Network 9000 Modular Console and Alarm Management

The Network 9000 chassis family provides support for a wide range of networking interface modules that are interchangeable between 3-slot, 6-slot and 15-slot chassis.
The Network 9000 provides network administrators with the flexibility to create application-specific configurations.

To meet the critical and wide-ranging roles that hubs serve in today's networking infrastructures, the Network 9000 has been engineered to provide redundancy and fault tolerance in critical applications. Ease of maintenance features such as hot swapping of components and automatic module reconfiguration minimize network downtime. A range of power and density options meets the requirements of all types and sizes of networks.

Midplane Architecture
The midplane architecture of the Network 9000 eliminates the restrictions of traditional backplane-based hubs. Network administrators can mix and match I/O modules with processor modules. Processor and I/O modules connect at the midplane of the chassis and a pair typically occupies one full slot. The midplane design provides greater flexibility in the selection of connectors and I/O options, ease of maintenance and module replacements, simplified sparing, and exceptional flexibility.

The Network 9000 midplane supports three 10-Mbps shared Ethernet segments. Each shared media network is available from every slot. The midplane also includes a local management bus connecting to all installed modules.

Reliability and Maintenance
The Network 9000 is engineered with a number of features that enhance reliability. Hot Swapping - Modules, most redundant power supplies, and cooling fans can be replaced without powering down the unit or interrupting the network. When modules are swapped, the new module is automatically configured with the parameters of its predecessor.

Cooling Design - Network 9000 chassis fans provide more than enough cooling capacity so that the unit can operate even if one or more fans fail. Fans are mounted on slide-in assemblies for quick replacement.

LEDs - Status LEDs on the front of each processor module allow a network administrator to quickly determine the status of the processor module and the interface connections on its companion I/O module. Distributed management - The Switch Plane contains a dedicated management bus to which all modules in the chassis are connected. SNMP and RMON agents reside on the individual modules. Through the management bus, a single processor module can provide management access to all other components in the chassis - even if the network is down.

Software loading - Multiple software loading options ensure that network administrators can load software to Network 9000 modules from multiple sources, a useful feature for performing software upgrades and for rebooting after a failure or module swap. Processor modules also support loading from a network-based load server such as a workstation-based host. The network administrator can load software images over local or wide area networks, allowing centralized distribution of updates and ensuring that all units use the correct software.

Modular Console Server, Alarm Management
Terminal Server Modules
Model Description Order
N9-000-723 Access Server I/O module, 20 ports via RJ-45 connectors. Supports concurrent hardware modem control and hardware flow control. newbri3.gif
N9-000-724 Access Server I/O module, 24 ports via three Telco connectors. newbri3.gif
N9-720-000-4 Access Server processor module, 4 MB RAM. newbri3.gif
N9-720-000-6 Access Server processor, 6 MB RAM. newbri3.gif
Ethernet Management Processor Modules
N9-210-000 Management processor module. newbri3.gif
Ethernet Concentrator I/O Modules
N9-000-203A 20-port 10Base-T Enhanced I/O module. Integrated RJ-45 connectors. newbri3.gif
Accessories
NETWORK 9000: Chassis-Based Solutions
Chassis
N9-9006-021 6-slot chassis including AC controller module and cooling fans. Requires AC power supply. newbri3.gif
N9-9106-021 6-slot chassis with Switch Plane including AC controller module and cooling fans. Requires AC power supply. newbri3.gif
N9-9115-021 15-slot chassis with Switch Plane including AC controller module and cooling fans. Requires AC power supply. newbri3.gif
N9-9106-022 6-slot chassis with Switch Plane including DC controller module and cooling fans. Requires DC power supply. newbri3.gif
N9-9006-022 6-slot chassis including DC controller module and cooling fans. Requires DC power supply. newbri3.gif
N9-9115-022 15-slot chassis with Switch Plane including 2 redundant AC controller modules. Requires AC power supply. newbri3.gif
N9-9115-023 15-slot chassis with Switch Plane including DC controller module and cooling fans. Requires DC power supply. newbri3.gif
N9-9115-024 15-slot chassis with Switch Plane including 2 redundant DC controller modules. Requires DC power supply. newbri3.gif
Power Supplies
N9-020-119 Spare AC controller module. newbri3.gif
N9-020-119D Spare 48-Volt DC controller module. newbri3.gif
N9-020-119DR Spare redundant DC controller module. For use with N9-9015 or N9-9115 only. Customer must provide the Ethernet address for the redundant module at the time the order is placed. newbri3.gif
N9-020-119R Spare redundant AC controller module. For use with N9-9015 or N9-9115 only. Customer must provide the Ethernet address for the redundant module at the time the order is placed. newbri3.gif
N9-125-020 Unmanaged AC power supply. newbri3.gif
N9-130-020 Managed AC power supply. newbri3.gif
N9-150-020 Managed DC power supply. newbri3.gif
Cables and Adapters
MX-151-3039 V.35 cable, male 34 pin to male 35 pin. 15 feet. newbri3.gif
MX-151-3148 V.35 male to V.35 male cable, 15 feet. Supports RING on V.35 pin L. newbri3.gif
MX-350-0369 UTP Category 5 cable with RJ-45 connectors, straight-through cable. Use with 10 Mbps-155 Mbps applications, including 10Base-T, 100Base-T, TP-PMD and ATM. 10 feet. newbri3.gif
Miscellaneous
N9-000-003 Cable management ears, 6-slot chassis. newbri3.gif
N9-000-004 Cable management ears, 15-slot chassis. newbri3.gif
N9-000-006 Blank panel, front, 1-slot. newbri3.gif
N9-000-007 Blank panel, rear, 1-slot. newbri3.gif
N9-000-106 Spare fan module. newbri3.gif
Upgrades
Memory Upgrades
N9-500-8183 4 MB SIMM field upgrade for 401 and 402 processor modules. newbri3.gif
Flash Cards
MX-440-0287 4 MB Wrap Series 2 Flash Card. No software. newbri3.gif
Internetworking & Media Products Software Kits
MED-IM-08 Flash memory card, 4MB, for 401/4xx Router. Branch image only. newbri3.gif
MED-IM-10 Flash memory card, 4MB, for Ethernet Management Processor. newbri3.gif
MED-IM-11 CD-ROM kit. Master product software kit.Includes all internetworking and media software and documentation. newbri3.gif
MED-IM-16 Flash memory card, 4 MB, for the 401/4xx router and 210/211 Management Processor. Branch image only. newbri3.gif
MED-IM-19 4-MB flash memory card for the Network 3000 with regional image including IP, IPX, AppleTalk, Frame Relay, PPP, Spanning Tree Bridging, ISDN, DECnet. Requires 8 MB of main memory; for Network 3000 only, not compatible with ROUTERUNNER products. newbri3.gif
MED-IM-20 Flash memory card, 4 MB, for the Network 9000 with regional image. newbri3.gif
MED-IM-21 Flash memory card, 4 MB, for the Network 9000 with enterprise image. newbri3.gif
Frame Relay Software
MX-420-0617 Frame Relay Option. User-installable software key to enable Frame Relay interface on Bridge/Router products.Not required on the Network 3000 and ROUTERUNNER products. newbri3.gif
X.25 Software
MX-420-0824 X.25 Router Link Option. User-Installable software key to enable X.25 as a Bridge/Router link option on all bridge/router products except the Network 3000. Router should have at least 5 MB of memory. newbri3.gif