and egress speech in order to compute an
estimate of the undesired echo that may be present. This estimate is then
used to cancel echoes which accumulate due to hybrids and other effects in
the voice network. This module provides up to 127 milliseconds of tail length
in one way mode or up to 63 milliseconds of tail length in two way mode. This
assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-7571-01 |
Replacement air filters for the Peripheral Shelf 2 (90-4907-01);
Package of 10. |
REQUEST QUOTE |
| 90-7609-03 |
3600 FRE Release 4.3 software download key for FRE cards
90-1638-28 and lower with software generics P41X-XX-XX. For FRE card
90-1638-30, order 90-7609-04 FRE S/W DNLOAD KEY P424-H3. |
REQUEST QUOTE |
| 90-7662-01 |
3600 Downloadable Memory module. Used with 3600 Control Card
(90-0667-0x). Contains Release 8.0 Software. This module will be MD in
mid-2002. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label.+ |
REQUEST QUOTE |
| 90-7664-01 |
3600 peripheral Shelf Downloadable Memory module. Used with 3600
Control Card (90-0667-0x). Contains Release 8.0 Software. This module will be
MD in mid-2002. |
REQUEST QUOTE |
| 90-7665-01 |
3600 Switching Shelf Downloadable Memory module. Used with 3600
Control Card (90-0667-0x). Contains Release 8.0 Software. This module will be
MD in mid-2002. |
REQUEST QUOTE |
| 90-7670-01 |
Software download for Rel 2.0 of the 27LC-3 card. |
REQUEST QUOTE |
| 90-7694-01 |
This package provides
spares for parts that are currently shipp ed with the 7270 shelves. It
contains a power cord rubber feet PCMCIA card covers blank faceplates for
BITs Alarm and Control I/O card and 19in and 23in mounting rails and screws. |
REQUEST QUOTE |
| 90-7695-01 |
The Enhanced Traffic Management (ETM) module is an optional
module for the DS3-2, E3-2, OC3-2,STM1-2, OC3-2M and STM1-2M cell relay line
cards. It provides the Traffic Management features of the Titan ASIC,
including increased cell buffer size (1M cells), Weighted Fair per-VC Queuing
(WFQ) for all service categories, ingress and egress per-VC shaping, VP
Aggregation and ABR VS/VD and ER marking, in addition to the features and
functionality provided by the MTSM module. Requires a minimum of R4.3 software.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-7695-01 |
The Enhanced Traffic Management (ETM) module is an optional
module for the DS3-2, E3-2, OC3-2,STM1-2, OC3-2M and STM1-2M cell relay line
cards. It provides the Traffic Management features of the Titan ASIC,
including increased cell buffer size (1M cells), Weighted Fair per-VC Queuing
(WFQ) for all service categories, ingress and egress per-VC shaping, VP
Aggregation and ABR VS/VD and ER marking, in addition to the features and
functionality provided by the MTSM module. Requires a minimum of R4.3 software.
This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-7696-11 |
Four port 10/100 Base-T Ethernet card for 7470. Included is a 4
port 10BaseT/100BaseTX Electrical Interface MAU (90-8017-01). This card is
delivered with R4.3 software. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-7696-22 |
Four port 10/100 Base-T Ethernet card for 7470. This card
requires MAU 90-8017-01 (4 port 10BaseT/100BaseTX Electrical Interface MAU).
This card is delivered with R5.0 software. |
REQUEST QUOTE |
| 90-7696-32 |
Four port 10/100 Base-T Ethernet card for 7470. This card
requires MAU 90-8017-01 (4 port 10BaseT/100BaseTX Electrical Interface MAU). |
REQUEST QUOTE |
| 90-8017-01 |
Four port 10BaseT/100BaseTX Electrical Interface MAU. To be used
in conjunction with 90-7696-xx. |
REQUEST QUOTE |
| 90-8304-01 |
This optional module for the Control Card (90-4452-xx) provides
system timing which can be derived from any line interface or BITS input
(90-4451-01/03/04). This module has a wider capture range (+/- 50ppm) than
the Stratum 3 SSU. Note, however, that this is not a Stratum 3 clock source.
Stratum 3 timing requires part no. 90-6499-01. This part satisfies the
Australian regulatory requirement for CPE devices as stated in TS016. |
REQUEST QUOTE |
| 90-8305-01 |
This 3 meter cable connects one 16 port T1 or E1 Frame Relay
card (90-7277-xx) to one 16 port T1/E1 Distribution Panel (90-8307-X1). This
cable may also be used to connect one 16 port E1 Frame Relay card(90-7277-xx)
to two 8 port E1 75 ohm Distribution Panels(90-6398-X1). |
REQUEST QUOTE |
| 90-8307-01 |
This PRI RJ45 Distribution Panel provides 16 external RJ45
interfaces to the 100 ohm T1 or 120 ohm E1 twisted pair ports of a PRI card.
It may be used with PRI cards 90-4671-x1/x2, 90-2541-x1/x2, 90-2517-x1/x2,
and 90-7277-xx. The panel is a 1 vertical unit (VU) high rack-mountable
device. This panel is shipped with 1VU mid-mount brackets. This assembly
contains a Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-8308-01 |
This 1 meter cable connects one 16 port T1 or E1 Frame Relay
card (90-7277-xx) to two 8 port T1/E1 RJ-45 Distribution Panels(90-2543-X1). |
REQUEST QUOTE |
| 90-8477-01 |
This kit is used to upgrade an R4.3/5.0 Service Card-2 (CallP,
PNNI or Data Spooling card) to the enhanced Processor Module (ePM). Factory
shipments of R4.3 Service Card-2 and higher cards ship with the ePM installed
and do not require this upgrade kit. The kit contains an ePM (333 MHz PowerPC
755 module with 512M RAM), part number labels and instructions for
installation. |
REQUEST QUOTE |
| 90-8477-02 |
This kit is used to upgrade an R4.3 Control or Integrated
CallP/PNNI card to the enhanced Processor Module(ePM) and larger NOR Based
(256M) memory card. Factory shipments of R4.3 Control and Integrated
CallP/PNNI cards ship with the ePM installed, and with the larger memory card
included, and do not require this upgrade kit. The kit contains an ePM (333
MHz PowerPC 755 module with 512M RAM), 256M memory card, part number labels,
and instructions for installation. Note: The NOR-Based memory card is replaced
by a NAND-based memory card for later loadsets of R4.3. Be aware that this
part supplies the older NOR based memory card and that you should check with
Product Management before ordering this part. Field Notice FN1867 provides
more details. |
REQUEST QUOTE |
| 90-8477-11 |
This kit is used to upgrade an R5.0(or higher) Service Card-2
(CallP,PNNI or Data Spooling card) to the enhanced Processor Module (ePM).
Factory shipments of R5.0 Service Card-2 and higher cards ship with the ePM
installed and do not require this upgrade kit. The kit contains an ePM(333
MHz PowerPC 755 module with 512M RAM), part number labels and instructions
for installation. |
REQUEST QUOTE |
| 90-8477-12 |
This kit is used to upgrade an R5.0(or higher) Control or
Integrated CallP/PNNI card to the enhanced Processor Module(ePM) and
larger(256M) SanDisk. Factory shipments of R5.0 Control and Integrated
CallP/PNNI cards ship with the ePM installed, and with the larger SanDisk
included, and do not require this upgrade kit. The kit contains an ePM (333
MHz PowerPC 755 module with 512M RAM), 256M SanDisk, part number labels and
instructions for installation. |
REQUEST QUOTE |
| 90-8687-01 |
The quad OC3/STM1 IR UNI/NNI Card is a ATM interface card
operating at the SONET OC3 rate of 155 Mbps per port. The Intermediate Reach
(IR) single mode fiber optical interface has a total loss budget of 12db. The
quad OC3 card is compliant to the requirements of the ATM Forum UNI
Specification (Version 3.1) and the ATM Forum B-ICI Specification (Version
2.0). This card is also supported in ESE R2.0. This assembly contains a
Telcordia CLEI (Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-8687-02 |
The quad OC3/STM1 LR UNI/NNI Card is a ATM interface card
operating at the SONET OC3 rate of 155 Mbps per port. The Long Reach (LR)
single mode fiber optical interface has a total loss budget of 12db. The quad
OC3 card is compliant to the requirements of the ATM Forum UNI Specification
(Version 3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card
is also supported in ESE R2.0. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-8687-03 |
The quad OC3/STM1 MMF UNI/NNI Card is a ATM interface card
operating at the SONET OC3 rate of 155 Mbps per port. The multi-mode fiber
(MMF) optical interface has a typical rangeof 2km. The quad OC3 is compliant
to the requirements of the ATM Forum UNI Specification (Version 3.1) and the
ATM Forum B-ICI Specification (Version 2.0). This card is also supported in
ESE R2.0. This assembly contains a Telcordia CLEI (Common Language Equipment
Identifier) label. |
REQUEST QUOTE |
| 90-8687-04 |
The quad OC3/STM1 Electrical UNI/NNI Card is a ATM interface
card operating at the SONET OC3 rate of 155 Mbps per port. The electrical
interface is dual coaxial BNC connectors, with a range of 450 feet. The line
code is code mark inversion (CMI). The quad OC3 card is compliant to the
requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is also supported in ESE
R2.0. This assembly contains a Telcordia CLEI (Common Language Equipment Identifier)
label. |
REQUEST QUOTE |
| 90-8687-11 |
The quad OC3/STM1 IR UNI/NNI Card is a ATM interface card
operating at the SONET OC3 rate of 155 Mbps per port. The Intermediate Reach
(IR) single mode fiber optical interface has a total loss budget of 12db. The
quad OC3 card is compliant to the requirements of the ATM Forum UNI
Specification (Version 3.1) and the ATM Forum B-ICI Specification (Version
2.0). This card is also supported in ESE R2.0. |
REQUEST QUOTE |
| 90-8687-12 |
The quad OC3/STM1 LR UNI/NNI Card is a ATM interface card
operating at the SONET OC3 rate of 155 Mbps per port. The Long Reach (LR)
single mode fiber optical interface has a total loss budget of 12db. The quad
OC3 card is compliant to the requirements of the ATM Forum UNI Specification
(Version 3.1) and the ATM Forum B-ICI Specification (Version 2.0). This card
is also supported in ESE R2.0. |
REQUEST QUOTE |
| 90-8687-13 |
The quad OC3/STM1 MMF UNI/NNI Card is a ATM interface card
operating at the SONET OC3 rate of 155 Mbps per port. The multi-mode fiber
(MMF) optical interface has a typical rangeof 2km. The quad OC3 is compliant
to the requirements of the ATM Forum UNI Specification (Version 3.1) and the
ATM Forum B-ICI Specification (Version 2.0). This card is also supported in
ESE R2.0. |
REQUEST QUOTE |
| 90-8687-14 |
The quad OC3/STM1 Electrical UNI/NNI Card is a ATM interface
card operating at the SONET OC3 rate of 155 Mbps per port. The electrical
interface is dual coaxial BNC connectors, with a range of 450 feet. The line
code is code mark inversion (CMI). The quad OC3 card is compliant to the
requirements of the ATM Forum UNI Specification (Version 3.1) and the ATM
Forum B-ICI Specification (Version 2.0). This card is also supported in ESE
R2.0. |
REQUEST QUOTE |
| 90-8975-01 |
The R5.0 DS3 ATM Card is an 8 port card. Each port is both a UNI
and NNI DS3 ATM interface operating at 45Mbps. Each interface has dual coax
BNC connectors with a range of 450 feet. The DS3 card is fully compliant to
the mandatory requirements of the ATM Forum UNI specification (version 3.1)
and the ATM Forum B-ICI specification (version 2.0). This card is also
supported in ESE R2.0. This assembly contains a Telcordia CLEI (Common
Language Equipment Identifier) label. Requires Cable 90-9087-01 for ESE. |
REQUEST QUOTE |
| 90-8975-11 |
The 8 port DS3 ATM Card is an 8 port card. Each port is both a
UNI and NNI DS3 ATM interface operating at 45Mbps. Each interface has dual
coax BNC connectors with a range of 450 feet. The DS3 card is fully compliant
to the mandatory requirements of the ATM Forum UNI specification (version
3.1) and the ATM Forum B-ICI specification (version 2.0). This card is also
supported in ESE R2.0. |
REQUEST QUOTE |
| 90-8977-01 |
This kit is used to upgrade a Release 4.2 or R4.3 Integrated
CallP or Integrated CallP/PNNI card to an Integrated CallP/PNNI/Spooling card
in Release 5.0. Factory shipments of R5.0 Integrated CallP/PNNI/Spooling
cards ship with the ePM Installed, as well as with a larger (256M) SanDisk
and SRAM included,and do not require this upgrade kit. The kit contains an
ePM (333MHz PowerPC 755 module with 512M RAM), 256M SanDisk, 6M SRAM, part
number labels and instructions for |
REQUEST QUOTE |
| 90-8977-02 |
This kit is used to upgrade a 7470 Release 4.3-5.0 Integrated
CallP or Integrated CallP/PNNI card, or 7270 Release 5.0 control card to an
Integrated CallP/PNNI/Spooling card in Release 5.0. Also it is to be used to
upgrade a R2.0 7670 ESE ECC (90-8396-01) to support integrated data
spooling.Factory shipments of R5.0 Integrated CallP/PNNI/Spooling cards ship
with the SRAM included and do not require this upgrade kit. The kit contains
a 6M SRAM card, part number labels and instructions for installation. Note
for the 7470 that if the card to be upgraded does not use the ePM and larger
(256M) SanDisk, then the Integrated CallP or Integrated CallP/PNNI Upgrade to
Integrated CallP/PNNI/Data Spooling Kit(90-8977-01) should be used instead.
Note for the 7270 that if the card to be upgraded does not use the ePM and
larger (96M) SanDisk, then both the 7270 control card upgrade kit
(90-4452-13) and this upgrade kit are required.. |
REQUEST QUOTE |
| 90-8977-02 |
This kit is used to upgrade a 7470 Release 4.3-5.0 Integrated
CallP or Integrated CallP/PNNI card, or 7270 Release 5.0 control card to an
Integrated CallP/PNNI/Spooling card in Release 5.0. Also it is to be used to
upgrade a R2.0 7670 ESE ECC (90-8396-01) to support integrated data
spooling.Factory shipments of R5.0 Integrated CallP/PNNI/Spooling cards ship
with the SRAM included and do not require this upgrade kit. The kit contains
a 6M SRAM card, part number labels and instructions for installation. Note
for the 7470 that if the card to be upgraded does not use the ePM and larger
(256M) SanDisk, then the Integrated CallP or Integrated CallP/PNNI Upgrade to
Integrated CallP/PNNI/Data Spooling Kit(90-8977-01) should be used instead.
Note for the 7270 that if the card to be upgraded does not use the ePM and
larger (96M) SanDisk, then both the 7270 control card upgrade kit
(90-4452-13) and this upgrade kit are required.. |
REQUEST QUOTE |
| 90-9084-01 |
The drawer slide assembly is intended for use witthe 3612, 3624,
and 3630 rack mount systems(90-0575-68, 90-0411-57, 90-0411-58,
90-0412-52,90-0412-58, 90-2002-04, and 90-2003-03). This slide assembly
allows access to a system by pulling the chassis outward from an equipment
rack. |
REQUEST QUOTE |
| 90-9086-01 |
This cable is used to connect the 7470 8 port DS3 CR card to the
8 port 75 Ohm BNC distribution panel. |
REQUEST QUOTE |
| 90-9087-01 |
This cable is used to connect the 7670 ESE 8 port DS3 CR adapter
card to the 8 port 75 Ohm BNC distribution panel. |
REQUEST QUOTE |
| 90-9088-01 |
This distribution panel provides 8 external 75 Ohm BNC ports and
is to be used with the 7470 8 port DS3 CR card. The panel is a 1 vertical
unit (VU) high rack-mountable device. This assembly contains a Telcordia CLEI
(Common Language Equipment Identifier) label. |
REQUEST QUOTE |
| 90-9106-01 |
This cable is used to connect the quad OC3/STM1 IR/LR CR optical
card to a patch panel at the rear of the cabinet. |
REQUEST QUOTE |
| 90-9107-01 |
This cable is used to connect the quad OC3/STM1 MMF optical CR
card to a patch panel at the rear of the cabinet. |
REQUEST QUOTE |
| 90-9108-01 |
This cable is used to connect the quad OC3/STM1 Electrical CR
card to a patch panel at the rear of the cabinet. |
REQUEST QUOTE |
| 90-9135-01 |
This 90- level part number is used in conjunction with S/W
maintenance contracts to calculate and order s/w for the nodes within a
network over the period of the contract. |
REQUEST QUOTE |
| 90-9160-11 |
The Control to Integrated Control conversion kit is used to
convert a Control card to an Integrated Control card, enabling the card to
perform the PNNI and Call Processing functions provided by PNNI and CallP
cards in a common Control mode system. The kit contains part number labels,
password to enable the conversion and instructions for installation. The
software required for the conversion is part of the standard release load. |
REQUEST QUOTE |
| 90-9160-21 |
The Control to Integrated Control conversion kit is used to
convert a Control card to an Integrated Control card, enabling the card to
perform the PNNI and Call Processing functions provided by PNNI and CallP
cards in a common Control mode system. The kit contains part number labels,
password to enable the conversion and instructions for installation. The
software required for the conversion is part of the standard release load. |
REQUEST QUOTE |
| 90-9160-31 |
The Control to Integrated Control conversion kit is used to
convert a Control card to an Integrated Control card, enabling the card to
perform the PNNI and Call Processing functions provided by PNNI and CallP
cards in a common Control mode system. The kit contains part number labels,
password to enable the conversion and instructions for installation. The
software required for the conversion is part of the standard release load. |
REQUEST QUOTE |
| 90-9165-01 |
The High Speed Peripheral Shelf front cover is an optional
assembly for the High Speed Peripheral Shelf (90-2291-01). It is required for
European Union EMC Class B compliance. (Note that Class B compliance is
normally required for locations which are other than telecommunications
centre ; if the location is a telecommunications centre, then the HSPS front
cover may not be required.) The H/S Peripheral Shelf front cover is field
installable, and the kit consists of mounting brackets, shelf cover and instructions
for installation. The cover is perforated to allow all LEDs to be visible
through the perforations. Locking clips at the top of the cover allow the
cover to be removed to enable access to the OC12 line cards and FICs. |
REQUEST QUOTE |
| 90-9244-01 |
This is the 75 ohm Dual E1 Card version 3. This card is
backwards compatible with 90-0565-01 (Dual E1 2.048 Card)and 90-0568-01
(E1-75 OHM LIM MODULE). This card incorporates the LIMs on board so no
external LIM is required. This card is designed to replace the existing Dual
E1 card and has been designed to simplify ordering and sparing. |
REQUEST QUOTE |
| 90-9244-02 |
This is the 120 ohm Dual
E1 Card version 3. This card is backwards compatible with 90-0565-08 (Dual E1
2.048 Card)and 90-0568-02 (E1-120 OHM LIM MODULE). This card incorporates the
LIMs on board so no external LIM is required. This card is designed to
replace the existing Dual E1 card and has been designed to simplify ordering
and sparing. |
REQUEST QUOTE |
| 90-9253-01 |
This part is the NOR-based 96M SanDisk used in R4.2 (and lower)
Control and Integrated CallP/PNNI cards, and in all IP Service cards.
Permanently held at LA status. This kit can also be used to upgrade a
90-6184-01 ISC card to the 90-6184-12 ISC card level of functionality, and
replaces the ISC Card upgrade kit, 90-7736-01. |
REQUEST QUOTE |
| 90-9253-11 |
This part is the NOR-based 256M SanDisk used in R4.3 Control and
Integrated CallP/PNNI cards. Permanently held at LA status. |
REQUEST QUOTE |
| 90-9253-21 |
This part is the NAND-based 256M SanDisk used in R5.0 (and
higher)Control and Integrated CallP/PNNI cards. Permanently held at LA
status. |
REQUEST QUOTE |
| 90-9524-01 |
3600 Mainstreet AC Power Supply (87 to 264VAC). This part
provides AC power for the 3600 Mainstreet system and requires a power tray
(90-3669-11 single feed, or 90-3669-12 dual feed) to connect to the system.
The power supply can be used in pairs in load sharing mode to provide
redundant power. This power supply is designed to replace (90-2378-01). |
REQUEST QUOTE |
| 90-9524-02 |
3600 Mainstreet DC Power Supply (-48 TO 60VDC). This part
provides DC power for the 3600 Mainstreet system and requires a power tray
(90-3669-03) to connect to the system. The power supply can be used in pairs
in load sharing mode to provide redundant power. This power supply is
designed to replace (90-2378-02). |
REQUEST QUOTE |
| 90-9553-01 |
THE GSLC-12 IS A 12 PORT SHDSL LINE CARD. THIS LINE CARD IS
DESIGNED TO BE INSTALLED IN THE 3600 MAINSTREET PRODUCT LINE. THE LINE CARD
CAN CONNECT TO THE ALCATEL 3RD PARTY SHDSL NTU'S. |
REQUEST QUOTE |
| 90-9578-01 |
This part is the field replaceable power supply for the
Mainstreet family of IAD's. The power supply is for connecting to AC mains in
either 3612, 3624, or 3630 rackmount, wallmount, desk top systems. The
product comes with an integral ringer. The ringer frequency is selectable by
a jumper to operate at either 20hz or 25hz. |
REQUEST QUOTE |
| 90-9579-01 |
This part is the field replaceable power supply for the
Mainstreet family of IAD's. The power supply is for connecting to DC power in
either 3612,3624, or 3630 rackmount, wallmount, desk top systems. The ringer
is a seperate part. |
REQUEST QUOTE |
| 90-9634-01 |
This is the distribution panel to connect the 27LC2 (90-1184-05)
or 27LC3 (90-6396-01) to external circuits. The distribution panel connects
to the line card via(90-9635-01) 27LC/28LC DISTRIBUTION PANEL CABLE. The
27LC2 requires one cable per card and two cards may utilize a single
distribution panel. The 27LC3 require one cable and only one card may be
connected to the distribution panel. |
REQUEST QUOTE |
| 90-9634-02 |
This is the distribution panel to connect to either the 3600
GSLC-12 (90-9553-01) or 3600+ GSLC-16 (90-9552-01) or 28LC (90-4927-01). The
distribution panel connects to the line card via cable 27LC/28LC/GSLC
Distribution Panel Cable (90-9635-01). The 28LC (90-4927-01) requires one
cable per card and two cards may be connected to a single distribution panel.
The GSLC-12 , and GSLC-16 require one cable and only one card may be
connected to the distribution panel. |
REQUEST QUOTE |
| 90-9635-01 |
This cable is used to connect 27LC2, 27LC3, to (90-9634-01)
27LCx Distribution Panel, or 28LC, GSLC-12, and GSLC-16 to the (90-9634-02)
28LC/GSLC Distribution Panel. |
REQUEST QUOTE |
| 90-9711-01 |
This cable kit is required when connecting 90-5946-01 (Ring
Generator PSU) internally in a MainStreet Power Tray (90-3669-xx). This kit
is intended for the following revisions of power tray; 90-3669-03/K,
90-3669-11/B and 90-3669-12/B. The MainStreet power tray has been updated to
incorporate new functionality and the new cable kit is required. |
REQUEST QUOTE |
| 94-1074-01 |
The R4.3 Enhanced Traffic Management OC3-2M IR bundle consists
of an OC3-2M IR UNI/NNI Card with CPU-2 line card(90-4905-1A) and an Enhanced
Traffic Management (ETM) module (90-7695-01). |
REQUEST QUOTE |
| 94-1074-02 |
The R4.3 Enhanced Traffic Management OC3-2M LR bundle consists
of an OC3-2M LR UNI/NNI Card with CPU-2 line card (90-4905-1B) and an
Enhanced Traffic Management (ETM) module (90-7695-01). |
REQUEST QUOTE |
| 94-1074-03 |
The R4.3 Enhanced Traffic Management OC3-2M MMF bundle consists
of an OC3-2M MMF UNI/NNI Card with CPU-2 line card (90-4905-1C) and an
Enhanced Traffic Management (ETM) module (90-7695-01). |
REQUEST QUOTE |
| 94-1075-01 |
The R5.0 Enhanced Traffic Management OC3-2M IR bundle consists
of an OC3-2M IR UNI/NNI Card with CPU-2 line card(90-4905-2A) and an Enhanced
Traffic Management (ETM) module (90-7695-01). This bundle can also be used
with ESE Release 2.0. |
REQUEST QUOTE |
| 94-1075-02 |
The R5.0 Enhanced Traffic Management OC3-2M LR bundle consists
of an OC3-2M LR UNI/NNI Card with CPU-2 line card (90-4905-2B) and an
Enhanced Traffic Management (ETM) module (90-7695-01). This bundle can also
be used with ESE Release 2.0. |
REQUEST QUOTE |
| 94-1075-03 |
The R5.0 Enhanced Traffic Management OC3-2M MMF bundle consists
of an OC3-2M MMF UNI/NNI Card with CPU-2 line card (90-4905-2C) and an
Enhanced Traffic Management (ETM) module (90-7695-01). This bundle can also
be used with ESE Release 2.0. |
REQUEST QUOTE |
| 94-1075-11 |
The R6.0 Enhanced Traffic Management OC3-2M IR bundle consists
of an OC3-2M IR UNI/NNI Card with CPU-2 line card (90-4905-3A) and an
Enhanced Traffic Management (ETM) module (90-7695-01). This bundle can also
be used with ESE Release 2.2. |
REQUEST QUOTE |
| 94-1075-12 |
The R6.0 Enhanced Traffic Management OC3-2M LR bundle consists
of an OC3-2M LR UNI/NNI Card with CPU-2 line card (90-4905-3B) and an
Enhanced Traffic Management (ETM) module (90-7695-01). This bundle can also
be used with ESE Release 2.2. |
REQUEST QUOTE |
| 94-1075-13 |
The R6.0 Enhanced Traffic Management OC3-2M MMF bundle consists
of an OC3-2M MMF UNI/NNI Card with CPU-2 line card (90-4905-3C) and an
Enhanced Traffic Management (ETM) module (90-7695-01). This bundle can also
be used with ESE Release 2.2. |
REQUEST QUOTE |
| 94-1076-01 |
The R4.3 Enhanced Traffic Management STM1-2M IR bundle consists
of an STM1-2M IR UNI/NNI Card with CPU-2 (90-4909-1A) and an Enhanced Traffic
Management (ETM) module (90-7695-01). |
REQUEST QUOTE |
| 94-1076-02 |
The R4.3 Enhanced Traffic Management STM1-2M LR bundle consists
of an STM1-2M LR UNI/NNI Card with CPU-2 (90-4909-1B) and an Enhanced Traffic
Management (ETM) module (90-7695-01). |
REQUEST QUOTE |
| 94-1076-03 |
The R4.3 Enhanced Traffic Management STM1-2M MMF bundle consists
of an STM1-2M MMF UNI/NNI Card with CPU-2 (90-4909-1C) and an Enhanced
Traffic Management (ETM) module (90-7695-01). |
REQUEST QUOTE |
| 94-1077-01 |
The R5.0 Enhanced Traffic Management STM1-2M IR bundle consists
of an STM1-2M IR UNI/NNI Card with CPU-2 (90-4909-2A) and an Enhanced Traffic
Management (ETM) module (90-7695-01). This bundle can also be used with ESE
Release 2.0. |
REQUEST QUOTE |
| 94-1077-02 |
The R5.0 Enhanced Traffic Management STM1-2M LR bundle consists
of an STM1-1M LR UNI/NI Card with CPU-2 (90-4909-2B) and an Enhanced Traffic
Management (ETM) module (90-7695-01). This bundle can also be used with ESE
Release 2.0. |
REQUEST QUOTE |
| 94-1077-03 |
The R5.0 Enhanced Traffic Management STM1-2M MMF bundle consists
of an STM1-2M MMF UNI/NNI Card with CPU-2 (90-4909-2C) and an Enhanced
Traffic Management (ETM) module (90-7695-01). This bundle can also be used
with ESE Release 2.0. |
REQUEST QUOTE |
| 94-1077-11 |
The R6.0 Enhanced Traffic Management STM1-2M IR bundle consists
of an STM1-2M IR UNI/NNI Card with CPU-2 (90-4909-2A) and an Enhanced Traffic
Management (ETM) module (90-7695-01). This bundle can also be used with ESE
Release 2.2. |
REQUEST QUOTE |
| 94-1077-12 |
The R6.0 Enhanced Traffic Management STM1-2M LR bundle consists
of an STM1-1M LR UNI/NI Card with CPU-2 (90-4909-2B) and an Enhanced Traffic
Management (ETM) module (90-7695-01). This bundle can also be used with ESE
Release 2.2. |
REQUEST QUOTE |
| 94-1077-13 |
The R6.0 Enhanced Traffic Management STM1-2M MMF bundle consists
of an STM1-2M MMF UNI/NNI Card with CPU-2 (90-4909-2C) and an Enhanced
Traffic Management (ETM) module (90-7695-01). This bundle can also be used
with ESE Release 2.2. |
REQUEST QUOTE |
|
|